Most-cited articles · 2023

The 50 most-cited articles in Review of Scientific Instruments, 2023

Ranked by OpenAlex citation count on 29 October 2026, out of 884 eligible articles Review of Scientific Instruments published in 2023. Ranks are frozen; this page will not change. Number one, with 87 citations: A survey on the mechanical design for piezo-actuated compliant micro-positioning stages.

Cohort
884 articles
Listed
Top 50 (5.7%)
Open access
28 of 50
Snapshot
2026-10-29

The most-cited articles from Review of Scientific Instruments in 2023 cluster around a few themes: instrumentation for high energy density and inertial confinement fusion research, precision motion and mechanical design, and advanced detector and readout systems for physics experiments. The top paper, by Bingxiao Ding, Xuan Li, Chenglin Li and colleagues, is a survey on mechanical design for piezo-actuated compliant micro-positioning stages with 87 citations. Other highly cited works describe diagnostics such as velocity interferometers, neutron time-of-flight detectors, and X-ray phase contrast imaging, alongside cryogenic and microwave readout electronics.

For readers, the list offers a snapshot of the instrumentation topics that attracted the most citations in the journal that year. It shows which methods and devices were most frequently referenced in the literature, spanning fusion diagnostics, precision engineering, and detector development.

Introduction written from the titles and abstracts on this list. Every figure below is the source.

Ask about these papers

Grounded in this list only, with sources.

3 of 3 free questions left today, no account needed
  1. 1
    top 0.2%

    A survey on the mechanical design for piezo-actuated compliant micro-positioning stages

    Bingxiao Ding, Xuan Li, Chenglin Li, Yangmin Li, Shih‐Chi Chen

    87 citationsdoi:10.1063/5.0162246OpenAlex

    Show abstract

    This paper presents a comprehensive review of mechanical design and synthesis methods for piezo-actuated compliant micro-positioning stages, which play an important role in areas where high precision motion is required, including bio-robotics, precision manufacturing, automation, and aerospace. Unlike conventional rigid-link mechanisms, the motion of compliant mechanisms is realized by using flexible elements, whereby deformation requires no lubrication while achieving high movement accuracy without friction. As compliant mechanisms differ significantly from traditional rigid mechanisms, recent research has focused on investigating various technologies and approaches to address challenges in the flexure-based micro-positioning stage in the aspects of synthesis, analysis, material, fabrication, and actuation. In this paper, we reviewed the main concepts and key advances in the mechanical design of compliant piezo-actuated micro-positioning stages, with a particular focus on flexure design, kineto-static modeling, actuators, material selection, and functional mechanisms including…

  2. 2
    top 0.3%

    Dark matter axion search using a Josephson Traveling wave parametric amplifier

    C. Bartram, T. Braine, Raphael Cervantes, Nicole Crisosto, N. Du and 25 more

    80 citationsOpen accessdoi:10.1063/5.0122907OpenAlex

    Show abstract

    We describe the first implementation of a Josephson Traveling Wave Parametric Amplifier (JTWPA) in an axion dark matter search. The operation of the JTWPA for a period of about two weeks achieved sensitivity to axion-like particle dark matter with axion-photon couplings above 10-13 Ge V-1 over a narrow range of axion masses centered around 19.84 µeV by tuning the resonant frequency of the cavity over the frequency range of 4796.7-4799.5 MHz. The JTWPA was operated in the insert of the axion dark matter experiment as part of an independent receiver chain that was attached to a 0.56-l cavity. The ability of the JTWPA to deliver high gain over a wide (3 GHz) bandwidth has engendered interest from those aiming to perform broadband axion searches, a longstanding goal in this field.

  3. 3
    top 0.4%

    Imaging velocity interferometer system for any reflector (VISAR) diagnostics for high energy density sciences

    Peter M. Celliers, Marius Millot

    72 citationsOpen accessdoi:10.1063/5.0123439OpenAlex

    Show abstract

    Two variants of optical imaging velocimetry, specifically the one-dimensional streaked line-imaging and the two-dimensional time-resolved area-imaging versions of the Velocity Interferometer System for Any Reflector (VISAR), have become important diagnostics in high energy density sciences, including inertial confinement fusion and dynamic compression of condensed matter. Here, we give a brief review of the historical development of these techniques, then describe the current implementations at major high energy density (HED) facilities worldwide, including the OMEGA Laser Facility and the National Ignition Facility. We illustrate the versatility and power of these techniques by reviewing diverse applications of imaging VISARs for gas-gun and laser-driven dynamic compression experiments for materials science, shock physics, condensed matter physics, chemical physics, plasma physics, planetary science and astronomy, as well as a broad range of HED experiments and laser-driven inertial confinement fusion research.

  4. 4
    top 0.5%

    Design of the shattered pellet injection system for ASDEX Upgrade

    M. Dibon, P. de Marné, G. Papp, Igor Vinyar, Alexander Ya. Lukin and 9 more

    49 citationsOpen access (CC-BY)doi:10.1063/5.0141799OpenAlex

    Show abstract

    A new shattered pellet injection system was designed and built to perform disruption mitigation experiments on ASDEX Upgrade. The system can inject pellets with diameters of 1, 2, 4, or 8 mm with variable lengths over a range of L/D ratios of ∼0.5-1.5. By using helium or deuterium as propellant gas, the pellets can be accelerated to speeds between 60 and 750 m/s. The velocity range slightly depends on the pellet mass. The injection system is capable of preparing three pellets in separate barrels at the same time. Once accelerated by the propellant gas pulse, the pellets travel through one of three parallel flight tubes. Each flight tube is separated into three sections with increasing diameters of 12, 14, and 16 mm. Two gaps between the sections allow for removal of the propellant gas by expansion into two separate expansions tanks (0.3 and 0.035 m3), pellet observation in the first gap and the torus gate valve in the second. Each flight tube end is equipped with an exchangeable shatter head with different shatter angles, square or circular cross-section, and different lengths. The…

  5. 5
    top 0.6%

    Integrating test device and method for creep failure and ultrasonic response of methane hydrate-bearing sediments

    Qiaobo Hu, Yanlong Li, Xiaofeng Sun, Mingtao Chen, Qingtao Bu and 1 more

    44 citationsdoi:10.1063/5.0133198OpenAlex

    Show abstract

    Clarifying the creep behaviors of hydrate-bearing sediment (HBS) under long-term loading is crucial for evaluating reservoir stability during hydrate exploitation. Figuring out a way of characterizing deformation behaviors and their geophysical responses to HBS is the basis for modeling creep behaviors. In this study, we propose a novel device to test time-dependent deformation and the ultrasonic response of HBS under high-pressure and low-temperature. The experimental device consists of a high-pressure chamber, an axial-load control system, a confining pressure system, a pore pressure system, a back-pressure system, and a data collection system. This testing assembly allows temperature regulation and independent control of four pressures, e.g., confining pressure, pore pressure, back pressure, and axial loading. Columned artificial HBS samples, with a diameter of 39 mm and a height of 120 mm, can be synthesized in this device. Afterward, in situ creep experiments can be achieved by applying stable confining pressure and axial load, together with geophysical signals acquisition.…

  6. 6
    top 0.7%

    Invited article: X-ray phase contrast imaging in inertial confinement fusion and high energy density research

    David S. Montgomery

    39 citationsOpen access (CC-BY)doi:10.1063/5.0127497OpenAlex

    Show abstract

    X-ray phase contrast imaging (XPCI) provides enhanced image contrast beyond absorption-based x-ray imaging alone due to refraction and diffraction from gradients in the object material density. It is sensitive to small variations in density, such as internal voids, cracks, grains, defects, and material flow, as well as to stronger density variations such as from a shock wave. Beyond its initial use in biology and materials science, XPCI is now routinely used in inertial confinement fusion (ICF) and high energy density (HED) research, first to characterize ICF capsules and targets, and later applied in dynamic experiments, where coherent x-ray sources, ultrafast x-ray pulses, and high temporal and spatial resolution are required. In this Review article, XPCI image formation theory is presented, its diverse use in ICF and HED research is discussed, the unique requirements for ultrafast XPCI imaging are given, as well as current challenges and issues in its use.

