Most-cited articles · 2018

The 50 most-cited articles in Review of Scientific Instruments, 2018

Ranked by OpenAlex citation count on 29 October 2026, out of 1,307 eligible articles Review of Scientific Instruments published in 2018. Ranks are frozen; this page will not change. Number one, with 162 citations: An instrument for in situ time-resolved X-ray imaging and diffraction of laser powder bed fusion additive manufacturing processes.

Cohort
1,307 articles
Listed
Top 50 (3.8%)
Open access
36 of 50
Snapshot
2026-10-29

The most-cited articles from Review of Scientific Instruments in 2018 cluster around a few themes. Instrumentation for in situ and operando measurement features prominently, led by "An instrument for in situ time-resolved X-ray imaging and diffraction of laser powder bed fusion additive manufacturing processes" with 162 citations. Magnetic field generation and plasma diagnostics also rank highly, including "Record indoor magnetic field of 1200 T generated by electromagnetic flux-compression" (153 citations) and several papers on fusion-relevant diagnostics. Neutron scattering instrumentation forms a third group, represented by suite-level reviews of powder and single-crystal diffractometers at Oak Ridge National Laboratory.

The ranking offers a neutral snapshot of instrumentation research that drew the most citation attention in 2018. Readers can use the list to identify recurring areas such as additive manufacturing, plasma and fusion diagnostics, neutron scattering, and precision metrology, and to locate the underlying articles for further detail.

Introduction written from the titles and abstracts on this list. Every figure below is the source.

Ask about these papers

Grounded in this list only, with sources.

3 of 3 free questions left today, no account needed
  1. 1
    top 0.1%

    An instrument for in situ time-resolved X-ray imaging and diffraction of laser powder bed fusion additive manufacturing processes

    Nicholas P. Calta, Jenny Wang, Andrew M. Kiss, Aiden A. Martin, Philip J. Depond and 10 more

    162 citationsOpen access (CC-BY)doi:10.1063/1.5017236OpenAlex

    Show abstract

    In situ X-ray-based measurements of the laser powder bed fusion (LPBF) additive manufacturing process produce unique data for model validation and improved process understanding. Synchrotron X-ray imaging and diffraction provide high resolution, bulk sensitive information with sufficient sampling rates to probe melt pool dynamics as well as phase and microstructure evolution. Here, we describe a laboratory-scale LPBF test bed designed to accommodate diffraction and imaging experiments at a synchrotron X-ray source during LPBF operation. We also present experimental results using Ti-6Al-4V, a widely used aerospace alloy, as a model system. Both imaging and diffraction experiments were carried out at the Stanford Synchrotron Radiation Lightsource. Melt pool dynamics were imaged at frame rates up to 4 kHz with a ∼1.1 μm effective pixel size and revealed the formation of keyhole pores along the melt track due to vapor recoil forces. Diffraction experiments at sampling rates of 1 kHz captured phase evolution and lattice contraction during the rapid cooling present in LPBF within a ∼50 ×…

  2. 2
    top 0.2%

    Record indoor magnetic field of 1200 T generated by electromagnetic flux-compression

    Daisuke Nakamura, Akihiko Ikeda, H. Sawabe, Yasuhiro H. Matsuda, S. Takeyama

    153 citationsdoi:10.1063/1.5044557OpenAlex

    Show abstract

    A peak field of 1200 T was generated by the electromagnetic flux-compression (EMFC) technique with a newly developed megagauss generator system. Magnetic fields closely up to the turn-around peak were recorded by a reflection-type Faraday rotation magnetic-field optical-fiber probe. The performance was analyzed and compared with data obtained by the preceding EMFC experiments to show a significant increase in the liner imploding speed of up to 5 km/s.

  3. 3
    top 0.3%

    A suite-level review of the neutron powder diffraction instruments at Oak Ridge National Laboratory

    Stuart Calder, Ke An, R. Boehler, Clarina dela Cruz, Matthias Frontzek and 12 more

    139 citationsOpen access (CC-BY)doi:10.1063/1.5033906OpenAlex

    Show abstract

    The suite of neutron powder diffractometers at Oak Ridge National Laboratory (ORNL) utilizes the distinct characteristics of the Spallation Neutron Source and High Flux Isotope Reactor to enable the measurements of powder samples over an unparalleled regime at a single laboratory. Full refinements over large Q ranges, total scattering methods, fast measurements under changing conditions, and a wide array of sample environments are available. This article provides a brief overview of each powder instrument at ORNL and details the complementarity across the suite. Future directions for the powder suite, including upgrades and new instruments, are also discussed.

  4. 4
    top 0.4%

    A novel laboratory-based hard X-ray photoelectron spectroscopy system

    Anna Regoutz, Manfred Mascheck, T. Wiell, Susanna K. Eriksson, Cristopher Liljenberg and 4 more

    96 citationsOpen access (CC-BY)doi:10.1063/1.5039829OpenAlex

    Show abstract

    Hard X-ray photoelectron spectroscopy (HAXPES) has seen continuous development since the first experiments in the 1970s. HAXPES systems are predominantly located at synchrotron sources due to low photoionization cross sections necessitating high X-ray intensities, which limits the technique’s availability to a wide range of users and potential applications. Here, a new laboratory-based instrument capable of delivering monochromated X-rays with an energy of 9.25 keV and a microfocused 30 × 45 μm2 X-ray spot is introduced. The system gives an excellent energy resolution of below 500 meV coupled with good X-ray intensity. It allows stable measurements under grazing incidence conditions to maximise signal intensities. This article outlines the instrument behavior, showcases applications including bulk and multilayer measurements, and describes the overall performance of the spectrometer. This system presents an alternative to synchrotron-based experimental end stations and will help expand the number and range of HAXPES experiments performed in the future.

  5. 5
    top 0.4%

    Power stabilization of a diode laser with an acousto-optic modulator

    François Tricot, Duy‐Hà Phung, M. Lours, Stéphane Guérandel, Emeric de Clercq

    95 citationsOpen accessdoi:10.1063/1.5046852OpenAlex

    Show abstract

    Laser power fluctuations can significantly reduce the device performances in various applications. High frequency fluctuations impact the signal-to-noise ratio, while slow variations can reduce the device repeatability or accuracy. Here we report experimental investigations on the power stabilization of a diode laser with an acousto-optic modulator. In the frequency domain, the relative power noise is reduced at the level of 2.2 × 10−8 Hz−1/2 in the range 1-100 kHz. The slow variations are studied in the time domain. The relative Allan standard deviation is measured at the level of 6 × 10−7 at 100 s averaging time. Above 100 s, the instability increases and reaches 2 × 10−6 at 10 000 s.

