Most-cited articles · 2021
The 50 most-cited articles in Review of Scientific Instruments, 2021
Ranked by OpenAlex citation count on 29 October 2026, out of 1,115 eligible articles Review of Scientific Instruments published in 2021. Ranks are frozen; this page will not change. Number one, with 154 citations: Entangled photon-pair sources based on three-wave mixing in bulk crystals.
- Cohort
- 1,115 articles
- Listed
- Top 50 (4.5%)
- Open access
- 32 of 50
- Snapshot
- 2026-10-29
The 2021 list is led by entangled photon-pair sources based on three-wave mixing in bulk crystals, with 154 citations, followed by faster high-speed atomic force microscopy for imaging of biomolecular processes at 73 citations and the Axion Dark Matter Experiment detailed design and operations at 59 citations. Quantum photonics, scanning probe microscopy for biological samples, and dark matter detection therefore occupy the top positions, with instrumentation for energy harvesting, spectroscopy, and imaging also appearing among the most-cited entries.
For readers, the ranking offers a neutral snapshot of which 2021 Review of Scientific Instruments papers attracted the most citation attention from a pool of 1115 eligible articles. The titles and abstracts indicate coverage of quantum sensing, plasma diagnostics, cryogenic apparatus, and microfluidic and imaging instrumentation, so the list can serve as a starting point for locating frequently referenced work in these areas.
Introduction written from the titles and abstracts on this list. Every figure below is the source.
Ask about these papers
Grounded in this list only, with sources.
- 1top 0.1%
Entangled photon-pair sources based on three-wave mixing in bulk crystals
Ali Anwar, Chithrabhanu Perumangatt, Fabian Steinlechner, Thomas Jennewein, Alexander Ling
154 citationsOpen accessdoi:10.1063/5.0023103OpenAlex
Show abstractHide abstract
Entangled photon pairs are a critical resource in quantum communication protocols ranging from quantum key distribution to teleportation. The current workhorse technique for producing photon pairs is via spontaneous parametric down conversion (SPDC) in bulk nonlinear crystals. The increased prominence of quantum networks has led to a growing interest in deployable high performance entangled photon-pair sources. This manuscript provides a review of the state-of-the-art bulk-optics-based SPDC sources with continuous wave pump and discusses some of the main considerations when building for deployment.
- 2top 0.2%
Faster high-speed atomic force microscopy for imaging of biomolecular processes
Shingo Fukuda, Toshio Ando
73 citationsOpen access (CC-BY)doi:10.1063/5.0032948OpenAlex
Show abstractHide abstract
High-speed atomic force microscopy (HS-AFM) has enabled observing protein molecules during their functional activity at rates of 1-12.5 frames per second (fps), depending on the imaging conditions, sample height, and fragility. To meet the increasing demand for the great expansion of observable dynamic molecular processes, faster HS-AFM with less disturbance is imperatively needed. However, even a 50% improvement in the speed performance imposes tremendous challenges, as the optimization of major rate-limiting components for their fast response is nearly matured. This paper proposes an alternative method that can lower the feedback control error and thereby enhance the imaging rate. This method can be implemented in any HS-AFM system by minor modifications of the software and hardware. The resulting faster and less-disturbing imaging capabilities are demonstrated by the imaging of relatively fragile actin filaments and microtubules near the video rate, and of actin polymerization that occurs through weak intermolecular interactions, at ∼8 fps.
- 3top 0.3%
Axion Dark Matter Experiment: Detailed design and operations
Rakshya Khatiwada, D. Bowring, Aaron S. Chou, A. Sonnenschein, William C. Wester and 25 more
59 citationsOpen accessdoi:10.1063/5.0037857OpenAlex
Show abstractHide abstract
Axion dark matter experiment ultra-low noise haloscope technology has enabled the successful completion of two science runs (1A and 1B) that looked for dark matter axions in the 2.66-3.1 μeV mass range with Dine-Fischler-Srednicki-Zhitnisky sensitivity [Du et al., Phys. Rev. Lett. 120, 151301 (2018) and Braine et al., Phys. Rev. Lett. 124, 101303 (2020)]. Therefore, it is the most sensitive axion search experiment to date in this mass range. We discuss the technological advances made in the last several years to achieve this sensitivity, which includes the implementation of components, such as the state-of-the-art quantum-noise-limited amplifiers and a dilution refrigerator. Furthermore, we demonstrate the use of a frequency tunable microstrip superconducting quantum interference device amplifier in run 1A, and a Josephson parametric amplifier in run 1B, along with novel analysis tools that characterize the system noise temperature.
- 4top 0.4%
Rotational energy harvesting systems using piezoelectric materials: A review
Zhe Wang, Lipeng He, Xiangfeng Gu, Yang Shuo, Shicheng Wang and 2 more
52 citationsdoi:10.1063/5.0039730OpenAlex
Show abstractHide abstract
In the past few decades, rotary energy harvesting has received more and more attention and made great progress. The energy harvesting device aims to collect environmental energy around electronic equipment and convert it into usable electrical energy, developing self-powered equipment that does not require replaceable power supplies. This paper provides a holistic review of energy harvesting techniques from rotary motion using piezoelectric materials. It introduces the basic principles of piezoelectric energy harvesting, the vibrational modes of piezoelectric elements, and the materials of piezoelectric elements. There are four types of rotational energy harvesting technologies: inertial excitation, contact execution, magnetic coupling, and hybrid systems. An overview of each technology is made, and then, a detailed analysis is carried out. Different types of rotating energy harvesting technologies are compared, and the advantages and disadvantages of each technology are analyzed. Finally, this paper discusses the future direction and goals of improving energy harvesting technology.…
- 5top 0.5%
Deep learning-based statistical noise reduction for multidimensional spectral data
Younsik Kim, Dongjin Oh, Soonsang Huh, Dongjoon Song, Sunbeom Jeong and 12 more
48 citationsOpen accessdoi:10.1063/5.0054920OpenAlex
Show abstractHide abstract
In spectroscopic experiments, data acquisition in multi-dimensional phase space may require long acquisition time, owing to the large phase space volume to be covered. In such a case, the limited time available for data acquisition can be a serious constraint for experiments in which multidimensional spectral data are acquired. Here, taking angle-resolved photoemission spectroscopy (ARPES) as an example, we demonstrate a denoising method that utilizes deep learning as an intelligent way to overcome the constraint. With readily available ARPES data and random generation of training datasets, we successfully trained the denoising neural network without overfitting. The denoising neural network can remove the noise in the data while preserving its intrinsic information. We show that the denoising neural network allows us to perform a similar level of second-derivative and line shape analysis on data taken with two orders of magnitude less acquisition time. The importance of our method lies in its applicability to any multidimensional spectral data that are susceptible to statistical…