  7. 7
    top 0.8%

    SLAC microresonator RF (SMuRF) electronics: A tone-tracking readout system for superconducting microwave resonator arrays

    Cyndia Yu, Zeeshan Ahmed, J. Frisch, Shawn W. Henderson, Maximiliano Silva-Feaver and 20 more

    39 citationsOpen accessdoi:10.1063/5.0125084OpenAlex

    Show abstract

    We describe the newest generation of the SLAC Microresonator RF (SMuRF) electronics, a warm digital control and readout system for microwave-frequency resonator-based cryogenic detector and multiplexer systems, such as microwave superconducting quantum interference device multiplexers (μmux) or microwave kinetic inductance detectors. Ultra-sensitive measurements in particle physics and astronomy increasingly rely on large arrays of cryogenic sensors, which in turn necessitate highly multiplexed readout and accompanying room-temperature electronics. Microwave-frequency resonators are a popular tool for cryogenic multiplexing, with the potential to multiplex thousands of detector channels on one readout line. The SMuRF system provides the capability for reading out up to 3328 channels across a 4-8 GHz bandwidth. Notably, the SMuRF system is unique in its implementation of a closed-loop tone-tracking algorithm that minimizes RF power transmitted to the cold amplifier, substantially relaxing system linearity requirements and effective noise from intermodulation products. Here, we…

  8. 8
    top 1%

    A sub-2 Kelvin cryogenic magneto-terahertz scattering-type scanning near-field optical microscope (cm-THz-sSNOM)

    Richard H. J. Kim, J.-M. Park, Samuel Haeuser, Liang Luo, Jigang Wang

    36 citationsOpen accessdoi:10.1063/5.0130680OpenAlex

    Show abstract

    We have developed a versatile near-field microscopy platform that can operate at high magnetic fields and below liquid-helium temperatures. We use this platform to demonstrate an extreme terahertz (THz) nanoscope operation and to obtain the first cryogenic magneto-THz time-domain nano-spectroscopy/imaging at temperatures as low as 1.8 K, magnetic fields of up to 5 T, and with operation of 0-2 THz. Our Cryogenic Magneto-Terahertz Scattering-type Scanning Near-field Optical Microscope (or cm-THz-sSNOM) instrument is comprised of three main equipment: (i) a 5 T split pair magnetic cryostat with a custom made insert, (ii) a custom sSNOM instrument capable of accepting ultrafast THz excitation, and (iii) a MHz repetition rate, femtosecond laser amplifier for broadband THz pulse generation and sensitive detection. We apply the cm-THz-sSNOM to obtain proof of principle measurements of superconductors and topological semimetals. The new capabilities demonstrated break grounds for studying quantum materials that require an extreme environment of cryogenic operation and/or applied magnetic…

  9. 9
    top 1.1%

    Neutron time of flight (nToF) detectors for inertial fusion experiments

    A. S. Moore, D. J. Schlossberg, Brian Appelbe, Gordon A. Chandler, Aidan Crilly and 9 more

    35 citationsdoi:10.1063/5.0133655OpenAlex

    Show abstract

    Neutrons generated in Inertial Confinement Fusion (ICF) experiments provide valuable information to interpret the conditions reached in the plasma. The neutron time-of-flight (nToF) technique is well suited for measuring the neutron energy spectrum due to the short time (100 ps) over which neutrons are typically emitted in ICF experiments. By locating detectors 10s of meters from the source, the neutron energy spectrum can be measured to high precision. We present a contextual review of the current state of the art in nToF detectors at ICF facilities in the United States, outlining the physics that can be measured, the detector technologies currently deployed and analysis techniques used.

  10. 10
    top 1.2%

    Commissioning of the novel Continuous Angle Multi-energy Analysis spectrometer at the Paul Scherrer Institut

    Jakob Lass, H. Jacobsen, Kristine M. L. Krighaar, Dieter Graf, Felix Groitl and 16 more

    32 citationsOpen access (CC-BY)doi:10.1063/5.0128226OpenAlex

    Show abstract

    We report on the commissioning results of the cold neutron multiplexing secondary spectrometer CAMEA (Continuous Angle Multi-Energy Analysis) at the Swiss Spallation Neutron Source at the Paul Scherrer Institut, Switzerland. CAMEA is optimized for efficient data acquisition of scattered neutrons in the horizontal scattering plane, allowing for detailed and rapid mapping of low-energy excitations under extreme sample environment conditions.

  11. 11
    top 1.3%

    Gamma-ray measurements for inertial confinement fusion applications

    Yongho Kim, Hans W. Herrmann

    28 citationsOpen access (CC-BY)doi:10.1063/5.0126969OpenAlex

    Show abstract

    High-energy γ rays generated from inertial confinement fusion (ICF) experiments have become an important signature for studying the dynamics of implosion processes. Due to their high-energy and penetrating nature, γ rays are the most unperturbed fusion products, which can preserve the original birth information of the fusion process. Fusion γ rays provide a direct measure of nuclear reaction rates (unlike x rays) without being compromised by Doppler spreading (unlike neutrons). However, unambiguous γ-ray measurements for ICF study further required a decade-long period of technological development, which included a deepening understanding of fusion γ-ray characteristics and innovations in instrument performance. This review article introduces the production mechanism of the prompt and secondary γ rays and various ICF performance parameters (e.g., bang time and burn width), which can be derived from γ-ray measurement. A technical overview will be followed by summarizing γ-ray detectors fielded or proposed, especially for high-yield ICF experiments at the Omega Laser Facility and…

  12. 12
    top 1.4%

    Tabletop extreme ultraviolet reflectometer for quantitative nanoscale reflectometry, scatterometry, and imaging

    Yuka Esashi, Nicholas W. Jenkins, Yunzhe Shao, Justin M. Shaw, Seungbeom Park and 3 more

    26 citationsdoi:10.1063/5.0175860OpenAlex

    Show abstract

    Imaging using coherent extreme-ultraviolet (EUV) light provides exceptional capabilities for the characterization of the composition and geometry of nanostructures by probing with high spatial resolution and elemental specificity. We present a multi-modal tabletop EUV imaging reflectometer for high-fidelity metrology of nanostructures. The reflectometer is capable of measurements in three distinct modes: intensity reflectometry, scatterometry, and imaging reflectometry, where each mode addresses different nanostructure characterization challenges. We demonstrate the system's unique ability to quantitatively and non-destructively measure the geometry and composition of nanostructures with tens of square microns field of view and sub-nanometer precision. Parameters such as surface and line edge roughness, density, nanostructure linewidth, and profile, as well as depth-resolved composition, can be quantitatively determined. The results highlight the applicability of EUV metrology to address a wide range of semiconductor and materials science challenges.