  6. 6
    top 0.5%

    The Heidelberg compact electron beam ion traps

    P. Micke, Steffen Kühn, L. Buchauer, James Robert Harries, Thore Mainart Bücking and 14 more

    91 citationsOpen access (CC-BY)doi:10.1063/1.5026961OpenAlex

    Show abstract

    Electron beam ion traps (EBITs) are ideal tools for both production and study of highly charged ions (HCIs). In order to reduce their construction, maintenance, and operation costs, we have developed a novel, compact, room-temperature design, the Heidelberg Compact EBIT (HC-EBIT). Four already commissioned devices operate at the strongest fields (up to 0.86 T) reported for such EBITs using permanent magnets, run electron beam currents up to 80 mA, and energies up to 10 keV. They demonstrate HCI production, trapping, and extraction of pulsed Ar16+ bunches and continuous 100 pA ion beams of highly charged Xe up to charge state 29+, already with a 4 mA, 2 keV electron beam. Moreover, HC-EBITs offer large solid-angle ports and thus high photon count rates, e.g., in x-ray spectroscopy of dielectronic recombination in HCIs up to Fe24+, achieving an electron-energy resolving power of E/ΔE > 1500 at 5 keV. Besides traditional on-axis electron guns, we have also implemented a novel off-axis gun for laser, synchrotron, and free-electron laser applications, offering clear optical access along…

  7. 7
    top 0.6%

    Calibrated work function mapping by Kelvin probe force microscopy

    Pablo Arturo Fernandez Garrillo, Benjamin Grévin, Nicolas Chevalier, Łukasz Borowik

    88 citationsOpen accessdoi:10.1063/1.5007619OpenAlex

    Show abstract

    We propose and demonstrate the implementation of an alternative work function tip calibration procedure for Kelvin probe force microscopy under ultrahigh vacuum, using monocrystalline metallic materials with known crystallographic orientation as reference samples, instead of the often used highly oriented pyrolytic graphite calibration sample. The implementation of this protocol allows the acquisition of absolute and reproducible work function values, with an improved uncertainty with respect to unprepared highly oriented pyrolytic graphite-based protocols. The developed protocol allows the local investigation of absolute work function values over nanostructured samples and can be implemented in electronic structures and devices characterization as demonstrated over a nanostructured semiconductor sample presenting Al0.7Ga0.3As and GaAs layers with variable thickness. Additionally, using our protocol we find that the work function of annealed highly oriented pyrolytic graphite is equal to 4.6 ± 0.03 eV.

  8. 8
    top 0.7%

    Advanced platform for the in-plane ZT measurement of thin films

    Vincent Linseis, F. Völklein, Heiko Reith, Kornelius Nielsch, Peter Woias

    86 citationsdoi:10.1063/1.5005807OpenAlex

    Show abstract

    The characterization of nanostructured samples with at least one restricted dimension like thin films or nanowires is challenging, but important to understand their structure and transport mechanism, and to improve current industrial products and production processes. We report on the 2nd generation of a measurement chip, which allows for a simplified sample preparation process, and the measurement of samples deposited from the liquid phase using techniques like spin coating and drop casting. The new design enables us to apply much higher temperature gradients for the Seebeck coefficient measurement in a shorter time, without influencing the sample holder’s temperature distribution. Furthermore, a two membrane correction method for the 3ω thermal conductivity measurement will be presented, which takes the heat loss due to radiation into account and increases the accuracy of the measurement results significantly. Errors caused by different sample compositions, varying sample geometries, and different heat profiles are avoided with the presented measurement method. As a showcase study…

  9. 9
    top 0.7%

    Calibration and energy measurement of optically levitated nanoparticle sensors

    Erik Hebestreit, Martin Frimmer, René Reimann, Christoph Dellago, Francesco Ricci and 1 more

    84 citationsOpen accessdoi:10.1063/1.5017119OpenAlex

    Show abstract

    Optically levitated nanoparticles offer enormous potential for precision sensing. However, as for any other metrology device, the absolute measurement performance of a levitated-particle sensor is limited by the accuracy of the calibration relating the measured signal to an absolute displacement of the particle. Here, we suggest and demonstrate calibration protocols for levitated-nanoparticle sensors. Our calibration procedures include the treatment of anharmonicities in the trapping potential, as well as a protocol using a harmonic driving force, which is applicable if the sensor is coupled to a heat bath of unknown temperature. Finally, using the calibration, we determine the center-of-mass temperature of an optically levitated particle in thermal equilibrium from its motion and discuss the optimal measurement time required to determine the said temperature.

  10. 10
    top 0.8%

    Contact angle measurement with a smartphone

    H. Chen, Jesus L. Muros-Cobos, Alidad Amirfazli

    81 citationsdoi:10.1063/1.5022370OpenAlex

    Show abstract

    In this study, a smartphone-based contact angle measurement instrument was developed. Compared with the traditional measurement instruments, this instrument has the advantage of simplicity, compact size, and portability. An automatic contact point detection algorithm was developed to allow the instrument to correctly detect the drop contact points. Two different contact angle calculation methods, Young-Laplace and polynomial fitting methods, were implemented in this instrument. The performance of this instrument was tested first with ideal synthetic drop profiles. It was shown that the accuracy of the new system with ideal synthetic drop profiles can reach 0.01% with both Young-Laplace and polynomial fitting methods. Conducting experiments to measure both static and dynamic (advancing and receding) contact angles with the developed instrument, we found that the smartphone-based instrument can provide accurate and practical measurement results as the traditional commercial instruments. The successful demonstration of use of a smartphone (mobile phone) to conduct contact angle…

  11. 11
    top 0.9%

    First experimental tests of powerful 250 GHz gyrotron for future fusion research and collective Thomson scattering diagnostics