- 6top 0.6%
High-energy x-ray nanotomography introducing an apodization Fresnel zone plate objective lens
Akihisa Takeuchi, Kentaro Uesugi, Masayuki Uesugi, Hiroyuki Toda, Kyosuke Hirayama and 3 more
47 citationsOpen accessdoi:10.1063/5.0020293OpenAlex
Show abstractHide abstract
In this study, high-energy x-ray nanotomography (nano-computed tomography, nano-CT) based on full-field x-ray microscopy was developed. Fine two-dimensional and three-dimensional (3D) structures with linewidths of 75 nm-100 nm were successfully resolved in the x-ray energy range of 15 keV-37.7 keV. The effective field of view was ∼60 µm, and the typical measurement time for one tomographic scan was 30 min-60 min. The optical system was established at the 250-m-long beamline 20XU of SPring-8 to realize greater than 100× magnification images. An apodization Fresnel zone plate (A-FZP), specifically developed for high-energy x-ray imaging, was used as the objective lens. The design of the A-FZP for high-energy imaging is discussed, and its diffraction efficiency distribution is evaluated. The spatial resolutions of this system at energies of 15 keV, 20 keV, 30 keV, and 37.7 keV were examined using a test object, and the measured values are shown to be in good agreement with theoretical values. High-energy x-ray nano-CT in combination with x-ray micro-CT is applied for 3D multiscale…
- 7top 0.7%
Single-pixel imaging: An overview of different methods to be used for 3D space reconstruction in harsh environments
Carlos Alexander Osorio Quero, Daniel Durini, Jose Rangel‐Magdaleno, José Martínez-Carranza
40 citationsdoi:10.1063/5.0050358OpenAlex
Show abstractHide abstract
Different imaging solutions have been proposed over the last few decades, aimed at three-dimensional (3D) space reconstruction and obstacle detection, either based on stereo-vision principles using active pixel sensors operating in the visible part of the spectra or based on active Near Infra-Red (NIR) illumination applying the time-of-flight principle, to mention just a few. If extremely low quantum efficiencies for NIR active illumination yielded by silicon-based detector solutions are considered together with the huge photon noise levels produced by the background illumination accompanied by Rayleigh scattering effects taking place in outdoor applications, the operating limitations of these systems under harsh weather conditions, especially if relatively low-power active illumination is used, are evident. If longer wavelengths for active illumination are applied to overcome these issues, indium gallium arsenide (InGaAs)-based photodetectors become the technology of choice, and for low-cost solutions, using a single InGaAs photodetector or an InGaAs line-sensor becomes a promising…
- 8top 0.8%
High-power near-concentric Fabry–Perot cavity for phase contrast electron microscopy
Carter Turnbaugh, Jeremy J. Axelrod, Sara L. Campbell, Jeske Y. Dioquino, Petar N. Petrov and 6 more
40 citationsOpen access (CC-BY)doi:10.1063/5.0045496OpenAlex
Show abstractHide abstract
Transmission electron microscopy (TEM) of vitrified biological macromolecules (cryo-EM) is limited by the weak phase contrast signal that is available from such samples. Using a phase plate would thus substantially improve the signal-to-noise ratio. We have previously demonstrated the use of a high-power Fabry–Perot cavity as a phase plate for TEM. We now report improvements to our laser cavity that allow us to achieve record continuous wave intensities of over 450 GW/cm2, sufficient to produce the optimal 90° phase shift for 300 keV electrons. In addition, we have performed the first cryo-EM reconstruction using a laser phase plate, demonstrating that the stability of this laser phase plate is sufficient for use during standard cryo-EM data collection.
- 9top 0.9%
A robust fiber-based quantum thermometer coupled with nitrogen-vacancy centers
Shao-Chun Zhang, Yang Dong, Bo Du, Hao-Bin Lin, Li Shen and 5 more
40 citationsOpen accessdoi:10.1063/5.0044824OpenAlex
Show abstractHide abstract
The nitrogen-vacancy center in diamond has been broadly applied in quantum sensing since it is sensitive to different physical quantities. Meanwhile, it is difficult to isolate disturbances from unwanted physical quantities in practical applications. Here, we present a fiber-based quantum thermometer by tracking the sharp-dip in the zero-field optically detected magnetic resonance spectrum in a high-density nitrogen-vacancy ensemble. Such a scheme can not only significantly isolate the magnetic field and microwave power drift but also improve the temperature sensitivity. Thanks to its simplicity and compatibility in implementation and robustness, this quantum thermometer is then applied to the surface temperature imaging of an electronic chip with a sensitivity of 18mK/Hz. It thus paves the way to high sensitive temperature measurements in ambiguous environments.
- 10top 0.9%
Measuring the electron temperature and identifying plasma detachment using machine learning and spectroscopy
C. M. Samuell, A. G. Mclean, C. A. Johnson, F. Glass, A. E. Jaervinen
40 citationsOpen accessdoi:10.1063/5.0034552OpenAlex
Show abstractHide abstract
A machine learning approach has been implemented to measure the electron temperature directly from the emission spectra of a tokamak plasma. This approach utilized a neural network (NN) trained on a dataset of 1865 time slices from operation of the DIII-D tokamak using extreme ultraviolet/vacuum ultraviolet emission spectroscopy matched with high-accuracy divertor Thomson scattering measurements of the electron temperature, Te. This NN is shown to be particularly good at predicting Te at low temperatures (Te < 10 eV) where the NN demonstrated a mean average error of less than 1 eV. Trained to detect plasma detachment in the tokamak divertor, a NN classifier was able to correctly identify detached states (Te < 5 eV) with a 99% accuracy (an F1 score of 0.96) at an acquisition rate 10× faster than the Thomson scattering measurement. The performance of the model is understood by examining a set of 4800 theoretical spectra generated using collisional radiative modeling that was also used to predict the performance of a low-cost spectrometer viewing nitrogen emission in the visible…
- 11top 1%
Characterizing cryogenic amplifiers with a matched temperature-variable noise source
Slawomir Simbierowicz, Visa Vesterinen, Joshua Milem, Aleksi Lintunen, Mika Oksanen and 5 more
40 citationsOpen access (CC-BY)doi:10.1063/5.0028951OpenAlex
Show abstractHide abstract
We present a cryogenic microwave noise source with a characteristic impedance of 50 Ω, which can be installed in a coaxial line of a cryostat. The bath temperature of the noise source is continuously variable between 0.1 K and 5 K without causing significant back-action heating on the sample space. As a proof-of-concept experiment, we perform Y-factor measurements of an amplifier cascade that includes a traveling wave parametric amplifier and a commercial high electron mobility transistor amplifier. We observe system noise temperatures as low as 680−200+20 mK at 5.7 GHz corresponding to 1.5−0.7+0.1 excess photons. The system we present has immediate applications in the validation of solid-state qubit readout lines.