  13. 13
    top 1.5%

    Analysis of a UV photocatalytic oxidation-based disinfection system for hydroxyl radicals, negative air ions generation and their impact on inactivation of pathogenic micro-organisms

    Kiran Ahlawat, Ramavtar Jangra, Ambar Ish, Ambesh Dixit, Deepak Fulwani and 2 more

    26 citationsdoi:10.1063/5.0151619OpenAlex

    Show abstract

    This work presents a large-scale surface disinfection system, which has a unique lantern arrangement of ultraviolet-C (UV-C) light (254 nm) in conjunction with nanotechnology in a protective biosafety environment. Shadow regions are best dealt in this system by the generation of hydroxyl radicals (•OH) and negative air ions at sites where UV light cannot penetrate. More than 35 000 negative air ions/cm3 along with •OH were produced continuously in the disinfection chamber through the advanced photocatalytic oxidation process [UV-C + titanium dioxide (TiO2)]. The arrangement has been made to provide an optimized UV irradiation (∼2 mW/cm2) throughout the disinfection system. In order to distinguish between effects arising from (i) the action of UV dose alone and (ii) the action of UV dose along with •OH and negative air ions, E. coli and P. aeruginosa were chosen for bacterial testing and two interventions were made. The first intervention involved placing only UV lamps in the disinfection chamber to see the effect of only UV dose on bacterial inactivation efficiency. The second…

  14. 14
    top 1.6%

    Design and implementation of a prototype infrared video bolometer (IRVB) in MAST Upgrade

    F. Federici, Matthew L. Reinke, B. Lipschultz, Andrew J. Thornton, J. Harrison and 3 more

    26 citationsOpen access (CC-BY)doi:10.1063/5.0128768OpenAlex

    Show abstract

    A prototype infrared video bolometer (IRVB) was successfully deployed in the Mega Ampere Spherical Tokamak Upgrade (MAST Upgrade or MAST-U), the first deployment of such a diagnostic in a spherical tokamak. The IRVB was designed to study the radiation around the lower x-point, another first in tokamaks, and has the potential to estimate emissivity profiles with spatial resolution beyond what is achievable with resistive bolometry. The system was fully characterized prior to installation on MAST-U, and the results are summarized here. After installation, it was verified that the actual measurement geometry in the tokamak qualitatively matches the design; this is a particularly difficult process for bolometers and was done using specific features of the plasma itself. The installed IRVB measurements are consistent both with observations from other diagnostics, including magnetic reconstruction, visible light cameras, and resistive bolometry, as well as with the IRVB-designed view. Early results show that with conventional divertor geometry and only intrinsic impurities (for example, C…

  15. 15
    top 1.7%

    High resolution spatially extended 1D laser scattering diagnostics using volume Bragg grating notch filters

    Junhwi Bak, Jean Luis Suazo Betancourt, Anuj Rekhy, Amirhossein Abbasszadehrad, Richard B. Miles and 2 more

    26 citationsOpen accessdoi:10.1063/5.0121436OpenAlex

    Show abstract

    Laser light scattering systems with volume Bragg grating (VBG) filters, which act as spectral/angular filters, have often been used as a point measurement technique, with spatial resolution as low as a few hundred μm, defined by the beam waist. In this work, we demonstrate how VBG filters can be leveraged for spatially resolved measurements with several μm resolution over a few millimeters along the beam propagation axis. The rejection ring, as determined by the angular acceptance criteria of the filter, is derived analytically, and the use of the ring for 1D laser line rejection is explained. For the example cases presented,i.e., for a focused probe beam waist with a diameter of ∼150 μm, the rejection ring can provide resolution up to several millimeter length along the beam propagation axis for a 1D measurement, which is also tunable. Additionally, methods to further extend the measurable region are proposed and demonstrated, using a collimation lens with a different focal length or using multiple VBG filters. The latter case can minimize the scattering signal loss, without the…

  16. 16
    top 1.9%

    Realization of high-dynamic-range broadband magnetic-field sensing with ensemble nitrogen-vacancy centers in diamond

    Cao Wang, Qihui Liu, Yuqiang Hu, Fei Xie, Krishangi Krishna and 7 more

    26 citationsOpen accessdoi:10.1063/5.0089908OpenAlex

    Show abstract

    We present a new magnetometry method integrating an ensemble of nitrogen-vacancy (NV) centers in a single-crystal diamond with an extended dynamic range for monitoring a fast changing magnetic-field. The NV-center spin resonance frequency is tracked using a closed-loop frequency locked technique with fast frequency hopping to achieve a 10 kHz measurement bandwidth, thus allowing for the detection of fast changing magnetic signals up to 0.723 T/s. This technique exhibits an extended dynamic range subjected to the working bandwidth of the microwave source. This extended dynamic range can reach up to 4.3 mT, which is 86 times broader than the intrinsic dynamic range. The essential components for NV spin control and signal processing, such as signal generation, microwave frequency control, data processing, and readout, are integrated in a board-level system. With this platform, we demonstrate a broadband magnetometry with an optimized sensitivity of 4.2 nT Hz−1/2. This magnetometry method has the potential to be implemented in a multichannel frequency locked vector magnetometer suitable…

  17. 17
    top 2%

    Modeling and analysis of a metal rubber vibration isolation system considering the nonlinear stiffness characteristics

    Yujun Liu, Jing Liu, Guang Pan, Qiaogao Huang

    24 citationsdoi:10.1063/5.0118415OpenAlex

    Show abstract

    In this study, the complete design process of a metal rubber isolator using a numerical method applied in automobile underwater gliders (AUGs) is researched. A ring-like metal rubber isolator that has the potential to reduce the vibration of the AUGs is proposed. In the numerical design method, the equivalent cantilever beam model is used to identify the mechanical properties of the metal rubber isolator, whose accuracy is verified by experiment. The static stiffness and dynamic stiffness are gained through a fitting method, considering different mass loadings. Different material parameters of a metal rubber isolator, such as relative densities, wire diameters, wire spiral pitch diameters, and mass loading from the power system, greatly influence the mechanical properties and stiffness characteristic. The vibration isolation performance of a metal rubber isolator applied in the AUG is evaluated by a nonlinear single degree of freedom dynamic model, which is solved by the harmonic balance method. The linear stiffness component of the metal rubber isolator is the main influence factor…

  18. 18
    top 2.1%

    Optical interference on the measurement of film-depth-dependent light absorption spectroscopy and a correction approach

    Guanyu Lu, Zichao Shen, Hong Wang, Laju Bu, Guanghao Lu

    23 citationsdoi:10.1063/5.0138336OpenAlex

    Show abstract

    Organic thin films usually feature vertical phase segregation, and film-depth-dependent light absorption spectroscopy is an emerging characterization method to study the vertical phase separation of active layer films in organic electronics field. However, the interference effects on thin films can lead to optical errors in their characterization results. In this work, the interference effects on fluctuations of peak intensity and peak position of film-depth-dependent light absorption spectroscopy are investigated. Subsequently, a numerical method based on inverse transfer matrix is proposed to obtain the optical constants of the active layer through the film-depth-dependent light absorption spectroscopy. The extinction coefficient error in the non-absorbing wavelength range caused by interference effect is reduced by ∼95% compared with the traditional film-depth-dependent light absorption spectroscopy measurement. Thus, the optical properties of the thin film and quantitative spectrographic analysis based on these optical constants largely avoid the effects of interference…