    Gregory G. Denisov, Mikhail Yu. Glyavin, Andrey P. Fokin, Andrey N. Kuftin, Alexander I. Tsvetkov and 8 more

    80 citationsdoi:10.1063/1.5040242OpenAlex

    Show abstract

    A 250 GHz continuous-wave (CW) gyrotron has been developed at the IAP RAS jointly with GYCOM Ltd., as a prototype of the microwave source for the envisaged prospective nuclear fusion power plants (DEMO). The main applications of such a tube are electron cyclotron resonance heating and electron cyclotron resonance current drive of magnetically confined plasma as well as its diagnostics based on collective Thomson scattering in various reactors for controlled thermonuclear fusion (e.g., tokamaks and stellarators). The results of the preliminary experimental tests in a pulsed mode of operation are presented. The microwave power of up to 330 kW with an efficiency of 30% without collector depression was obtained. At an accelerating voltage of 55 kV and an electron beam current of 12.5 A (which corresponds to the design parameters for CW operation), the measured output power was about 200 kW. The TEM00 mode content evaluated at the tube output is not less than 98.6%.

  12. 12
    top 1%

    Infrared imaging systems for wall protection in the W7-X stellarator (invited)

    M. Jakubowski, P. Drewelow, Joris H. H. Fellinger, A. Puig Sitjes, G. A. Wurden and 16 more

    76 citationsOpen access (OTHER-OA)doi:10.1063/1.5038634OpenAlex

    Show abstract

    Wendelstein 7-X aims at quasi-steady state operation with up to 10 MW of heating power for 30 min. Power exhaust will be handled predominantly via 10 actively water cooled CFC (carbon-fiber-reinforced carbon) based divertor units designed to withstand power loads of 10 MW/m2 locally in steady state. If local loads exceed this value, a risk of local delamination of the CFC and failure of entire divertor modules arises. Infrared endoscopes to monitor all main plasma facing components are being prepared, and near real time software tools are under development to identify areas of excessive temperature rise, to distinguish them from non-critical events, and to trigger alarms. Tests with different cameras were made in the recent campaign. Long pulse operation enforces additional diagnostic design constraints: for example, the optics need to be thermally decoupled from the endoscope housing. In the upcoming experimental campaign, a graphite scraper element, in front of the island divertor throat, will be tested as a possible means to protect the divertor pumping gap edges during the…

  13. 13
    top 1%

    Absolute ion detection efficiencies of microchannel plates and funnel microchannel plates for multi-coincidence detection

    K. Fehre, D. Trojanowskaja, J. Gatzke, M. Kunitski, Florian Trinter and 9 more

    75 citationsOpen access (CC-BY)doi:10.1063/1.5022564OpenAlex

    Show abstract

    Modern momentum imaging techniques allow for the investigation of complex molecules in the gas phase by detection of several fragment ions in coincidence. For these studies, it is of great importance that the single-particle detection efficiency ε is as high as possible, as the overall efficiency scales with εn, i.e., the power of the number of detected particles. Here we present measured absolute detection efficiencies for protons of several micro-channel plates (MCPs), including efficiency enhanced “funnel MCPs.” Furthermore, the relative detection efficiency for two-, three-, four-, and five-body fragmentation of CHBrClF has been examined. The “funnel” MCPs exhibit an efficiency of approximately 90%, gaining a factor of 24 (as compared to “normal” MCPs) in the case of a five-fold ion coincidence detection.

  14. 14
    top 1.1%

    Automatic contactless injection, transportation, merging, and ejection of droplets with a multifocal point acoustic levitator

    Marco A. B. Andrade, Thales S. A. Camargo, Asier Marzo

    73 citationsOpen accessdoi:10.1063/1.5063715OpenAlex

    Show abstract

    We present an acoustic levitation system that automatically injects, transports, merges and ejects liquid droplets in mid-air. The system consists of a phased array operating at 40 kHz on top of a plane reflector. The phase array generates multiple focal points at independent positions that form standing waves between the array and the reflector. In the reflector there is an inlet for a piezoelectric droplet injector which automatically inserts liquid droplets at the lower pressure nodes of the standing waves, and a hole that serves as an outlet for ejecting the processed droplets out of the system. Simulations of the acoustic radiation potential acting on the levitating droplets are in good agreement with the experiments. High-speed footage captured the functioning of the system in four fluidic operations: injection, transport, merging and ejection of liquid droplets. Having these operations integrated reliably into a single automatic system paves the way for the adoption of mid-air acoustophoretic processing in biological, chemical and pharmaceutical applications.

  15. 15
    top 1.2%

    A multi-species powder dropper for magnetic fusion applications

    A. Nagy, A. Bortolon, D. Mauzey, E. Wolfe, E.P. Gilson and 5 more

    71 citationsOpen accessdoi:10.1063/1.5039345OpenAlex

    Show abstract

    We present a device for controlled injection of a variety of materials in powder form. The system implements four independent feeder units, arranged to share a single vertical drop tube. Each unit consists of a 80 ml reservoir, coupled to a horizontal linear trough, where a layer of powder is advanced by piezo-electric agitation at a speed proportional to the applied voltage, until it falls into a drop tube. The dropper has been tested with a number of impurities of low (B, BN, C), intermediate (Si, SiC), and high Z (Sn) and a variety of microscopic structures (flakes, spheres, rocks) and sizes (5-200 μm). For low Z materials, drop rates ∼2-200 mg/s have been obtained showing good repeatability and uniformity. A calibrated light-emitting diode (LED)-based flowmeter allows measuring and monitoring the drop rate during operation. The fast time-response of the four feeders allows combination of steady and pulsed injections, providing a flexible tool for controlled-dose, real-time impurity injection in fusion plasmas.