- 12top 1.1%
Imaging pyrometry for most color cameras using a triple pass filter
Kevin L. McNesby, Steven W. Dean, Richard A. Benjamin, Jesse Grant, James Anderson and 1 more
39 citationsOpen access (CC-BY)doi:10.1063/5.0037230OpenAlex
Show abstractHide abstract
A simple combination of the Planck blackbody emission law, optical filters, and digital image processing is demonstrated to enable most commercial color cameras (still and video) to be used as an imaging pyrometer for flames and explosions. The hardware and data processing described take advantage of the color filter array (CFA) that is deposited on the surface of the light sensor array present in most digital color cameras. In this work, a triple-pass optical filter incorporated into the camera lens allows light in three 10-nm wide bandpass regions to reach the CFA/light sensor array. These bandpass regions are centered over the maxima in the blue, green, and red transmission regions of the CFA, minimizing the spectral overlap of these regions normally present. A computer algorithm is used to retrieve the blue, green, and red image matrices from camera memory and correct for remaining spectral overlap. A second algorithm calibrates the corrected intensities to a gray body emitter of known temperature, producing a color intensity correction factor for the camera/filter system. The…
- 13top 1.2%
Thermal conductivity measurements of sub-surface buried substrates by steady-state thermoreflectance
Md Shafkat Bin Hoque, Yee Rui Koh, Kiumars Aryana, Eric R. Hoglund, Jeffrey L. Braun and 8 more
38 citationsOpen access (CC-BY)doi:10.1063/5.0049531OpenAlex
Show abstractHide abstract
Measuring the thermal conductivity of sub-surface buried substrates is of significant practical interests. However, this remains challenging with traditional pump-probe spectroscopies due to their limited thermal penetration depths. Here, we experimentally and numerically investigate the TPD of the recently developed optical pump-probe technique steady-state thermoreflectance (SSTR) and explore its capability for measuring the thermal properties of buried substrates. The conventional definition of the TPD (i.e., the depth at which temperature drops to 1/e value of the maximum surface temperature) does not truly represent the upper limit of how far beneath the surface SSTR can probe. For estimating the uncertainty of SSTR measurements of a buried substrate a priori, sensitivity calculations provide the best means. Thus, detailed sensitivity calculations are provided to guide future measurements. Due to the steady-state nature of SSTR, it can measure the thermal conductivity of buried substrates that are traditionally challenging by transient pump-probe techniques, exemplified by…
- 14top 1.3%
The five line-of-sight neutron time-of-flight (nToF) suite on the National Ignition Facility (NIF)
A. S. Moore, Edward P. Hartouni, D. J. Schlossberg, S. Kerr, Mark J. Eckart and 8 more
38 citationsdoi:10.1063/5.0040730OpenAlex
Show abstractHide abstract
Measurement of the neutron spectrum from inertial confinement fusion implosions is one of the primary diagnostics of implosion performance. Analysis of the spectrum gives access to quantities such as neutron yield, hot-spot velocity, apparent ion temperature, and compressed fuel ρr through measurement of the down-scatter ratio. On the National Ignition Facility, the neutron time-of-flight suite has been upgraded to include five independent, collimated lines of sight, each comprising a high dynamic range bibenzyl/diphenylacetylene-stilbene scintillator [R. Hatarik et al., Plasma Fusion Res. 9, 4404104 (2014)] and high-speed fused silica Cherenkov detectors [A. S. Moore et al., Rev. Sci. Instrum. 89, 10I120 (2018)].
- 15top 1.4%
A 1D Lyman-alpha profile camera for plasma edge neutral studies on the DIII-D tokamak
A. Rosenthal, J. W. Hughes, A. Bortolon, Florian M. Laggner, T. M. Wilks and 6 more
37 citationsOpen access (CC-BY)doi:10.1063/5.0024115OpenAlex
Show abstractHide abstract
A one dimensional, absolutely calibrated pinhole camera system was installed on the DIII-D tokamak to measure edge Lyman-alpha (Ly-α) emission from hydrogen isotopes, which can be used to infer neutral density and ionization rate profiles. The system is composed of two cameras, each providing a toroidal fan of 20 lines of sight, viewing the plasma edge on the inboard and outboard side of DIII-D. The cameras' views lie in a horizontal plane 77 cm below the midplane. At its tangency radius, each channel provides a radial resolution of ∼2 cm full width at half maximum (FWHM) with a total coverage of 22 cm. Each camera consists of a rectangular pinhole, Ly-α reflective mirror, narrow-band Ly-α transmission filter, and a 20 channel AXUV photodetector. The combined mirror and transmission filter have a FWHM of 5 nm, centered near the Ly-α wavelength of 121.6 nm and is capable of rejecting significant, parasitic carbon-III (C-III) emission from intrinsic plasma impurities. To provide a high spatial resolution measurement in a compact footprint, the camera utilizes advanced engineering and…
- 16top 1.5%
Review of ultrasonic measurement methods for two-phase flow
Jinhui Fan, Fei Wang
36 citationsdoi:10.1063/5.0049046OpenAlex
Show abstractHide abstract
Two-phase flow is commonly used in many aspects of industrial production, such as the mixed transport of oil and gas in petroleum exploitation and the feeding of coal powder or coal water slurry to coal-fired boilers. In these situations, it is necessary to measure the two-phase flow in real time and then adjust various parameters in order to achieve high efficiency, energy-saving, and safe production. The ultrasonic method is widely used to measure two-phase flow because of its various measurement approaches, wide range of measurable parameters, insignificant effect on the flow field, and its capacity for continuous online measurement. In this Review, the principles, characteristics, application scope, and research examples of different ultrasonic methods used in two-phase flow measurement are summarized, their advantages and disadvantages are compared, and the future development trends are forecast, which will play a positive role in the development of two-phase flow measurement.
- 17top 1.6%
Horizon: Microfluidic platform for the production of therapeutic microbubbles and nanobubbles
Radwa H. Abou‐Saleh, Fern J. Armistead, Damien V. B. Batchelor, Benjamin R. G. Johnson, Sally A. Peyman and 1 more
36 citationsOpen access (CC-BY)doi:10.1063/5.0040213OpenAlex
Show abstractHide abstract
Microbubbles (MBs) have a multitude of applications including as contrast agents in ultrasound imaging and as therapeutic drug delivery vehicles, with further scope for combining their diagnostic and therapeutic properties (known as theranostics). MBs used clinically are commonly made by mechanical agitation or sonication methods, which offer little control over population size and dispersity. Furthermore, clinically used MBs are yet to be used therapeutically and further research is needed to develop these theranostic agents. In this paper, we present our MB production instrument "Horizon," which is a robust, portable, and user-friendly instrument, integrating the key components for producing MBs using microfluidic flow-focusing devices. In addition, we present the system design and specifications of Horizon and the optimized protocols that have so far been used to produce MBs with specific properties. These include MBs with tailored size and low dispersity (monodisperse); MBs with a diameter of ∼2 μm, which are more disperse but also produced in higher concentration; nanobubbles…
- 18top 1.7%
A line-scanning chromatic confocal sensor for three-dimensional profile measurement on highly reflective materials
Hao Hu, Shuang Mei, Liming Fan, Huigang Wang
35 citationsdoi:10.1063/5.0043922OpenAlex
Show abstractHide abstract
We developed a practical Line-Scanning Chromatic Confocal Sensor (LSCCS) that can generate three-dimensional (3D) points with up to 32 000/s with a high-precision motion device. An optical route of line-scanning confocal spectroscopy is designed and verified by simulation. The LSCCS is composed of a white laser source, a chromatic confocal optics, and a self-developed spectrometer. The chromatic confocal optics consists of a slit, a chromatic lens (dispersive objective lens), and a beam splitter, and the spectrometer consists of an adjustable slit, a collimating lens, a blazed grating, a focusing lens, a CMOS, and an image processing circuit. The slit and the chromatic lens are designed for a line focus, and the polarizing beam splitter is selected to maximize the white light power collected by the CMOS. The motion device is made to realize the full-field 3D scanning. The key algorithms involved are developed to accurately restore the peak wavelength that includes the position information of the measured surface from the collected spectral image. Theoretical analysis and simulation…
- 19top 1.8%
Ultra-low-vibration closed-cycle cryogenic surface-electrode ion trap apparatus
T. Dubielzig, S. Halama, H. Hahn, G. Zarantonello, M. Niemann and 2 more
35 citationsOpen accessdoi:10.1063/5.0024423OpenAlex
Show abstractHide abstract
We describe the design, commissioning, and operation of an ultra-low-vibration closed-cycle cryogenic ion trap apparatus. One hundred lines for low-frequency signals and eight microwave/radio frequency coaxial feed-lines offer the possibility of implementing a small-scale ion-trap quantum processor or simulator. With all supply cables attached, more than 1.3 W of cooling power at 5 K is still available for absorbing energy from electrical pulses introduced to control ions. The trap itself is isolated from vibrations induced by the cold head using a helium exchange gas interface. The performance of the vibration isolation system has been characterized using a Michelson interferometer, finding residual vibration amplitudes on the order of 10 nm rms. Trapping of 9Be+ ions has been demonstrated using a combination of laser ablation and photoionization.