  19. 19
    top 2.2%

    X-ray self-emission imaging with spherically bent Bragg crystals on the Z-machine

    Eric C. Harding, G. K. Robertson, G. S. Dunham, M. R. Gómez, Jeffrey Fein and 7 more

    22 citationsdoi:10.1063/5.0143942OpenAlex

    Show abstract

    An x-ray imaging scheme using spherically bent crystals was implemented on the Z-machine to image x rays emitted by the hot, dense plasma generated by a Magnetized Liner Inertial Fusion (MagLIF) target. This diagnostic relies on a spherically bent crystal to capture x-ray emission over a narrow spectral range (<15 eV), which is established by a limiting aperture placed on the Rowland circle. The spherical crystal optic provides the necessary high-throughput and large field-of-view required to produce a bright image over the entire, one-cm length of the emitting column of a plasma. The average spatial resolution was measured and determined to be 18 µm for the highest resolution configuration. With this resolution, the radial size of the stagnation column can be accurately determined and radial structures, such as bifurcations in the column, are clearly resolved. The success of the spherical-crystal imager has motivated the implementation of a new, two-crystal configuration for identifying sources of spectral line emission using a differential imaging technique.

  20. 20
    top 2.3%

    A laser-based Ångstrom method for in-plane thermal characterization of isotropic and anisotropic materials using infrared imaging

    Aalok U. Gaitonde, Aaditya A. Candadai, Justin A. Weibel, Amy Marie Marconnet

    22 citationsdoi:10.1063/5.0149659OpenAlex

    Show abstract

    High heat fluxes generated in electronics and semiconductor packages require materials with high thermal conductivity to effectively diffuse the heat and avoid local hotspots. Engineered heat spreading materials typically exhibit anisotropic conduction behavior due to their composite construction. The design of thermal management solutions is often limited by the lack of fast and accurate characterization techniques for such anisotropic materials. A popular technique for measuring the thermal diffusivity of bulk materials is the Ångstrom method, where a thin strip or rod of material is heated periodically at one end, and the corresponding transient temperature profile is used to infer the thermal diffusivity. However, this method is generally limited to the characterization of one-dimensional samples and requires multiple measurements with multiple samples to characterize anisotropic materials. Here, we present a new measurement technique for characterizing the isotropic and anisotropic in-plane thermal properties of thin films and sheets as an extension of the one-dimensional…

  21. 21
    top 2.4%

    X-ray imaging methods for high-energy density physics applications

    Bernard J. Kozioziemski, B. Bachmann, Alexandre Do, Riccardo Tommasini

    22 citationsOpen accessdoi:10.1063/5.0130689OpenAlex

    Show abstract

    Large scale high-energy density science facilities continue to grow in scale and complexity worldwide. The increase in driver capabilities, including pulsed-power and lasers, continue to push the boundaries of temperature, pressure, and densities, opening up new physics regimes. X-ray imaging is one of the many diagnostic techniques that are used to probe states of matter in these extreme conditions. Improved fabrication and polishing methods have provided improved x-ray microscope performance, while improving detector and x-ray sources now enable pico-second imaging with few micron resolutions. This Review will cover x-ray imaging methods, primarily absorption imaging, and their improvements over the last few decades.

  22. 22
    top 2.5%

    Neutron imaging of inertial confinement fusion implosions

    David N. Fittinghoff, N. Birge, Verena Geppert-Kleinrath

    22 citationsOpen access (CC-BY)doi:10.1063/5.0124074OpenAlex

    Show abstract

    We review experimental neutron imaging of inertial confinement fusion sources, including the neutron imaging systems that have been used in our measurements at the National Ignition Facility. These systems allow measurements with 10 µm resolution for fusion deuterium-deuterium and deuterium-tritium neutron sources with mean radius up to 400 µm, including measurements of neutrons scattered to lower energy in the remaining cold fuel. These measurements are critical for understanding the fusion burn volume and the three-dimensional effects that can reduce the neutron yields.

  23. 23
    top 2.7%

    Frequency-domain probe beam deflection method for measurement of thermal conductivity of materials on micron length scale

    Jinchi Sun, Guangxin Lv, David G. Cahill

    22 citationsOpen accessdoi:10.1063/5.0126717OpenAlex

    Show abstract

    Time-domain thermoreflectance and frequency-domain thermoreflectance (FDTR) have been widely used for non-contact measurement of anisotropic thermal conductivity of materials with high spatial resolution. However, the requirement of a high thermoreflectance coefficient restricts the choice of metal coating and laser wavelength. The accuracy of the measurement is often limited by the high sensitivity to the radii of the laser beams. We describe an alternative frequency-domain pump-probe technique based on probe beam deflection. The beam deflection is primarily caused by thermoelastic deformation of the sample surface, with a magnitude determined by the thermal expansion coefficient of the bulk material to measure. We derive an analytical solution to the coupled elasticity and heat diffusion equations for periodic heating of a multilayer sample with anisotropic elastic constants, thermal conductivity, and thermal expansion coefficients. In most cases, a simplified model can reliably describe the frequency dependence of the beam deflection signal without knowledge of the elastic…

  24. 24
    top 2.8%

    Optical spectrum analyzers and typical applications in astronomy and remote sensing

    Chunsheng Yan, Yuwei Chen, Haima Yang, Eero Ahokas

    21 citationsOpen access (CC-BY)doi:10.1063/5.0138963OpenAlex

    Show abstract

    Scientists are increasingly relying on astronomical and remote sensing technologies to gain deeper insights into the Earth and the universe. In these fields, the optical spectrum analyzer (OSA) or spectrometer plays a pivotal role. This Review offers a comprehensive overview of the fundamental principles, key parameters, and applications of various branches of traditional OSAs, including prisms, gratings, interferometers, tunable filters, and reconstructive spectrometers. We specifically focus on their latest major applications in astronomy and remote sensing. Additionally, we present a mathematical model of the generalized reconstructive spectrometer and provide a summary of its principles pertaining to spectral mapping, reconstruction, and imaging. Despite its limited aperture and étendue, the reconstructive spectrometer holds great potential for future use in astronomy and remote sensing due to its compact size and exceptional ultrahigh spectral resolution.

  25. 25
    top 2.9%

    Hybrid CMOS detectors for high-speed X-ray imaging

    J. L. Porter, Quinn Looker, Liam D. Claus

    21 citationsOpen access (CC-BY)doi:10.1063/5.0138264OpenAlex

    Show abstract

    Hybrid CMOS (hCMOS) x-ray framing cameras are a new and powerful detector option for experiments in the fields of Inertial Confinement Fusion (ICF) and High Energy Density Physics (HEDP). These digital cameras capture multiple images along a single line-of-sight with a time resolution as short as 1.5 ns and with high quantum efficiency. To manage the high data rate, an image sequence is acquired in a short burst of time and subsequently read out on a much longer time scale. The technology is well suited for operating in high radiation environments, including fusion ignition experiments. Diagnostics using hCMOS cameras are now deployed in experiments on major laser and pulsed-power ICF facilities around the world. Continued advances in microelectronics technologies will enable faster and more capable detectors well into the future. This paper reviews this detector technology with a focus on application to ICF and HEDP experiments.