  16. 16
    top 1.3%

    Helium line ratio spectroscopy for high spatiotemporal resolution plasma edge profile measurements at ASDEX Upgrade (invited)

    M. Griener, Elisabeth Wolfrum, M. Cavedon, R. Dux, V. Rohde and 5 more

    70 citationsOpen accessdoi:10.1063/1.5034446OpenAlex

    Show abstract

    The thermal helium beam edge diagnostic has recently been upgraded at the ASDEX Upgrade (AUG) tokamak experiment. Line ratio spectroscopy on neutral helium is a valuable tool for simultaneous determination of the electron temperature and density of plasmas. The diagnostic now offers a temporal resolution of 900 kHz with a spatial resolution of up to 3 mm at 32 lines of sight (LOS) simultaneously. The LOS covers a radial region of 8.5 cm, starting at the limiter radius and reaching into the confined region beyond the separatrix. Two components are of particular importance for the aforementioned hardware improvements. The first is the optical head, which collects the light from the experiment. Equipped with an innovative clamping system for optical fiber ends, an arbitrary distribution pattern of LOS can be achieved to gain radial and poloidal profiles. The second major development is a new polychromator system that measures the intensity of the 587 nm, 667 nm, 706 nm, and 728 nm helium lines simultaneously for 32 channels with filter-photomultiplier tube arrays. Thus, the thermal…

  17. 17
    top 1.4%

    A suite-level review of the neutron single-crystal diffraction instruments at Oak Ridge National Laboratory

    Leighton Coates, Huibo B. Cao, Bryan C. Chakoumakos, Matthias Frontzek, Christina M. Hoffmann and 7 more

    69 citationsOpen access (CC-BY)doi:10.1063/1.5030896OpenAlex

    Show abstract

    The nascent suite of single-crystal neutron diffractometers at the Oak Ridge National Laboratory has no equal at any other neutron scattering facility worldwide and offers the potential to re-assert single-crystal diffraction using neutrons as a significant tool to study nuclear and magnetic structures of small unit cell crystals, nuclear structures of macromolecules, and diffuse scattering. Signature applications and features of single-crystal neutron diffraction are high resolution nuclear structure analysis, magnetic structure and spin density determinations, contrast variation (particularly D2O/H2O) for nuclear structural studies, lack of radiation damage when using crystals of biological molecules such as proteins, and the fidelity to measure nuclear and magnetic diffuse scattering with elastic discrimination.

  18. 18
    top 1.4%

    Dynamic mode decomposition for plasma diagnostics and validation

    Roy Taylor, J. Nathan Kutz, Kyle Morgan, Brian A. Nelson

    68 citationsOpen accessdoi:10.1063/1.5027419OpenAlex

    Show abstract

    We demonstrate the application of the Dynamic Mode Decomposition (DMD) for the diagnostic analysis of the nonlinear dynamics of a magnetized plasma in resistive magnetohydrodynamics. The DMD method is an ideal spatio-temporal matrix decomposition that correlates spatial features of computational or experimental data while simultaneously associating the spatial activity with periodic temporal behavior. DMD can produce low-rank, reduced order surrogate models that can be used to reconstruct the state of the system with high fidelity. This allows for a reduction in the computational cost and, at the same time, accurate approximations of the problem, even if the data are sparsely sampled. We demonstrate the use of the method on both numerical and experimental data, showing that it is a successful mathematical architecture for characterizing the helicity injected torus with steady inductive (HIT-SI) magnetohydrodynamics. Importantly, the DMD produces interpretable, dominant mode structures, including a stationary mode consistent with our understanding of a HIT-SI spheromak accompanied by…

  19. 19
    top 1.5%

    Analysis of wall-embedded Langmuir probe signals in different conditions on the Tokamak à Configuration Variable

    O. Février, C. Theiler, H. De Oliveira, B. Labit, N. Fedorczak and 1 more

    66 citationsOpen access (CC-BY-NC-ND)doi:10.1063/1.5022459OpenAlex

    Show abstract

    This paper presents the current wall-embedded Langmuir probe system installed on the Tokamak à Configuration Variable (TCV), as well as the analysis tool chain used to interpret the current-voltage characteristic obtained when the probes are operated in swept-bias conditions. The analysis is based on a four-parameter fit combined with a minimum temperature approach. In order to reduce the effect of plasma fluctuations and measurement noise, several current-voltage characteristics are usually averaged before proceeding to the fitting. The impact of this procedure on the results is investigated, as well as the possible role of finite resistances in the circuitry, which could lead to an overestimation of the temperature. We study the application of the procedure in a specific regime, the plasma detachment, where results from other diagnostics indicate that the electron temperature derived from the Langmuir probes might be overestimated. To address this issue, we explore other fitting models and, in particular, an extension of the asymmetric double probe fit, which features effects of…

  20. 20
    top 1.6%

    A new elliptical-beam method based on time-domain thermoreflectance (TDTR) to measure the in-plane anisotropic thermal conductivity and its comparison with the beam-offset method

    Puqing Jiang, Xin Qian, Ronggui Yang

    65 citationsOpen accessdoi:10.1063/1.5029971OpenAlex

    Show abstract

    Materials lacking in-plane symmetry are ubiquitous in a wide range of applications such as electronics, thermoelectrics, and high-temperature superconductors, in all of which the thermal properties of the materials play a critical part. However, very few experimental techniques can be used to measure in-plane anisotropic thermal conductivity. A beam-offset method based on time-domain thermoreflectance (TDTR) was previously proposed to measure in-plane anisotropic thermal conductivity. However, a detailed analysis of the beam-offset method is still lacking. Our analysis shows that uncertainties can be large if the laser spot size or the modulation frequency is not properly chosen. Here we propose an alternative approach based on TDTR to measure in-plane anisotropic thermal conductivity using a highly elliptical pump (heating) beam. The highly elliptical pump beam induces a quasi-one-dimensional temperature profile on the sample surface that has a fast decay along the short axis of the pump beam. The detected TDTR signal is exclusively sensitive to the in-plane thermal conductivity…

  21. 21
    top 1.7%

    Remote in situ laser-induced breakdown spectroscopic approach for diagnosis of the plasma facing components on experimental advanced superconducting tokamak

    Dongye Zhao, Cong Li, Zhenhua Hu, Chunlei Feng, Qingmei Xiao and 11 more

    65 citationsdoi:10.1063/1.5024848OpenAlex

    Show abstract

    The diagnosis of the fuel retention and impurity deposition on the plasma facing components (PFCs) is very important for monitoring plasma-wall interactions and improving the performance of long-pulse operation for tokamak devices. In this study, a remote in situ laser-induced breakdown spectroscopic (RIS-LIBS) system has been developed to be an effective and routine method for the diagnosis of the composition of the PFCs on Experimental Advanced Superconducting Tokamak (EAST). The RIS-LIBS system can be operated between EAST discharges via a remote network control system. This allows a flexible diagnosis for the PFCs at a specific EAST discharge operation or under planned plasma scenarios according to the experimental requirement. Measurements on the fuel retention and impurity deposition of the PFCs have been performed for the test of the RIS-LIBS system, and the depth resolution and the lateral resolution of the RIS-LIBS system have been achieved to be ∼100 nm and ∼3.0 mm, respectively. For the test of detectable elements, the fuel (deuterium) and impurities have been detected…