- 20top 1.8%
Feedback-controlled microbubble generator producing one million monodisperse bubbles per second
Benjamin van Elburg, Gonzalo Collado‐Lara, Gert‐Wim Bruggert, Tim Segers, Michel Versluis and 1 more
35 citationsOpen accessdoi:10.1063/5.0032140OpenAlex
Show abstractHide abstract
Monodisperse lipid-coated microbubbles are a promising route to unlock the full potential of ultrasound contrast agents for medical diagnosis and therapy. Here, we present a stand-alone lab-on-a-chip instrument that allows microbubbles to be formed with high monodispersity at high production rates. Key to maintaining a long-term stable, controlled, and safe operation of the microfluidic device with full control over the output size distribution is an optical transmission-based measurement technique that provides real-time information on the production rate and bubble size. We feed the data into a feedback loop and demonstrate that this system can control the on-chip bubble radius (2.5 μm–20 μm) and the production rate up to 106 bubbles/s. The freshly formed phospholipid-coated bubbles stabilize after their formation to a size approximately two times smaller than their initial on-chip bubble size without loss of monodispersity. The feedback control technique allows for full control over the size distribution of the agent and can aid the development of microfluidic platforms operated…
- 21top 1.9%
Impact and trends in embedding field programmable gate arrays and microcontrollers in scientific instrumentation
Marco Carminati, Graziella Scandurra
34 citationsdoi:10.1063/5.0050999OpenAlex
Show abstractHide abstract
Microcontrollers and field-programmable gate arrays have been largely leveraged in scientific instrumentation since decades. Recent advancements in the performance of these programmable digital devices, with hundreds of I/O pins, up to millions of logic cells, >10 Gb/s connectivity, and hundreds of MHz multiple clocks, have been accelerating this trend, extending the range of functions. The diversification of devices from very low-cost 8-bit microcontrollers up to 32-bit ARM-based ones and a system of chip combining programmable logic with processors make them ubiquitous in modern electronic systems, addressing diverse challenges from ultra-low power operation, with sub-µA quiescent current in sleep mode for portable and Internet of Things applications, to high-performance computing, such as in machine vision. In this Review, the main motivations (compactness, re-configurability, parallelization, low latency for sub-ns timing, and real-time control), the possible approaches of the adoption of embedded devices, and the achievable performances are discussed. Relevant examples of…
- 22top 2%
The Ice Chamber for Astrophysics–Astrochemistry (ICA): A new experimental facility for ion impact studies of astrophysical ice analogs
Péter Herczku, Duncan V. Mifsud, S. Ioppolo, Zoltán Juhász, Z. Kaňuchová and 9 more
34 citationsOpen accessdoi:10.1063/5.0050930OpenAlex
Show abstractHide abstract
The Ice Chamber for Astrophysics-Astrochemistry (ICA) is a new laboratory end station located at the Institute for Nuclear Research (Atomki) in Debrecen, Hungary. The ICA has been specifically designed for the study of the physico-chemical properties of astrophysical ice analogs and their chemical evolution when subjected to ionizing radiation and thermal processing. The ICA is an ultra-high-vacuum compatible chamber containing a series of IR-transparent substrates mounted on a copper holder connected to a closed-cycle cryostat capable of being cooled down to 20 K, itself mounted on a 360° rotation stage and a z-linear manipulator. Ices are deposited onto the substrates via background deposition of dosed gases. The ice structure and chemical composition are monitored by means of FTIR absorbance spectroscopy in transmission mode, although the use of reflectance mode is possible by using metallic substrates. Pre-prepared ices may be processed in a variety of ways. A 2 MV Tandetron accelerator is capable of delivering a wide variety of high-energy ions into the ICA, which simulates ice…
- 23top 2.1%
High-resolution inelastic x-ray scattering at the high energy density scientific instrument at the European X-Ray Free-Electron Laser
L. Wollenweber, Thomas R. Preston, Adrien Descamps, Valerio Cerantola, A. J. Comley and 25 more
34 citationsOpen access (CC-BY)doi:10.1063/5.0022886OpenAlex
Show abstractHide abstract
We introduce a setup to measure high-resolution inelastic x-ray scattering at the High Energy Density scientific instrument at the European X-Ray Free-Electron Laser (XFEL). The setup uses the Si (533) reflection in a channel-cut monochromator and three spherical diced analyzer crystals in near-backscattering geometry to reach a high spectral resolution. An energy resolution of 44 meV is demonstrated for the experimental setup, close to the theoretically achievable minimum resolution. The analyzer crystals and detector are mounted on a curved-rail system, allowing quick and reliable changes in scattering angle without breaking vacuum. The entire setup is designed for operation at 10 Hz, the same repetition rate as the high-power lasers available at the instrument and the fundamental repetition rate of the European XFEL. Among other measurements, it is envisioned that this setup will allow studies of the dynamics of highly transient laser generated states of matter.
- 24top 2.2%
Suppression of the vacuum space-charge effect in fs-photoemission by a retarding electrostatic front lens
Gerd Schönhense, Dmytro Kutnyakhov, Federico Pressacco, Michael Heber, Nils Wind and 25 more
33 citationsOpen accessdoi:10.1063/5.0046567OpenAlex
Show abstractHide abstract
The performance of time-resolved photoemission experiments at fs-pulsed photon sources is ultimately limited by the e–e Coulomb interaction, downgrading energy and momentum resolution. Here, we present an approach to effectively suppress space-charge artifacts in momentum microscopes and photoemission microscopes. A retarding electrostatic field generated by a special objective lens repels slow electrons, retaining the k-image of the fast photoelectrons. The suppression of space-charge effects scales with the ratio of the photoelectron velocities of fast and slow electrons. Fields in the range from −20 to −1100 V/mm for Ekin = 100 eV to 4 keV direct secondaries and pump-induced slow electrons back to the sample surface. Ray tracing simulations reveal that this happens within the first 40 to 3 μm above the sample surface for Ekin = 100 eV to 4 keV. An optimized front-lens design allows switching between the conventional accelerating and the new retarding mode. Time-resolved experiments at Ekin = 107 eV using fs extreme ultraviolet probe pulses from the free-electron laser FLASH…
- 25top 2.3%
Broadband femtosecond spectroscopic ellipsometry
Steffen Richter, Mateusz Rębarz, Oliver Herrfurth, Shirly Espinoza, Rüdiger Schmidt‐Grund and 1 more
31 citationsOpen access (CC-BY)doi:10.1063/5.0027219OpenAlex
Show abstractHide abstract
We present a setup for time-resolved spectroscopic ellipsometry in a pump-probe scheme using femtosecond laser pulses. As a probe, the system deploys supercontinuum white light pulses that are delayed with respect to single-wavelength pump pulses. A polarizer-sample-compensator-analyzer configuration allows ellipsometric measurements by scanning the compensator azimuthal angle. The transient ellipsometric parameters are obtained from a series of reflectance-difference spectra that are measured for various pump-probe delays and polarization (compensator) settings. The setup is capable of performing time-resolved spectroscopic ellipsometry from the near-infrared through the visible to the near-ultraviolet spectral range at 1.3 eV-3.6 eV. The temporal resolution is on the order of 100 fs within a delay range of more than 5 ns. We analyze and discuss critical aspects such as fluctuations of the probe pulses and imperfections of the polarization optics and present strategies deployed for circumventing related issues.