  26. 26
    top 3%

    Design and performance characterization of a new LISA-like (laser interferometer space antenna-like) gravitational reference sensor and torsion pendulum testbed

    Stephen Apple, Anthony Dávila Álvarez, Samantha Parry Kenyon, Andrew Chilton, Derek Klein and 12 more

    21 citationsdoi:10.1063/5.0135125OpenAlex

    Show abstract

    In this paper, we present the design and performance of the upgraded University of Florida torsion pendulum facility for testing inertial sensor technology related to space-based gravitational wave observatories and geodesy missions. In particular, much work has been conducted on inertial sensor technology related to the Laser Interferometer Space Antenna (LISA) space gravitational wave observatory mission. A significant upgrade to the facility was the incorporation of a newly designed and fabricated LISA-like gravitational reference sensor (GRS) based on the LISA Pathfinder GRS. Its LISA-like geometry has allowed us to make noise measurements that are more representative of those in LISA and has allowed for the characterization of the mechanisms of noise induced on a LISA GRS and their underlying physics. Noise performance results and experiments exploring the effect of temperature gradients across the sensor will also be discussed. The LISA-like sensor also includes unique UV light injection geometries for UV LED based charge management. Pulsed and DC charge management experiments…

  27. 27
    top 3.1%

    The high intensity diffractometer for residual stress analysis (HIDRA), a third generation residual stress mapping neutron diffractometer at the high flux isotope reactor

    Jeffrey R. Bunn, Chris M. Fancher, Edward Andrew Payzant, P Cornwell, W. B. Bailey and 1 more

    21 citationsOpen accessdoi:10.1063/5.0122250OpenAlex

    Show abstract

    This paper describes the hardware and software upgrades, operation, and performance of the high intensity diffractometer for residual stress analysis (HIDRA) instrument, a residual stress mapping neutron diffractometer located at the High Flux Isotope Reactor at Oak Ridge National Laboratory in Oak Ridge Tennessee, USA. Following a major upgrade in 2018, the new instrument has a single 3He multiwire 2D 30 × 30 cm2 position sensitive detector, yielding a field of view of 17° 2θ. The increase in the field of view (from 4° 2θ) from the previous model instrument has contributed to the tremendous improvement in the out of plane solid angle such that the 3D count rate could be obtained easily. Accordingly, the hardware, software, Data Acquisition System (DAS), and so on have also been updated. Finally, all these enhanced features of HIDRA have been ably demonstrated by conducting multi directional diffraction measurements in the quenched 750-T74 aluminum, and the evolved and improved strain/stress mappings are presented.

  28. 28
    top 3.2%

    Soft x-ray power diagnostics for fusion experiments at NIF, Omega, and Z facilities

    Michael S. Rubery, Gregory E. Kemp, Michael C. Jones, N. Pelepchan, Wayne C. Stolte and 1 more

    21 citationsdoi:10.1063/5.0131949OpenAlex

    Show abstract

    In this Review Article, we discuss a range of soft x-ray power diagnostics at inertial confinement fusion (ICF) and pulsed-power fusion facilities. This Review Article describes current hardware and analysis approaches and covers the following methods: x-ray diode arrays, bolometers, transmission grating spectrometers, and associated crystal spectrometers. These systems are fundamental for the diagnosis of ICF experiments, providing a wide range of critical parameters for the evaluation of fusion performance.

  29. 29
    top 3.3%

    Charged particle diagnostics for inertial confinement fusion and high-energy-density physics experiments

    Maria Gatu Johnson

    21 citationsOpen access (CC-BY)doi:10.1063/5.0127438OpenAlex

    Show abstract

    MeV-range ions generated in inertial confinement fusion (ICF) and high-energy-density physics experiments carry a wealth of information, including fusion reaction yield, rate, and spatial emission profile; implosion areal density; electron temperature and mix; and electric and magnetic fields. Here, the principles of how this information is obtained from data and the charged particle diagnostic suite currently available at the major US ICF facilities for making the measurements are reviewed. Time-integrating instruments using image plate, radiochromic film, and/or CR-39 detectors in different configurations for ion counting, spectroscopy, or emission profile measurements are described, along with time-resolving detectors using chemical vapor deposited diamonds coupled to oscilloscopes or scintillators coupled to streak cameras for measuring the timing of ion emission. A brief description of charged-particle radiography setups for probing subject plasma experiments is also given. The goal of the paper is to provide the reader with a broad overview of available capabilities, with…

  30. 30
    top 3.4%

    Scaling waveguide-integrated superconducting nanowire single-photon detector solutions to large numbers of independent optical channels

    Matthias Häußler, Robin Terhaar, Martin A. Wolff, Helge Gehring, Fabian Beutel and 9 more

    21 citationsOpen accessdoi:10.1063/5.0114903OpenAlex

    Show abstract

    Superconducting nanowire single-photon detectors are an enabling technology for modern quantum information science and are gaining attractiveness for the most demanding photon counting tasks in other fields. Embedding such detectors in photonic integrated circuits enables additional counting capabilities through nanophotonic functionalization. Here, we show how a scalable number of waveguide-integrated superconducting nanowire single-photon detectors can be interfaced with independent fiber optic channels on the same chip. Our plug-and-play detector package is hosted inside a compact and portable closed-cycle cryostat providing cryogenic signal amplification for up to 64 channels. We demonstrate state-of-the-art multi-channel photon counting performance with average system detection efficiency of (40.5 ± 9.4)% and dark count rate of (123 ± 34) Hz for 32 individually addressable detectors at minimal noise-equivalent power of (5.1 ± 1.2) · 10−18 W/Hz. Our detectors achieve timing jitter as low as 26 ps, which increases to (114 ± 17) ps for high-speed multi-channel operation using…

  31. 31
    top 3.6%

    A review of piezoelectric–electromagnetic hybrid energy harvesters for different applications

    Yuhang Han, Lipeng He, Lei Sun, Hongxin Wang, Zhonghua Zhang and 1 more

    20 citationsdoi:10.1063/5.0161822OpenAlex

    Show abstract

    Social progress is inseparable from the utilization of energy, signals of extreme consumption of fossil energy and energy crisis appear frequently around the world. Human beings are paying more and more attention to new technologies and the sustainable development of energy collection and conversion. The emergence of piezoelectric, electromagnetic, electrostatic, and triboelectric mechanisms provides a variety of effective methods for new environmental energy collection and conversion technologies. Among them, the piezoelectric-electromagnetic hybrid energy harvester (P-EHEH) has been widely studied due to its high output power, simple structure, and easy miniaturization. Continuous progress has been made in the research of P-EHEH through theoretical exploration, structural optimization, and performance improvement. This Review focuses on the review of P-EHEH at the application level. A detailed introduction summarizes the research status of P-EHEH applied to human body devices, monitoring sensors, and power supply devices, as well as the development status of back-end electronic…

  32. 32
    top 3.7%

    Characterizing the thermoelectric cooling performance across a broad temperature range

    Kun Liang, Hengyu Yang, Peng Zhao, Li Yin, Chenhao Lin and 5 more

    20 citationsdoi:10.1063/5.0165551OpenAlex

    Show abstract

    Thermoelectric cooling plays an essential role in precisely controlling the temperature of electronics. Characterizing the performance of thermoelectric coolers (TECs) is of great significance for the development of advanced solid-state cooling devices. However, the existing setup for characterizing the cooling performance of TECs has mainly been limited to the near room temperature range. Herein, we report the development of a new setup that is capable of characterizing thermoelectric cooling performance across a broad temperature range (80-350 K). With precise and steady control of the hot-side temperature, measurements of the coefficient of performance and maximum temperature difference at room temperature have been conducted on commercial devices. By comparing the results with the commercial datasheet, it shows that our setup can accurately evaluate the cooling performance of thermoelectric devices. In addition, we further extend the characterization to different hot-side temperatures, e.g., 173, 325, and 350 K, thus demonstrating the capability of our setup for evaluating the…