  22. 22
    top 1.7%

    Anisotropic thermal conductivity measurement using a new Asymmetric-Beam Time-Domain Thermoreflectance (AB-TDTR) method

    Man Li, Joon Sang Kang, Yongjie Hu

    63 citationsOpen accessdoi:10.1063/1.5026028OpenAlex

    Show abstract

    Anisotropic thermal properties are of both fundamental and practical interests, but remain challenging to characterize using conventional methods. In this work, a new metrology based on asymmetric beam time-domain thermoreflectance (AB-TDTR) is developed to measure three-dimensional anisotropic thermal transport by extending the conventional TDTR technique. Using an elliptical laser beam with controlled elliptical ratio and spot size, the experimental signals can be exploited to be dominantly sensitive to measure thermal conductivity along the cross-plane or any specific in-plane directions. An analytic solution for a multi-layer system is derived for the AB-TDTR signal in response to the periodical pulse, elliptical laser beam, and heating geometry to extract the anisotropic thermal conductivity from experimental measurement. Examples with experimental data are given for various materials with in-plane thermal conductivity from 5 W/m K to 2000 W/m K, including isotropic materials (silicon, boron phosphide, and boron nitride), transversely isotropic materials (graphite, quartz, and…

  23. 23
    top 1.8%

    Thermal characterization of gallium oxide Schottky barrier diodes

    Bikramjit Chatterjee, Asanka Jayawardena, Eric R. Heller, David W. Snyder, Sarit Dhar and 1 more

    62 citationsdoi:10.1063/1.5053621OpenAlex

    Show abstract

    The higher critical electric field of β-gallium oxide (Ga2O3) gives promise to the development of next generation power electronic devices with improved size, weight, power, and efficiency over current state-of-the-art wide bandgap devices based on 4H-silicon carbide (SiC) and gallium nitride (GaN). However, it is expected that Ga2O3 devices will encounter serious thermal issues due to the poor thermal conductivity of the material. In this work, self-heating in Ga2O3 Schottky barrier diodes under different regimes of the diode operation was investigated using diverse optical thermography techniques including thermoreflectance thermal imaging, micro-Raman thermography, and infrared thermal microscopy. 3D coupled electro-thermal modeling was used to validate experimental results and to understand the mechanism of heat generation for the diode structures. Measured top-side and cross-sectional temperature fields suggest that device and circuit engineers should account for the concentrated heat generation that occurs near the anode/Ga2O3 interface and/or the lightly doped drift layer…

  24. 24
    top 1.9%

    Laser frequency stabilization using a commercial wavelength meter

    Luc Couturier, Ingo Nosske, Fachao Hu, Canzhu Tan, Chang Qiao and 3 more

    62 citationsOpen accessdoi:10.1063/1.5025537OpenAlex

    Show abstract

    We present the characterization of a laser frequency stabilization scheme using a state-of-the-art wavelength meter based on solid Fizeau interferometers. For a frequency-doubled Ti-sapphire laser operated at 461 nm, an absolute Allan deviation below 10−9 with a standard deviation of 1 MHz over 10 h is achieved. Using this laser for cooling and trapping of strontium atoms, the wavemeter scheme provides excellent stability in single-channel operation. Multi-channel operation with a multimode fiber switch results in fluctuations of the atomic fluorescence correlated to residual frequency excursions of the laser. The wavemeter-based frequency stabilization scheme can be applied to a wide range of atoms and molecules for laser spectroscopy, cooling, and trapping.

  25. 25
    top 2%

    A simple vibrating sample magnetometer for macroscopic samples

    Víctor López‐Domínguez, Adrián Quesada, Jesús Carlos Guzmán-Mínguez, L. Moreno, Martin Lere and 5 more

    62 citationsOpen accessdoi:10.1063/1.5017708OpenAlex

    Show abstract

    We here present a simple model of a vibrating sample magnetometer (VSM). The system allows recording magnetization curves at room temperature with a resolution of the order of 0.01 emu and is appropriated for macroscopic samples. The setup can be mounted with different configurations depending on the requirements of the sample to be measured (mass, saturation magnetization, saturation field, etc.). We also include here examples of curves obtained with our setup and comparison curves measured with a standard commercial VSM that confirms the reliability of our device.

  26. 26
    top 2%

    Contributed Review: A review of compact interferometers

    J. Watchi, S. J. Cooper, Binlei Ding, Conor M Mow-Lowry, Christophe Collette

    61 citationsOpen accessdoi:10.1063/1.5052042OpenAlex

    Show abstract

    Compact interferometers, called phasemeters, make it possible to operate over a large range while ensuring a high resolution. Such performance is required for the stabilization of large instruments dedicated to experimental physics such as gravitational wave detectors. This paper aims at presenting the working principle of the different types of phasemeters developed in the literature. These devices can be classified into two categories: homodyne and heterodyne interferometers. Improvement of resolution and accuracy has been studied for both devices. Resolution is related to the noise sources that are added to the signal. Accuracy corresponds to distortion of the phase measured with respect to the real phase, called non-linearity. The solutions proposed to improve the device resolution and accuracy are discussed based on a comparison of the reached resolutions and of the residual non-linearities.