- 26top 2.4%
In situ synchrotron x-ray diffraction studies monitoring mechanochemical reactions of hard materials: Challenges and limitations
Tobias Rathmann, Hilke Petersen, Steffen Reichle, Wolfgang N. Schmidt, Amol P. Amrute and 2 more
30 citationsOpen access (CC-BY)doi:10.1063/5.0068627OpenAlex
Show abstractHide abstract
In situ monitoring of mechanochemical reactions of soft matter is feasible by synchrotron diffraction experiments. However, so far, reactions of hard materials in existing polymer milling vessels failed due to insufficient energy input. In this study, we present the development of a suitable setup for in situ diffraction experiments at a synchrotron facility. The mechanochemical transformation of boehmite, γ-AlOOH, to corundum, α-Al2O3, was chosen as a model system. The modifications of the mill’s clamping system and the vessels themselves were investigated separately. Starting from a commercially available Retsch MM 400 shaker mill, the influence of the geometrical adaptation of the setup on the milling process was investigated. Simply extending the specimen holder proved to be not sufficient because changes in mechanical forces need to be accounted for in the construction of optimized extensions. Milling vessels that are suitable for diffraction experiments and also guarantee the required energy input as well as mechanical stability were developed. The vessels consist of a steel…
- 27top 2.5%
A new setup for low-temperature gas-phase ion fluorescence spectroscopy
Christina Kjær, Jeppe Langeland, Thomas Toft Lindkvist, Emma Rostal Sørensen, Mark H. Stockett and 2 more
30 citationsOpen access (OTHER-OA)doi:10.1063/5.0038880OpenAlex
Show abstractHide abstract
Here, we present a new instrument named LUNA2 (LUminescence iNstrument in Aarhus 2), which is purpose-built to measure dispersed fluorescence spectra of gaseous ions produced by electrospray ionization and cooled to low temperatures (<100 K). LUNA2 is, as an earlier room-temperature setup (LUNA), optimized for a high collection efficiency of photons and includes improvements based on our operational experience with LUNA. The fluorescence cell is a cylindrical Paul trap made of copper with a hole in the ring electrode to permit laser light to interact with the trapped ions, and one end-cap electrode is a mesh grid combined with an aspheric condenser lens. The entrance and exit electrodes are both in physical contact with the liquid-nitrogen cooling unit to reduce cooling times. Mass selection is done in a two-step scheme where, first, high-mass ions are ejected followed by low-mass ions according to the Mathieu stability region. This scheme may provide a higher mass resolution than when only one DC voltage is used. Ions are irradiated by visible light delivered from a nanosecond…
- 28top 2.6%
Robot grasping method optimization using improved deep deterministic policy gradient algorithm of deep reinforcement learning
Hongxu Zhang, Fei Wang, Jianhui Wang, Ben Cui
29 citationsdoi:10.1063/5.0034101OpenAlex
Show abstractHide abstract
Robot grasping has become a very hot research field so that the requirements for robot operation are getting higher and higher. In previous research studies, the use of traditional target detection algorithms for grasping is often very inefficient, and this article is dedicated to improving the deep reinforcement learning algorithm to improve the grasping efficiency and solve the problem of robots dealing with the impact of unknown disturbances on grasping. Using the characteristic that deep reinforcement learning actively explores the unknown environment, a Gaussian parameter Deep Deterministic Policy Gradient (Gaussian-DDPG) algorithm based on the Importance-Weighted Autoencoder (IWAE) is proposed to realize the robot's autonomous learning of the grasping task. Traditional coordinate positioning methods and deep learning methods have poor grasping effects for disturbed situations (such as the movement of the target object). The IWAE algorithm is used to compress the high-dimensional information of the original visual input to the hidden space and pass it to the deep reinforcement…
- 29top 2.7%
Embedded heating, ventilation, and air-conditioning control systems: From traditional technologies toward radar advanced sensing
Emanuele Cardillo, Changzhi Li, Alina Caddemi
28 citationsdoi:10.1063/5.0044673OpenAlex
Show abstractHide abstract
This paper comprehensively reviews the state of the art of Heating, Ventilation, and Air-Conditioning (HVAC) control sensing. The topic has broad impacts on society, by affecting energy consumption, Earth's climate, and the environmental health. Great effort was taken by researchers to study and test new technologies and methodologies for improving HVAC energy efficiency, but this large amount of works is often fragmentary, and a complete and recent review paper does not yet exist. This paper aims at filling this gap by clarifying the key points of HVAC sensing, the main technologies, and their pros and cons. The advancement in this sector is fueled by the premium performance of the embedded systems exploited as sensors and their beneficial features. The state of the art of the available solutions has been summarized with the purpose of fueling and better organizing the research effort on this hot topic. Particular attention has been paid to investigate not only the performance and reliability of the current systems but also the advanced features that can be provided by the newly…
- 30top 2.7%
Simultaneous ambient pressure x-ray photoelectron spectroscopy and grazing incidence x-ray scattering in gas environments
Heath Kersell, Pengyuan Chen, Henrique P. Martins, Qiyang Lu, Felix Brauße and 7 more
28 citationsOpen accessdoi:10.1063/5.0044162OpenAlex
Show abstractHide abstract
We have developed an experimental system to simultaneously measure surface structure, morphology, composition, chemical state, and chemical activity for samples in gas phase environments. This is accomplished by simultaneously measuring x-ray photoelectron spectroscopy (XPS) and grazing incidence x-ray scattering in gas pressures as high as the multi-Torr regime while also recording mass spectrometry. Scattering patterns reflect near-surface sample structures from the nano-scale to the meso-scale, and the grazing incidence geometry provides tunable depth sensitivity of structural measurements. Scattered x rays are detected across a broad range of angles using a newly designed pivoting-UHV-manipulator for detector positioning. At the same time, XPS and mass spectrometry can be measured, all from the same sample spot and under ambient conditions. To demonstrate the capabilities of this system, we measured the chemical state, composition, and structure of Ag-behenate on a Si(001) wafer in vacuum and in O2 atmosphere at various temperatures. These simultaneous structural, chemical, and…
- 31top 2.8%
Fast-ion orbit sensitivity of neutron emission spectroscopy diagnostics
Henrik Järleblad, L. Stagner, M. Salewski, J. Eriksson, Stuart Benjamin and 4 more
28 citationsOpen accessdoi:10.1063/5.0040696OpenAlex
Show abstractHide abstract
Fast ions in fusion plasmas often leave characteristic signatures in the plasma neutron emission. Measurements of this emission are subject to the phase-space sensitivity of the diagnostic, which can be mapped using weight functions. In this paper, we present orbit weight functions for the TOFOR and NE213 neutron diagnostics at the Joint European Torus, mapping their phase-space sensitivity in 3D orbit space. Both diagnostics are highly sensitive to fast ions that spend a relatively large fraction of their orbit transit times inside the viewing cone of the diagnostic. For most neutron energies, TOFOR is found to be relatively sensitive to potato orbits and heavily localized counter-passing orbits, as well as trapped orbits whose "banana tips" are inside the viewing cone of TOFOR. For the NE213-scintillator, the sensitivity is found to be relatively high for stagnation orbits.