  33. 33
    top 3.8%

    Overview and first measurements of the MAST Upgrade bolometer diagnostic

    Jack J. Lovell, Matthew L. Reinke, A. R. Field, Bartosz A. Lomanowski, MAST Upgrade Team

    20 citationsOpen access (CC-BY)doi:10.1063/5.0128750OpenAlex

    Show abstract

    A suite of multi-channel resistive bolometers has been implemented to measure the total radiation from Mega Amp Spherical Tokamak Upgrade plasmas, with cameras covering the core plasma and lower divertor chamber. Data are digitized and processed using novel field-programmable gate array-based electronics, offering improved compactness and new operational capabilities. A synthetic diagnostic has been developed to explore the quality of 2D reconstructions available from the system and to quantify the uncertainty on quantities such as the total radiated power. Measurements in the first campaign have demonstrated correct functioning of the diagnostic while also highlighting issues with electrical noise and some failure mechanisms of the detectors, as well as significant neutral beam fast-particle losses.

  34. 34
    top 3.9%

    Mapping spectroscopic micro-ellipsometry with sub-5 microns lateral resolution and simultaneous broadband acquisition at multiple angles

    Ralfy Kenaz, Ronen Rapaport

    20 citationsOpen access (CC-BY)doi:10.1063/5.0123249OpenAlex

    Show abstract

    Spectroscopic ellipsometry is a widely used optical technique in both industry and research for determining the optical properties and thickness of thin films. The effective use of spectroscopic ellipsometry on micro-structures is inhibited by technical limitations on the lateral resolution and data acquisition rate. Here, we introduce a spectroscopic micro-ellipsometer (SME), capable of recording spectrally resolved ellipsometric data simultaneously at multiple angles of incidence in a single measurement of a few seconds, with a lateral resolution down to 2 μm in the visible spectral range. The SME can be easily integrated into generic optical microscopes by the addition of a few standard optical components. We demonstrate complex refractive index and thickness measurements by using the SME, which are in excellent agreement with a commercial spectroscopic ellipsometer. The high lateral resolution is displayed by complex refractive index and thickness maps over micron-scale areas. As an application for its accuracy and high lateral resolution, the SME can characterize the optical…

  35. 35
    top 4%

    Active stabilization of kilogauss magnetic fields to the ppm level for magnetoassociation on ultranarrow Feshbach resonances

    Mateusz Borkowski, Lukas Reichsöllner, Premjith Thekkeppatt, Vincent Barbé, Tijs van Roon and 2 more

    19 citationsOpen access (CC-BY)doi:10.1063/5.0143825OpenAlex

    Show abstract

    Feshbach association of ultracold molecules using narrow resonances requires exquisite control of the applied magnetic field. Here, we present a magnetic field control system to deliver magnetic fields of over 1000 G with ppm-level precision integrated into an ultracold-atom experimental setup. We combine a battery-powered, current-stabilized power supply with active feedback stabilization of the magnetic field using fluxgate magnetic field sensors. As a real-world test, we perform microwave spectroscopy of ultracold Rb atoms and demonstrate an upper limit on our magnetic field stability of 2.4(3) mG at 1050 G [2.3(3) ppm relative] as determined from the spectral feature.

  36. 36
    top 4.1%

    The fast camera (Fastcam) imaging diagnostic systems on the DIII-D tokamak

    C. Marini, J.A. Boedo, E.M. Hollmann, L. Chousal, J. Mills and 2 more

    19 citationsOpen accessdoi:10.1063/5.0149484OpenAlex

    Show abstract

    Two camera systems are installed on the DIII-D tokamak at the toroidal positions of 90° (90° system) and 225° (225° system), respectively. The cameras have two types of relay optics, namely, a coherent optical fiber bundle and a periscope system. The periscope system provides absolute intensity calibration stability while sacrificing resolution (10 lp/mm), while the fiber system provides high resolution (16 lp/mm) while sacrificing calibration stability. The periscope is available only for the 90° system. The optics of the 225° system were designed for view stability, repeatability, and easy maintenance. The cameras are located inside optimized neutron, x ray and magnetic shielding in order to reduce electronics damage, reboots, and magnetic and neutron interference, increasing the overall system reliability. An automated filter wheel, providing remote filter change, allows for remote wavelength selection. A software suite automates camera acquisition and data storage, allowing for remote operation and reduced operator involvement. System metadata is used to streamline the data…

  37. 37
    top 4.2%

    Performance of small- and wide-angle x-ray scattering beamline at Indus-2 synchrotron

    Avik Das, Jitendra Bahadur, Ashwani Kumar, Debasis Sen

    19 citationsdoi:10.1063/5.0121310OpenAlex

    Show abstract

    A Small- and Wide-Angle X-ray Scattering (SWAXS) beamline (BL-18) is installed and commissioned at a 1.5 T bending magnet port (5°) of Indus-2 synchrotron at RRCAT, Indore, India. The ∼40-m-long beamline has tunable x-ray energy in the range of 5-20 keV by using a double crystal monochromator. A 1.5-m-long toroidal mirror is used to focus the x-ray beam at the detector position. The beamline is equipped with a 6-m-long movable detector stage to access different wave-vector transfer ranges. At present, an online image plate area detector and a linear position-sensitive gas detector are installed for Small-Angle X-ray Scattering (SAXS) and Wide-Angle X-ray Scattering (WAXS) measurements, respectively. The beamline is operational in simultaneous SAXS/WAXS mode to probe the mesoscopic as well as molecular level structure over a wide range of wave-vector transfer. The specification of the beamline and its performance are reported here. A few recent experimental results, as obtained from BL-18, are also described in brief.

  38. 38
    top 4.3%

    Dual pulsed laser deposition system for the growth of complex materials and heterostructures

    P. Orgiani, Sandeep Kumar Chaluvadi, Shyni Punathum Chalil, Federico Mazzola, Anupam Jana and 11 more

    19 citationsOpen access (OTHER-OA)doi:10.1063/5.0138889OpenAlex

    Show abstract

    Here, we present an integrated ultra-high-vacuum (UHV) apparatus for the growth of complex materials and heterostructures. The specific growth technique is the Pulsed Laser Deposition (PLD) by means of a dual-laser source based on an excimer KrF ultraviolet and solid-state Nd:YAG infra-red lasers. By taking advantage of the two laser sources-both lasers can be independently used within the deposition chambers-a large number of different materials-ranging from oxides to metals, to selenides, and others-can be successfully grown in the form of thin films and heterostructures. All of the samples can be in situ transferred between the deposition chambers and the analysis chambers by using vessels and holders' manipulators. The apparatus also offers the possibility to transfer samples to remote instrumentation under UHV conditions by means of commercially available UHV-suitcases. The dual-PLD operates for in-house research as well as user facility in combination with the Advanced Photo-electric Effect beamline at the Elettra synchrotron radiation facility in Trieste and allows…