  27. 27
    top 2.1%

    Contributed Review: Culet diameter and the achievable pressure of a diamond anvil cell: Implications for the upper pressure limit of a diamond anvil cell

    Earl F. O’Bannon, Zsolt Jenei, Hyunchae Cynn, Magnus J. Lipp, Jason R. Jeffries

    61 citationsOpen accessdoi:10.1063/1.5049720OpenAlex

    Show abstract

    Recently, static pressures of more than 1.0 TPa have been reported, which raises the question: what is the maximum static pressure that can be achieved using diamond anvil cell techniques? Here we compile culet diameters, bevel diameters, bevel angles, and reported pressures from the literature. We fit these data and find an expression that describes the maximum pressure as a function of the culet diameter. An extrapolation of our fit reveals that a culet diameter of 1 μm should achieve a pressure of ∼1.8 TPa. Additionally, for pressure generation of ∼400 GPa with a single beveled diamond anvil, the most commonly reported parameters are a culet diameter of ∼20 μm, a bevel angle of 8.5°, and a bevel diameter to culet diameter ratio between 14 and 18. Our analysis shows that routinely generating pressures more than ∼300 GPa likely requires diamond anvil geometries that are fundamentally different from a beveled or double beveled anvil (e.g., toroidal or double stage anvils) and culet diameters that are ≤20 μm.

  28. 28
    top 2.2%

    OMNY—A tOMography Nano crYo stage

    Mirko Holler, Jörg Raabe, Ana Díaz, Manuel Guizar‐Sicairos, Roger Albert Wepf and 12 more

    61 citationsOpen access (CC-BY)doi:10.1063/1.5020247OpenAlex

    Show abstract

    For many scientific questions gaining three-dimensional insight into a specimen can provide valuable information. We here present an instrument called "tOMography Nano crYo (OMNY)," dedicated to high resolution 3D scanning x-ray microscopy at cryogenic conditions via hard X-ray ptychography. Ptychography is a lens-less imaging method requiring accurate sample positioning. In OMNY, this in achieved via dedicated laser interferometry and closed-loop position control reaching sub-10 nm positioning accuracy. Cryogenic sample conditions are maintained via conductive cooling. 90 K can be reached when using liquid nitrogen as coolant, and 10 K is possible with liquid helium. A cryogenic sample-change mechanism permits measurements of cryogenically fixed specimens. We compare images obtained with OMNY with older measurements performed using a nitrogen gas cryo-jet of stained, epoxy-embedded retina tissue and of frozen-hydrated Chlamydomonas cells.

  29. 29
    top 2.3%

    Invited Review Article: Multi-tip scanning tunneling microscopy: Experimental techniques and data analysis

    Bert Voigtländer, Vasily Cherepanov, Stefan Korte, Arthur Leis, David Cuma and 2 more

    60 citationsOpen accessdoi:10.1063/1.5042346OpenAlex

    Show abstract

    In scanning tunneling microscopy, we witness in recent years a paradigm shift from “just imaging” to detailed spectroscopic measurements at the nanoscale and multi-tip scanning tunneling microscope (STM) is a technique following this trend. It is capable of performing nanoscale charge transport measurements like a “multimeter at the nanoscale.” Distance-dependent four-point measurements, the acquisition of nanoscale potential maps at current carrying nanostructures and surfaces, as well as the acquisition of I − V curves of nanoelectronic devices are examples of the capabilities of the multi-tip STM technique. In this review, we focus on two aspects: How to perform the multi-tip STM measurements and how to analyze the acquired data in order to gain insight into nanoscale charge transport processes for a variety of samples. We further discuss specifics of the electronics for multi-tip STM and the properties of tips for multi-tip STM, and present methods for a tip approach to nanostructures on insulating substrates. We introduce methods on how to extract the conductivity/resistivity…

  30. 30
    top 2.3%

    A scanning tunneling microscope for spectroscopic imaging below 90 mK in magnetic fields up to 17.5 T

    T. Machida, Y. Kohsaka, T. Hanaguri

    60 citationsOpen accessdoi:10.1063/1.5049619OpenAlex

    Show abstract

    We describe the development and performance of an ultra-high vacuum scanning tunneling microscope working under combined extreme conditions of ultra-low temperatures and high magnetic fields. We combined a top-loading dilution refrigerator and a standard bucket dewar with a bottom-loading superconducting magnet to achieve 4.5 days operating time, which is long enough to perform various spectroscopic-imaging measurements. To bring the effective electron temperature closer to the mixing-chamber temperature, we paid particular attention to filtering out radio-frequency noise, as well as enhancing the thermal link between the microscope unit and the mixing chamber. We estimated the lowest effective electron temperature to be below 90 mK by measuring the superconducting-gap spectrum of aluminum. We confirmed the long-term stability of the spectroscopic-imaging measurement by visualizing superconducting vortices in the cuprate superconductor Bi2Sr2CaCu2O8+δ.

  31. 31
    top 2.4%

    Note: Parallel processing algorithm of temperature and noise error for micro-electro-mechanical system gyroscope based on variational mode decomposition and augmented nonlinear differentiator

    Chong Shen, Jiangtao Yang, Jun Tang, Jun Liu, Huiliang Cao

    60 citationsdoi:10.1063/1.5037052OpenAlex

    Show abstract

    The traditional processing model of the temperature error for a gyroscope is serial, meaning that de-noising and temperature drift compensation are implemented in a two-step procedure. Hence, the result of the latter depends on the performance of the former; in particular, negative de-noising produces a negative compensation result. To reduce this dependence, we propose a parallel processing algorithm of the temperature error based on variational mode decomposition (VMD) and an augmented nonlinear differentiator (AND). An application to a micro-electro-mechanical system gyroscope is described to demonstrate the effectiveness and applicability of the proposed algorithm. Its major advantages are (i) a combination of VMD, extreme learning machines, and AND is proposed, and an adaptive accelerometer factor determination method for AND is given based on the VMD, both of which improve the effectiveness of the de-noising process; (ii) temperature drift and noise in the temperature error can be extracted and processed synchronously, thereby reducing the dependency of drift compensation on…

  32. 32
    top 2.5%

    A reaction cell for ambient pressure soft x-ray absorption spectroscopy

    C. Castán-Guerrero, Damjan Krizmancic, Valentina Bonanni, Raju Edla, A. Deluisa and 4 more

    59 citationsOpen accessdoi:10.1063/1.5019333OpenAlex

    Show abstract

    We present a new experimental setup for performing X-ray Absorption Spectroscopy (XAS) in the soft X-ray range at ambient pressure. The ambient pressure XAS setup is fully compatible with the ultra high vacuum environment of a synchrotron radiation spectroscopy beamline end station by means of ultrathin Si3N4 membranes acting as windows for the X-ray beam and seal of the atmospheric sample environment. The XAS detection is performed in total electron yield (TEY) mode by probing the drain current from the sample with a picoammeter. The high signal/noise ratio achievable in the TEY mode, combined with a continuous scanning of the X-ray energies, makes it possible recording XAS spectra in a few seconds. The first results show the performance of this setup to record fast XAS spectra from sample surfaces exposed at atmospheric pressure, even in the case of highly insulating samples. The use of a permanent magnet inside the reaction cell enables the measurement of X-ray magnetic circular dichroism at ambient pressure.