- 32top 2.9%
A dual-magneto-optical-trap atom gravity gradiometer for determining the Newtonian gravitational constant
Dekai Mao, Xiao-Bing Deng, Hua-Qing Luo, Yaoyao Xu, Min-Kang Zhou and 2 more
27 citationsdoi:10.1063/5.0040701OpenAlex
Show abstractHide abstract
As part of a program to determine the gravitational constant G using multiple independent methods in the same laboratory, an atom gravity gradiometer is being developed. The gradiometer is designed with two magneto-optical traps to ensure both the fast simultaneous launch of two atomic clouds and an optimized configuration of source masses. Here, the design of the G measurement by atom interferometry is detailed, and the experimental setup of the atom gravity gradiometer is reported. A preliminary sensitivity of 3 × 10−9 g/Hz to differential gravity acceleration is obtained, which corresponds to 99 E/Hz (1 E = 10−9 s−2) for the gradiometer with a baseline of 0.3 m. This provides access to measuring G at the level of less than 200 parts per million in the first experimental stage.
- 33top 3%
Cell-phone camera Raman spectrometer
Dinesh Dhankhar, Anushka Nagpal, Peter M. Rentzepis
27 citationsdoi:10.1063/5.0046281OpenAlex
Show abstractHide abstract
In this report, we describe the design, construction, and operation of a cell-phone-based Raman and emission spectral detector, which when coupled to a diffraction grating and cell-phone camera system provides means for the detection, recording, and identification of chemicals, drugs, and biological molecules, in situ by means of their Raman and fluorescence spectra. The newly constructed cell-phone spectrometer system was used to record Raman spectra from various chemicals and biological molecules including the resonance enhanced Raman spectra of carrots and bacteria. In addition, we present the quantitative analysis of alcohol-water Raman spectra, performed using our cell-phone spectrometer. The designed and constructed system was also used for constructing Raman images of the samples by utilizing a position scanning stage in conjunction with the system. This compact and portable system is well suited for in situ field applications of Raman and fluorescence spectroscopy and may also be an integrated feature of future cell-phones.
- 34top 3.1%
System-on-chip upgrade of millimeter-wave imaging diagnostics for fusion plasma
Yilun Zhu, Jo-Han Yu, Guanying Yu, Y. Ye, Ying Chen and 12 more
27 citationsOpen accessdoi:10.1063/5.0040449OpenAlex
Show abstractHide abstract
Monolithic, millimeter wave "system-on-chip" technology has been employed in chip heterodyne radiometers in a newly developed Electron Cyclotron Emission Imaging (ECEI) system on the DIII-D tokamak for 2D electron temperature and fluctuation diagnostics. The system employs 20 horn-waveguide receiver modules each with customized W-band (75-110 GHz) monolithic microwave integrated circuit chips comprising a W-band low noise amplifier, a balanced mixer, a ×2 local oscillator (LO) frequency doubler, and two intermediate frequency amplifier stages in each module. Compared to previous quasi-optical ECEI arrays with Schottky mixer diodes mounted on planar antennas, the upgraded W-band array exhibits >30 dB additional gain and 20× improvement in noise temperature; an internal eight times multiplier chain is used to provide LO coupling, thereby eliminating the need for quasi-optical coupling. The horn-waveguide shielding housing avoids out-of-band noise interference on each module. The upgraded ECEI system plays an important role for absolute electron temperature and fluctuation measurements…
- 35top 3.2%
Adjusting single-axis acoustic levitators in real time using rainbow schlieren deflectometry
Víctor Contreras, Asier Marzo
27 citationsdoi:10.1063/5.0013347OpenAlex
Show abstractHide abstract
Acoustic levitation uses focused high-intensity airborne ultrasound to hold particles in mid-air. It is becoming an important tool for experiments in spectrometry, lab-on-a-droplet, and display technologies. Nowadays, arrays of multiple small transducers can be used to build acoustic levitators; however, their performance depends on the optimal alignment. This work describes a simple method capable of visualizing a 2D projection of the acoustic field in real time using rainbow schlieren deflectometry. Good agreement was found between the images obtained with this technique and simulations of the acoustic pressure. It was also found that the maximum amplitudes of the field were obtained with the levitator aligned so that the power consumption was minimum, showing another simple and affordable way to adjust the levitators. As a result of the alignment optimization, it was possible for the first time to levitate steel and mercury in a levitator constructed with off-the-shelf components. The schlieren technique was applied to the TinyLev acoustic levitation system, but it can be applied…
- 36top 3.3%
Laboratory plasma devices for space physics investigation
Yu Liu, Peiyun Shi, Xiao Zhang, Jiuhou Lei, Weixing Ding
26 citationsdoi:10.1063/5.0021355OpenAlex
Show abstractHide abstract
In the past decades, laboratory experiments have contributed significantly to the exploration of the fundamental physics of space plasmas. Since 1908, when Birkeland invented the first terrella device, numerous experimental apparatuses have been designed and constructed for space physics investigations, and beneficial achievements have been gained using these laboratory plasma devices. In the present work, we review the initiation, development, and current status of laboratory plasma devices for space physics investigations. The notable experimental apparatuses are categorized and discussed according to the central scientific research topics they are related to, such as space plasma waves and instabilities, magnetic field generation and reconnection, and modeling of the Earth's and planetary space environments. The characteristics of each device, including the plasma configuration, plasma generation, and control method, are highlighted and described in detail. In addition, their contributions to reveal the underlying physics of space observations are also briefly discussed. For the…
- 37top 3.4%
A new tangential gamma-ray spectrometer for fast ion measurements in deuterium and deuterium–tritium plasmas of the Joint European Torus
M. Nocente, T. Craciunescu, G. Gorini, V. Kiptily, M. Tardocchi and 17 more
26 citationsOpen access (OTHER-OA)doi:10.1063/5.0043806OpenAlex
Show abstractHide abstract
A new tangential gamma-ray spectrometer has been developed for fast ion measurements in deuterium and deuterium–tritium plasmas of the Joint European Torus (JET). The instrument is based on a LaBr3 crystal with a photo-multiplier tube and replaces a pre-existing bismuth germanate detector, providing enhanced energy resolution and a counting rate capability in the MHz range. The line of sight is equipped with a LiH attenuator, which reduces the background due to 14 MeV neutron interactions with the crystal by more than two orders of magnitude and enables the observation of gamma-ray emission from confined α particles in JET deuterium–tritium plasmas. Thanks to its tangential line of sight, the detector can distinguish co- and counter-passing ions. The performance of the instrument is demonstrated through the results of recent JET fast ion experiments in deuterium plasmas.
- 38top 3.5%
Multi-chord IR–visible two-color interferometer on KSTAR
J.-W. Juhn, K. C. Lee, T. G. Lee, H. M. Wi, Y. S. Kim and 2 more
26 citationsdoi:10.1063/5.0043811OpenAlex
Show abstractHide abstract
Major parts of an IR-visible two-color interferometer (TCI) on KSTAR have been upgraded for the multi-chord operation: (1) a diode-pumped-solid-state (DPSS) laser (660 nm) replacing the former HeNe laser (633 nm), (2) vacuum-compatible vibration isolator with titanium retro-reflectors, and (3) full digital phase comparator for multi-chord real-time density signals. The commercial compact DPSS laser suits the multiple chord configuration with its strong beam power (500 mW) and long coherent length (>100 m). Ti retro-reflectors are mounted on vacuum-compatible vibration isolators. The isolators are essential for the visible beams to avoid any fringe skips due to their short wavelength, considering the speed of the mechanical vibration (up to hundreds of μm). Field-programmable-gate-array (FPGA) modules count the entire fringes fast enough with a signal output rate up to 1.25 MHz, solving the fringe skip issues. The FPGA module enables the full digital processing of the phase comparator with a CORDIC algorithm after the sampling rate of 160 MS/s for the 40 MHz intermediate frequency of…
- 39top 3.5%
Upgrades to the ion cyclotron emission diagnostic on the DIII-D tokamak
Genevieve DeGrandchamp, K. E. Thome, William W. Heidbrink, Ian Holmes, Robert I. Pinsker
26 citationsOpen accessdoi:10.1063/5.0040597OpenAlex
Show abstractHide abstract
The ion cyclotron emission diagnostic on the DIII-D tokamak comprises seven single-turn loops that measure high-frequency (1-100 MHz) magnetic field fluctuations that are often excited by energetic particles in the plasma. The raw voltage signals induced in the loops in response to these fluctuations travel through a series of cables, isolation transformer DC blocks, low-pass filters, and finally a digitizer before being analyzed in frequency space. The diagnostic has been recently upgraded, most notably to include four additional graphite tile loops and a new eight-channel digitizer. The previous three loops are all on the low-field side of the tokamak. The measurement capabilities of the system have been expanded by the addition of a new horizontally oriented loop on the low-field side, an additional toroidal loop on the low-field side, and two toroidal loops on the high-field side. These loops will be used to provide approximate mode polarization, improved toroidal mode number calculations, and information on modes in inward-shifted plasmas, respectively.