  39. 39
    top 4.5%

    Piezoelectric energy harvesting systems using mechanical tuning techniques

    Xuejin Liu, Lipeng He, Renwen Liu, Dianbin Hu, Limin Zhang and 1 more

    19 citationsdoi:10.1063/5.0120778OpenAlex

    Show abstract

    In this review, we review the recent research progress and results of piezoelectric energy harvesters applying mechanical tuning techniques in terms of literature background, methods of mechanical tuning, and practical applications. In the past few decades, piezoelectric energy harvesting techniques and mechanical tuning techniques have received increasing attention and made significant progress. Mechanical-tuning techniques are those that allow the resonant vibration energy harvesters the mechanical resonant frequency values to be adjusted to coincide with the excitation frequency. According to the different tuning methods, this review classifies mechanical-tuning techniques based on magnetic action, different piezoelectric materials, axial load, the variable center of gravity, various stresses, and self-tuning and summarizes the corresponding research results, comparing the differences between the same methods. In addition, the current application of the mechanical-tuning techniques is introduced, and the future development of mechanical tuning techniques is analyzed, facilitating…

  40. 40
    top 4.6%

    Electron pulse-dilation diagnostic instruments

    Clement A. Trosseille, S. R. Nagel, T. J. Hilsabeck

    19 citationsOpen accessdoi:10.1063/5.0128802OpenAlex

    Show abstract

    During the past decade, a number of diagnostic instruments have been developed that utilize electron pulse-dilation to achieve temporal resolution in the 5-30 ps range. These development efforts were motivated by the need for advanced diagnostics for high-energy density physics experiments around the world. The new instruments include single- and multi-frame gated imagers and non-imaging detectors that record continuous data streams. Electron pulse-dilation provides high-speed detection capability by converting incoming signals into a free electron cloud and manipulating the electron signal with electric and magnetic fields. Here, we discuss design details and applications of these instruments along with issues and challenges associated with employing the electron pulse-dilation technique. Additionally, methods to characterize instrument performance and improve tolerance to gamma and neutron background radiation are discussed.

  41. 41
    top 4.7%

    Development of a pulse modulated sub-radio frequency power supply for atmospheric pressure plasma devices

    Aishik Basu Mallick, G. Veda Prakash, Satyananda Kar, R. Narayanan

    18 citationsdoi:10.1063/5.0173873OpenAlex

    Show abstract

    The effect of pulse-modulated sub-RF range (100 kHz-1 MHz) excitation on atmospheric pressure argon plasma jet characteristics is studied. For this, a suitable power supply is developed, offering a sub-µs rise time with control of different parameters, such as voltage amplitude, pulse modulation frequency in the range of 1-30 kHz, and an oscillation frequency of ∼520 kHz, which can affect the plasma behavior. Plasma characteristics, such as reactive species generation, ionic composition, plasma plume length, and gas temperature, are evaluated qualitatively and quantitatively by employing diagnostics such as optical emission spectroscopy, molecular beam mass spectrometry, and optical imaging. Experimental observations indicate that the gas temperature of the plasma jet and plume length increase with the applied voltage for all pulse modulation frequencies, with a maximum value of ∼(325 ± 2 K) and a maximum length of ∼(23 ± 3 mm), respectively, at 30 kHz and 9 kVpp. The emission intensities of OH• and O• lines show an incremental behavior with the applied voltage across all pulse…

  42. 42
    top 4.8%

    Development of a cryogen-free sub-3 K low-temperature scanning probe microscope by remote liquefaction scheme

    Ruisong Ma, Hao Li, Chenshuai Shi, Fan Wang, Le Lei and 8 more

    18 citationsdoi:10.1063/5.0165089OpenAlex

    Show abstract

    We developed a new scheme for cryogen-free cooling down to sub-3 K temperature range and ultra-low vibration level. An ultra-high-vacuum cryogen-free scanning probe microscope (SPM) system was built based on the new scheme. Instead of mounting a below-decoupled cryocooler directly onto the system, the new design was realized by integrating a Gifford-McMahon cryocooler into a separate liquefying chamber, providing two-stage heat exchangers in a remote way. About 10 L of helium gas inside the gas handling system was cooled, liquefied in the liquefying chamber, and then transferred to a continuous-flow cryostat on the SPM chamber through an ∼2 m flexible helium transfer line. The exhausted helium gas from the continuous-flow cryostat was then returned to the liquefying chamber for reliquefaction. A base temperature of ∼2.84 K at the scanner sample stage and a temperature fluctuation of almost within ±0.1 mK at 4 K were achieved. The cooling curves, tunneling current noise, variable-temperature test, scanning tunneling microscopy and non-contact atomic force microscopy imaging, and…

  43. 43
    top 4.9%

    Spectroscopy of helium-tagged molecular ions—Development of a novel experimental setup

    Stefan Bergmeister, Lisa Ganner, Johannes Locher, Fábio Zappa, P. Scheier and 1 more

    18 citationsOpen access (CC-BY)doi:10.1063/5.0144239OpenAlex

    Show abstract

    In this contribution, we present an efficient and alternative method to the commonly used RF-multipole trap technique to produce He-tagged molecular ions at cryogenic temperatures, which are perfectly suitable for messenger spectroscopy. The seeding of dopant ions in multiply charged helium nanodroplets, in combination with a gentle extraction of the latter from the helium matrix, enables the efficient production of He-tagged ion species. With a quadrupole mass filter, a specific ion of interest is selected, merged with a laser beam, and the photoproducts are measured in a time-of-flight mass-spectrometer. The detection of the photofragment signal from a basically zero background is much more sensitive than the depletion of the same amount of signal from precursor ions, delivering high quality spectra at reduced data acquisition times. Proof-of-principle measurements of bare and He-tagged Ar-cluster ions, as well as of He-tagged C60 ions, are presented.

  44. 44
    top 5%

    A review of recent studies on valve-less piezoelectric pumps

    Wei Li, Dabing Li, Lipeng He, Yage Wang, De Wang and 1 more

    18 citationsdoi:10.1063/5.0135700OpenAlex

    Show abstract

    Due to the advantages of small size, low power consumption and price, no wear, and reliable performances of valve-less piezoelectric pumps, which academics have studied and gained excellent consequences for, valve-less pumps are applied in the following fields: fuel supply, chemical analysis, biological fields, drug injection, lubrication, irrigation of experiment fields, etc. In addition, they will broaden the application scope in micro-drive fields and cooling systems in the future. During this work, first, the valve structures and output capabilities of the passive valve and active valve piezoelectric pumps are discussed. Second, the various forms of symmetrical structure, asymmetrical structure, and drive variant structure valve-less pumps are introduced, the working processes are illustrated, and the advantages and disadvantages of pump characteristics with the flow rate and pressure are analyzed under different driving conditions. In this process, some optimization methods with theoretical and simulation analysis are explained. Third, the applications of valve-less pumps are…

  45. 45
    top 5.1%

    A versatile biaxial stretching device for in situ synchrotron radiation small- and wide-angle x-ray scattering measurements of polymer films

    Jianhe Zhu, Shenghui Liu, Yimin Lu, Hong Cheng, Xueqing Han and 5 more

    18 citationsdoi:10.1063/5.0130284OpenAlex

    Show abstract

    A biaxial stretching device is designed and developed for the real-time structural measurements of polymer films. This device adopts a vertical layout to perform real-time x-ray scattering measurements. It has a maximum stretching ratio of 8 × 8 in two perpendicular directions. Its maximum experimental temperature and stretching rate are 250 °C and 100 mm/s, respectively. The control accuracies of the experimental temperature and stretching rate are ±1 °C and 0.01 mm, respectively. All the parameters related to film biaxial processing, such as stretching speed, stretching ratio, and temperature, can be independently set. The device feasibility is demonstrated via a real-time experiment in a synchrotron radiation beamline. Wide-angle x-ray diffraction, small-angle x-ray scattering, and stress-strain data can be simultaneously obtained during various stretching modes. The proposed device fills the gap between the synchrotron radiation x-ray scattering technique and the biaxial stretching processing of polymer films. This device will play an important role in improving the…