  33. 33
    top 2.6%

    Simultaneous measurement of surface tension and viscosity using freely decaying oscillations of acoustically levitated droplets

    J. Kremer, Andreas Kilzer, Marcus Petermann

    58 citationsdoi:10.1063/1.4998796OpenAlex

    Show abstract

    Oscillations of small liquid drops around a spherical shape have been of great interest to scientists measuring physical properties such as interfacial tension and viscosity, over the last few decades. A powerful tool for contactless positioning is acoustic levitation, which has been used to simultaneously determine the surface tension and viscosity of liquids at ambient pressure. In order to extend this acoustic levitation measurement method to high pressure systems, the method is first evaluated under ambient pressure. To measure surface tension and viscosity using acoustically levitated oscillating drops, an image analysis method has to be developed and factors which may affect measurement, such as sound field or oscillation amplitude, have to be analyzed. In this paper, we describe the simultaneous measurement of surface tension and viscosity using freely decaying shape oscillations of acoustically levitated droplets of different liquids (silicone oils AK 5 and AK 10, squalane, 1-propanol, 1-butanol, 1-pentanol, 1-hexanol, 1-heptanol, and 1-octanol) in air. These liquids vary in…

  34. 34
    top 2.7%

    Calibration and cross-laboratory implementation of scintillating screens for electron bunch charge determination

    Thomas Kurz, Jurjen Couperus Cabadağ, Jakob Matthias Krämer, Hao Ding, Stephan Kuschel and 10 more

    57 citationsOpen accessdoi:10.1063/1.5041755OpenAlex

    Show abstract

    We revise the calibration of scintillating screens commonly used to detect relativistic electron beams with low average current, e.g., from laser-plasma accelerators, based on new and expanded measurements that include higher charge density and different types of screens than previous work [Buck et al., Rev. Sci. Instrum. 81, 033301 (2010)]. Electron peak charge densities up to 10 nC/mm2 were provided by focused picosecond-long electron beams delivered by the Electron Linac for beams with high Brilliance and low Emittance (ELBE) at the Helmholtz-Zentrum Dresden-Rossendorf. At low charge densities, a linear scintillation response was found, followed by the onset of saturation in the range of nC/mm2. The absolute calibration factor (photons/sr/pC) in this linear regime was measured to be almost a factor of 2 lower than that reported by Buck et al. retrospectively implying a higher charge in the charge measurements performed with the former calibration. A good agreement was found with the results provided by Glinec et al. [Rev. Sci. Instrum. 77, 103301 (2006)]. Furthermore long-term…

  35. 35
    top 2.7%

    An enhanced Bouc-Wen model for characterizing rate-dependent hysteresis of piezoelectric actuators

    Jinqiang Gan, Xianmin Zhang

    56 citationsdoi:10.1063/1.5038591OpenAlex

    Show abstract

    A classical Bouc-Wen model is widely applied in hysteresis modeling and compensation for piezoelectric ceramic actuators. However, the classical Bouc-Wen model cannot characterize rate-dependent hysteresis under excitations at high frequencies precisely. In this paper, an enhanced Bouc-Wen model is developed by introducing the frequency of input voltage based on the classical Bouc-Wen model. A number of experiments were conducted to characterize the rate-dependent hysteresis of piezoelectric ceramic actuators under sinusoidal excitations at a range of 1–150 Hz. The measured data were used to demonstrate the validity of the developed model. A method of parameter estimation based on the Matlab/Simulink parameter estimation tool is adopted to identify the parameters of models. The comparisons of experiments and simulations show that the developed model can describe rate-dependent hysteresis more accurately than the classical Bouc-Wen model. The modeling errors of the developed model were decreased by nearly 75% compared with that of the classical Bouc-Wen model. The root-mean-square…

  36. 36
    top 2.8%

    An open and flexible digital phase-locked loop for optical metrology

    Alex Tourigny-Plante, Vincent Michaud-Belleau, Nicolas Bourbeau Hébert, Hugo Bergeron, Jérôme Genest and 1 more

    56 citationsOpen accessdoi:10.1063/1.5039344OpenAlex

    Show abstract

    This paper presents an open and flexible digital phase-locked loop optimized for laser stabilization systems. It is implemented on a cheap and easily accessible FPGA-based digital electronics platform (Red Pitaya) running a customizable open-source firmware. A PC-based software interface allows controlling the platform and optimizing the loop parameters remotely. Several tools are included to allow measurement of quantities of interest smoothly and rapidly. To demonstrate the platform's capabilities, we built a fiber noise canceller over a 400 m fiber link. Noise cancellation was achieved over a 30 kHz bandwidth, a value limited mainly by the delays introduced by the actuator and by the round-trip propagation over the fiber link. We measured a total latency of 565 ns for the platform itself, limiting the theoretically achievable control bandwidth to approximately 225 kHz.