- 40top 3.6%
High voltage nanosecond pulse generator based on avalanche transistor Marx bank circuit and linear transformer driver
Zichen Deng, Qi Yuan, Saikang Shen, Jiaqi Yan, Yanan Wang and 1 more
26 citationsdoi:10.1063/5.0042523OpenAlex
Show abstractHide abstract
Avalanche transistor Marx bank circuits (MBCs) are widely used in high voltage repetitive nanosecond pulse generators, but problems exist with respect to increasing the output voltage due to the limited pulsed current. Accordingly, a novel topology based on an avalanche transistor MBC combined with a linear transformer driver is proposed, the latter of which exhibits advantageous stress distribution and modular structure. A four-module prototype with four units in each module is developed in the laboratory. The output characteristics are investigated by varying important parameters such as the main capacitance, the number of conducting units, the number of cascaded modules, and the trigger signal time delay. The test results verify the validity of the proposed topology. For a 50 Ω resistive load, the prototype can generate pulses with an amplitude of 10.9 kV, a rise time of 3.3 ns, and a voltage superposition efficiency of 89%. The topology proposed in this paper may help to provide a method to further improve the output performance of avalanche transistor MBCs.
- 41top 3.7%
A built-in coil system attached to the inside walls of a magnetically shielded room for generating an ultra-high magnetic field homogeneity
Tianhao Liu, A. Schnabel, Jens Voigt, Wolfgang Kilian, Zhiyin Sun and 2 more
26 citationsdoi:10.1063/5.0027848OpenAlex
Show abstractHide abstract
The homogeneity of the magnetic field generated by a coil inside a magnetic shield is essential for many applications, such as ultra-low field nuclear magnetic resonance or spin precession experiments. In the course of upgrading the Berlin Magnetically Shielded Room (BMSR-2) with a new inserted Permalloy layer of side length 2.87 m, we designed a built-in coil consisting of four identical square windings attached to its inside walls. The spacings of the four windings were optimized using a recently developed semi-analytic model and finite element analysis. The result reveals a strong dependence of the field homogeneity on the asymmetric placement of the inner two windings and on the chosen material permeability value μs. However, our model calculations also show that these experimental variations can be counterbalanced by an adjustment of the inner winding positions in the millimeter range. Superconducting quantum interference device-based measurements yield for our implementation after fine adjustments of a single winding position a maximum field change of less than 10 pT for a…
- 42top 3.8%
Broadband high-energy resolution hard x-ray spectroscopy using transition edge sensors at SPring-8
Shinya Yamada, Yuto Ichinohe, H. Tatsuno, Ryota Hayakawa, Hirotaka Suda and 25 more
26 citationsOpen access (CC-BY)doi:10.1063/5.0020642OpenAlex
Show abstractHide abstract
We have succeeded in operating a transition-edge sensor (TES) spectrometer and evaluating its performance at the SPring-8 synchrotron x-ray light source. The TES spectrometer consists of a 240 pixel National Institute of Standards and Technology (NIST) TES system, and 220 pixels are operated simultaneously with an energy resolution of 4 eV at 6 keV at a rate of ∼1 c/s pixel−1. The tolerance for high count rates is evaluated in terms of energy resolution and live time fraction, leading to an empirical compromise of ∼2 × 103 c/s (all pixels) with an energy resolution of 5 eV at 6 keV. By utilizing the TES’s wideband spectroscopic capability, simultaneous multi-element analysis is demonstrated for a standard sample. We conducted x-ray absorption near-edge structure (XANES) analysis in fluorescence mode using the TES spectrometer. The excellent energy resolution of the TES enabled us to detect weak fluorescence lines from dilute samples and trace elements that have previously been difficult to resolve due to the nearly overlapping emission lines of other dominant elements. The…
- 43top 3.9%
Achieving smooth motion and high-speed for piezoelectric stick–slip actuator based on the two-stage lever principle
Honglong Li, Jiru Wang, Zhi Ming Xu, Feng Qin, Zhaoxin Wang and 1 more
25 citationsdoi:10.1063/5.0070960OpenAlex
Show abstractHide abstract
With the development of the precision manufacturing industry, actuators' performance requirements are increasingly demanding. However, stick-slip actuators still have the problems of backward motion and low motion speed at low frequencies. In this paper, to decrease the backward motion and achieve high speed at low frequencies, a linear piezoelectric stick-slip actuator is designed based on the two-stage lever principle. Theoretical and numerical investigations are used to optimize the flexible hinge of the stick-slip actuator. Experimental results indicate that the motion slider can achieve a smooth motion. The backward rate can even drop to 0. The maximum motion speed was 124.83 mm/s at 1600 Hz. The motion speed of the designed actuator was higher than that of previous stick-slip actuators at the same frequency. In addition, the load capacity of the prototype is tested. Based on different loads, the load matching is achieved by an auxiliary piezoelectric-stack, where the maximum horizontal load was 2.3 N. According to the comparison with previous actuators, the designed prototype…
- 44top 4%
Millikelvin scanning tunneling microscope at 20/22 T with a graphite enabled stick–slip approach and an energy resolution below 8 μ eV: Application to conductance quantization at 20 T in single atom point contacts of Al and Au and to the charge density wave of 2H–NbSe2
Marta Fernández-Lomana, Beilun Wu, Francisco Martín-Vega, Raquel Sánchez-Barquilla, Rafael Álvarez Montoya and 6 more
25 citationsOpen accessdoi:10.1063/5.0059394OpenAlex
Show abstractHide abstract
We describe a scanning tunneling microscope (STM) that operates at magnetic fields up to 22 T and temperatures down to 80 mK. We discuss the design of the STM head, with an improved coarse approach, the vibration isolation system, and efforts to improve the energy resolution using compact filters for multiple lines. We measure the superconducting gap and Josephson effect in aluminum and show that we can resolve features in the density of states as small as 8 μeV. We measure the quantization of conductance in atomic size contacts and make atomic resolution and density of states images in the layered material 2H–NbSe2. The latter experiments are performed by continuously operating the STM at magnetic fields of 20 T in periods of several days without interruption.