  46. 46
    top 5.3%

    Design of a multi-direction piezoelectric and electromagnetic hybrid energy harvester used for ocean wave energy harvesting

    Liang Chen, Chong Li, Jiwen Fang

    17 citationsdoi:10.1063/5.0160131OpenAlex

    Show abstract

    Ocean waves contain a great deal of energy, and the collection and utilization of wave energy is of great significance for sustainable development. In this paper, a multi-direction piezoelectric and electromagnetic hybrid energy harvester (PEHEH) based on magnetic coupling is proposed that can collect low frequency vibration energy from multiple directions. The proposed PEHEH combines piezoelectricity and electromagnetism through magnetic coupling to collect energy in the same excitation. The mechanical model of the PEHEH is established, and finite element simulation software COMSOL and computational fluid dynamics are used to analyze and verify the feasibility and practicability of the PEHEH structure. An experimental platform is built to test the output performance of the PEHEH. The results show that the maximum energy generated by PEHEH is 19.4 mW when the magnetic distance is 16 mm and the excitation frequency is 9 Hz. The hybrid energy harvester can light 56 light emitting diodes, which verified the feasibility of practical application. Therefore, the proposed hybrid energy…

  47. 47
    top 5.4%

    A laboratory-based multifunctional near ambient pressure X-ray photoelectron spectroscopy system for electrochemical, catalytic, and cryogenic studies

    Leander Haug, Christoph Grießer, Christoph Walter Thurner, Daniel Winkler, Toni Moser and 12 more

    17 citationsOpen access (CC-BY)doi:10.1063/5.0151755OpenAlex

    Show abstract

    A versatile multifunctional laboratory-based near ambient pressure x-ray photoelectron spectroscopy (XPS) instrument is presented. The entire device is highly customized regarding geometry, exchangeable manipulators and sample stages for liquid- and solid-state electrochemistry, cryochemistry, and heterogeneous catalysis. It therefore delivers novel and unique access to a variety of experimental approaches toward a broad choice of functional materials and their specific surface processes. The high-temperature (electro)catalysis manipulator is designed for probing solid state/gas phase interactions for heterogeneous catalysts including solid electrolyzer/fuel cell electrocatalysts at pressures up to 15 mbar and temperatures from room temperature to 1000 °C. The liquid electrochemistry manipulator is specifically designed for in situ spectroscopic investigations of polarized solid/liquid interfaces using aqueous electrolytes and the third one for experiments for ice and ice-like materials at cryogenic temperatures to approximately -190 °C. The flexible and modular combination of these…

  48. 48
    top 5.5%

    Calibration and thermal test results of prototype bolometer sensors for ITER fusion reactor

    Sina Jahanbakhsh, Jack Hare, Hans Meister, L. C. Ingesson, M. Majewski and 4 more

    17 citationsOpen access (CC-BY)doi:10.1063/5.0134449OpenAlex

    Show abstract

    For over 10 years, several bolometer sensors with different properties have been tested in the IBOVAC facility. The aim has been to develop a bolometer sensor that can be operated in ITER and can withstand harsh operating conditions. For this purpose, important physical properties of the sensors, i.e., cooling time constant τ, normalized heat capacity κ, and normalized sensitivity sn, have been characterized in a vacuum condition and at various temperatures up to 300 °C. The calibration is achieved by ohmic heating of the sensor absorbers by applying a DC voltage and recording exponential current fall during heating. Recently, a Python program was developed to analyze the data and extract the above mentioned parameters including the uncertainties from recorded currents. In the present series of experiments, the latest prototype sensors developed for ITER are tested and evaluated. These include three different sensor types: two with Au absorbers on ZrO2 membranes (self-supporting substrate sensors) and one with Au absorbers on Si3N4 membranes supported by a Si frame (supported…

  49. 49
    top 5.6%

    Radiation, optical, power flow, and electrical diagnostics at the Z facility: Layout and techniques utilized to operate in the harsh environment

    Timothy Webb, David E. Bliss, Gordon A. Chandler, Daniel H. Dolan, G. S. Dunham and 14 more

    17 citationsdoi:10.1063/5.0123448OpenAlex

    Show abstract

    The Z machine is a current driver producing up to 30 MA in 100 ns that utilizes a wide range of diagnostics to assess accelerator performance and target behavior conduct experiments that use the Z target as a source of radiation or high pressures. We review the existing suite of diagnostic systems, including their locations and primary configurations. The diagnostics are grouped in the following categories: pulsed power diagnostics, x-ray power and energy, x-ray spectroscopy, x-ray imaging (including backlighting, power flow, and velocimetry), and nuclear detectors (including neutron activation). We will also briefly summarize the primary imaging detectors we use at Z: image plates, x-ray and visible film, microchannel plates, and the ultrafast x-ray imager. The Z shot produces a harsh environment that interferes with diagnostic operation and data retrieval. We term these detrimental processes "threats" of which only partial quantifications and precise sources are known. We summarize the threats and describe techniques utilized in many of the systems to reduce noise and backgrounds.

  50. 50
    top 5.7%

    An ultra-high vacuum system for fabricating clean two-dimensional material devices

    Shuaifei Guo, Mingyan Luo, Gang Shi, Ning Tian, Zhe Huang and 13 more

    17 citationsdoi:10.1063/5.0110875OpenAlex

    Show abstract

    High mobility electron gases confined at material interfaces have been a venue for major discoveries in condensed matter physics. Ultra-high vacuum (UHV) technologies played a key role in creating such high-quality interfaces. The advent of two-dimensional (2D) materials brought new opportunities to explore exotic physics in flat lands. UHV technologies may once again revolutionize research in low dimensions by facilitating the construction of ultra-clean interfaces with a wide variety of 2D materials. Here, we describe the design and operation of a UHV 2D material device fabrication system, in which the entire fabrication process is performed under pressure lower than 5 × 10−10 mbar. Specifically, the UHV system enables the exfoliation of atomically clean 2D materials. Subsequent in situ assembly of van der Waals heterostructures produces high-quality interfaces that are free of contamination. We demonstrate functionalities of this system through exemplary fabrication of various 2D materials and their heterostructures.

How to read this list

The cohort is every article, review and book chapter OpenAlex attributes to Review of Scientific Instruments with publication year 2023, excluding retracted works and paratext such as editorials and errata. The top 50 by citation count are listed; the percentile is the rank divided by the cohort size. 50 of the 50 entries have an abstract in OpenAlex. Counts were read on 29 October 2026 and will not be updated on this page, so a quoted rank stays verifiable. Full rules on the methodology page.

Other journals, same idea

Work with these 25 papers in Kahubi

  • The papers land in your library with their DOIs
  • Ask anything across all of them, with citations
  • Draft a literature review from the same sources

Free plan, no card. Your files stay private unless you share them.

Reading several of these?

Kahubi reads papers with you, keeps every citation traceable and drafts with sources you can check. Free plan, no card.