- 45top 4.1%
High-repetition rate solid target delivery system for PW-class laser–matter interaction at ELI Beamlines
F. P. Condamine, N. Jourdain, J.-C. Hernandez, Mark Taylor, H. Bohlin and 6 more
25 citationsdoi:10.1063/5.0053281OpenAlex
Show abstractHide abstract
L3-HAPLS (High-repetition-rate Advanced Petawatt Laser System) at ELI (Extreme Light Infrastructure) Beamlines currently delivers 0.45 PW pulses (12 J in 27 fs) at 3.3 Hz repetition rate. A fresh target surface for every shot was placed at the laser focus using an in-house tape target system designed to withstand large laser intensities and energies. It has been tested for different material thicknesses (25 and 7.6 µm), while L3-HAPLS delivered laser shots for energies ranging from 1 to 12 J. A technical description of the tape target system is given. The device can be used in diverse geometries needed for laser-matter interaction studies by providing an ≈300° free angle of view on the target in the equatorial plane. We show experimental data demonstrating the shot-to-shot stability of the device. An x-ray crystal spherical spectrometer was set up to measure the Kα yield stability, while a GHz H-field probe was used to check the shot-to-shot electromagnetic pulse generation. Finally, we discuss short and mid-term future improvements of the tape target system for efficient user…
- 46top 4.2%
Phase lag index-based graph attention networks for detecting driving fatigue
Zhongmin Wang, Yupeng Zhao, Yan Li He, Jie Zhang
24 citationsdoi:10.1063/5.0056139OpenAlex
Show abstractHide abstract
It is important to understand the changes in the characteristics of the brain network in the state of driving fatigue and to reveal the pattern of functional connectivity between brain regions when fatigue occurs. This paper proposes a method for the detection of driving fatigue based on electroencephalogram (EEG) signals using a phase lag index graph attention network (PLI-GAT). Phase synchronization between EEG signals is a key attribute for establishing communication links among different regions of the brain, and so, the PLI is used to construct a functional brain network reflecting the relationship between EEG signals from different channels. Multi-channel EEG time-frequency features are then modeled as graph data, and the driving fatigue monitoring model is trained using a GAT. Compared with traditional graph neural networks, the GAT applies an aggregation operation to adjacent EEG channel features through the attention mechanism. This enables the adaptive assignment of different neighbor weights, which greatly improves the expressiveness of the graph neural network model. The…
- 47top 4.3%
Development of an 11-channel multi wavelength imaging diagnostic for divertor plasmas in MAST Upgrade
Xiande Feng, Ariadna Calcines, Ray M. Sharples, B. Lipschultz, A. Perek and 8 more
24 citationsOpen access (CC-BY)doi:10.1063/5.0043533OpenAlex
Show abstractHide abstract
Divertor detachment and alternative divertor magnetic geometries are predicted to be promising approaches to handle the power exhaust of future fusion devices. In order to understand the detachment process caused by volumetric losses in alternative divertor magnetic geometries, a Multi-Wavelength Imaging (MWI) diagnostic has recently been designed and built for the Mega Amp Spherical Tokamak Upgrade. The MWI diagnostic will simultaneously capture 11 spectrally filtered images of the visible light emitted from divertor plasmas and provide crucial knowledge for the interpretation of observations and modeling efforts. This paper presents the optical design, mechanical design, hardware, and test results of an 11-channel MWI system with a field of view of 40°. The optical design shows better than 5 mm FWHM spatial resolution at the plasma on all 11 channels across the whole field of view. The spread of angle of incidence on the surface of each filter is also analyzed to inform the bandwidth specification of the interference filters. The results of the initial laboratory tests demonstrate…
- 48top 4.4%
Determining 1D fast-ion velocity distribution functions from ion cyclotron emission data using deep neural networks
Bo Simmendefeldt Schmidt, M. Salewski, Bernard Reman, Richard O. Dendy, D. Moseev and 4 more
24 citationsOpen accessdoi:10.1063/5.0041456OpenAlex
Show abstractHide abstract
of the fast ions triggering the ICE is modeled using a two-layer deep neural network. The network architecture (number of layers and number of computational nodes in each layer) and hyperparameters (learning rate and number of learning iterations) are fine-tuned using a bottom-up approach based on cross-validation. Thus, the optimal mapping gs;θ of the neural network in terms of the number of nodes, the number of layers, and the values of the hyperparameters, where θ is the learned model parameters, is determined by comparing many different configurations of the network on the same training and test set and choosing the best one based on its average test error. The training and test sets are generated by computing random ICE velocity distribution functions f and their corresponding ICE signals s by modeling the relationship as the linear matrix equation Wf = s. The simulated ICE signals are modeled as edge ICE signals at LHD. The network predictions for f based on ICE signals s are on many simulated ICE signal examples closer to the true velocity distribution function than that…
- 49top 4.4%
Collective optical Thomson scattering in pulsed-power driven high energy density physics experiments (invited)
L. Suttle, Jack Hare, Jack Halliday, S. Merlini, D. R. Russell and 5 more
24 citationsOpen access (CC-BY)doi:10.1063/5.0041118OpenAlex
Show abstractHide abstract
Optical collective Thomson scattering (TS) is used to diagnose magnetized high energy density physics experiments at the Magpie pulsed-power generator at Imperial College London. The system uses an amplified pulse from the second harmonic of a Nd:YAG laser (3 J, 8 ns, 532 nm) to probe a wide diversity of high-temperature plasma objects, with densities in the range of 1017–1019 cm−3 and temperatures between 10 eV and a few keV. The scattered light is collected from 100 μm-scale volumes within the plasmas, which are imaged onto optical fiber arrays. Multiple collection systems observe these volumes from different directions, providing simultaneous probing with different scattering K-vectors (and different associated α-parameters, typically in the range of 0.5–3), allowing independent measurements of separate velocity components of the bulk plasma flow. The fiber arrays are coupled to an imaging spectrometer with a gated intensified charge coupled device. The spectrometer is configured to view the ion-acoustic waves of the collective Thomson scattered spectrum. Fits to the spectra with…
- 50top 4.5%
A 4He vector zero-field optically pumped magnetometer operated in the Earth-field
F. Bertrand, Thomas Jäger, Axel Boness, William Fourcault, Gwenael Le Gal and 3 more
23 citationsOpen access (OTHER-OA)doi:10.1063/5.0062791OpenAlex
Show abstractHide abstract
Low intrinsic noise, high bandwidth, and high accuracy vector magnetometers are key components for many ground or space geophysical applications. Here, we report the design and the test of a 4He vector optically pumped magnetometer specifically dedicated to these needs. It is based on a parametric resonance magnetometer architecture operated in the Earth magnetic field with closed-loop compensation of the three components of the magnetic field. It provides offset-free vector measurements in a ±70 μT range with a DC to 1 kHz bandwidth. We demonstrate a vector sensitivity up to 130 fT/√Hz, which is about ten times better than the best available fluxgate magnetometers currently available for the same targeted applications.
How to read this list
The cohort is every article, review and book chapter OpenAlex attributes to Review of Scientific Instruments with publication year 2021, excluding retracted works and paratext such as editorials and errata. The top 50 by citation count are listed; the percentile is the rank divided by the cohort size. 50 of the 50 entries have an abstract in OpenAlex. Counts were read on 29 October 2026 and will not be updated on this page, so a quoted rank stays verifiable. Full rules on the methodology page.
Other journals, same idea
Work with these 25 papers in Kahubi
- The papers land in your library with their DOIs
- Ask anything across all of them, with citations
- Draft a literature review from the same sources
Free plan, no card. Your files stay private unless you share them.
Reading several of these?
Kahubi reads papers with you, keeps every citation traceable and drafts with sources you can check. Free plan, no card.