  37. 37
    top 2.9%

    Fabrication of a precise ellipsoidal mirror for soft X-ray nanofocusing

    Hidekazu Mimura, Yoshinori Takei, Takehiro Kume, Yoko Takeo, Hiroto Motoyama and 6 more

    56 citationsdoi:10.1063/1.5035323OpenAlex

    Show abstract

    In X-ray focusing, grazing incidence mirrors offer advantages of no chromatic aberration and high focusing efficiency. Although nanofocusing mirrors have been developed for the hard X-ray region, there is no mirror with nanofocusing performance in the soft X-ray region. Designing a system with the ability to focus to a beam size smaller than 100 nm at an X-ray energy of less than 1 keV requires a numerical aperture larger than 0.01. This leads to difficulties in the fabrication of a soft X-ray focusing mirror with high accuracy. Ellipsoidal mirrors enable soft X-ray focusing with a high numerical aperture. In this study, we report a production process for ellipsoidal mirrors involving mandrel fabrication and replication processes. The fabricated ellipsoidal mirror was assessed under partial illumination conditions at the soft X-ray beamline (BL25SU) of SPring-8. A focal spot size of less than 250 nm was confirmed at 300 eV. The focusing tests indicated that the proposed fabrication process is promising for X-ray mirrors that have the form of a solid of revolution, including Wolter…

  38. 38
    top 3%

    Development of a hard X-ray split-and-delay line and performance simulations for two-color pump-probe experiments at the European XFEL

    W. Lu, Bertram Friedrich, Tino Noll, Kaishang Zhou, Jörg Hallmann and 6 more

    55 citationsOpen accessdoi:10.1063/1.5027071OpenAlex

    Show abstract

    A hard X-ray Split-and-Delay Line (SDL) under construction for the Materials Imaging and Dynamics station at the European X-Ray Free-Electron Laser (XFEL) is presented. This device aims at providing pairs of X-ray pulses with a variable time delay ranging from −10 ps to 800 ps in a photon energy range from 5 to 10 keV for photon correlation and X-ray pump-probe experiments. A custom designed mechanical motion system including active feedback control ensures that the high demands for stability and accuracy can be met and the design goals achieved. Using special radiation configurations of the European XFEL’s SASE-2 undulator (SASE: Self-Amplified Spontaneous Emission), two-color hard x-ray pump-probe schemes with varying photon energy separations have been proposed. Simulations indicate that more than 109 photons on the sample per pulse-pair and up to about 10% photon energy separation can be achieved in the hard X-ray region using the SDL.

  39. 39
    top 3%

    A laboratory spectrometer for high throughput X-ray emission spectroscopy in catalysis research

    Wolfgang Malzer, Daniel Grötzsch, Richard Gnewkow, Christopher Schlesiger, Fabian Kowalewski and 3 more

    54 citationsOpen access (CC-BY)doi:10.1063/1.5035171OpenAlex

    Show abstract

    We have built a laboratory spectrometer for X-ray emission spectroscopy. The instrument is employed in catalysis research. The key component is a von Hamos full cylinder optic with Highly Annealed Pyrolytic Graphite (HAPG) as a dispersive element. With this very efficient optic, the spectrometer subtends an effective solid angle of detection of around 1 msr, allowing for the analysis of dilute samples. The resolving power of the spectrometer is approximately E/ΔE = 4000, with an energy range of ∼2.3 keV-10 keV. The instrument and its characteristics are described herein. Further, a comparison with a prototype spectrometer, based on the same principle, shows the substantial improvement in the spectral resolution and energy range for the present setup. The paper concludes with a discussion of sample handling. A compilation of HAPG fundamentals and related publications are given in a brief Appendix.

  40. 40
    top 3.1%

    A novel trigger for pseudospark switch with high repetition rate, low jitter, and compact structure

    Jiaqi Yan, Saikang Shen, Yanan Wang, Siyu Zhang, Le Cheng and 1 more

    54 citationsdoi:10.1063/1.5029420OpenAlex

    Show abstract

    This paper presents the design and development of a trigger with a high repetition rate, low jitter, and compact structure for the pseudospark switch (PSS), which includes an improved Marx generator based on avalanche transistors and a corona-plasma trigger unit. The generator adopted a novel 3 × 12-stage Marx circuit based on avalanche transistors in which the failure rate of transistors in the first and second stages was significantly reduced by connecting the parallel capacitors compared to the previous similar generator. The reason for the improved performance was also discussed. The main parameters of output pulses were an amplitude of −7 kV, rise time of 6 ns, jitter of 0.2 ns, and repetition rate of 2 kHz. The corona-plasma trigger unit adopted BaTiO3 ceramics with high εr as the dielectric and was arranged in the hollow cathode of the PSS. The experiments of triggering a PSS prototype were conducted. The influence of anode voltage and pressure on the trigger delay and jitter was studied, and the minimum trigger jitter achieved <1 ns. This trigger worked for 107 shots at the…

  41. 41
    top 3.2%

    Laser driving and data processing concept for mobile trace gas sensing: Design and implementation

    Chang Liu, Béla Tuzson, Philipp Scheidegger, Herbert Looser, Bernhard Bereiter and 5 more

    54 citationsOpen access (OTHER-OA)doi:10.1063/1.5026546OpenAlex

    Show abstract

    High precision mobile sensing of multi-species gases is greatly demanded in a wide range of applications. Although quantum cascade laser absorption spectroscopy demonstrates excellent field-deployment capabilities for gas sensing, the implementation of this measurement technique into sensor-like portable instrumentation still remains challenging. In this paper, two crucial elements, the laser driving and data acquisition electronics, are addressed. Therefore, we exploit the benefits of the time-division multiplexed intermittent continuous wave driving concept and the real-time signal pre-processing capabilities of a commercial System-on-Chip (SoC, Red Pitaya). We describe a re-designed current driver that offers a universal solution for operating a wide range of multi-wavelength quantum cascade laser device types and allows stacking for the purpose of multiple laser configurations. Its adaptation to the various driving situations is enabled by numerous field programmable gate array (FPGA) functionalities that were developed on the SoC, such as flexible generation of a large variety…

  42. 42
    top 3.3%

    Invited Review Article: Photofragment imaging

    Arthur G. Suits

    51 citationsdoi:10.1063/1.5045325OpenAlex

    Show abstract

    Photodissociation studies in molecular beams that employ position-sensitive particle detection to map product recoil velocities emerged thirty years ago and continue to evolve with new laser and detector technologies. These powerful methods allow application of tunable laser detection of single product quantum states, simultaneous measurement of velocity and angular momentum polarization, measurement of joint product state distributions for the detected and undetected products, coincident detection of multiple product channels, and application to radicals and ions as well as closed-shell molecules. These studies have permitted deep investigation of photochemical dynamics for a broad range of systems, revealed new reaction mechanisms, and addressed problems of practical importance in atmospheric, combustion, and interstellar chemistry. This review presents an historical overview, a detailed technical account of the range of methods employed, and selected experimental highlights illustrating the capabilities of the method.

  43. 43
    top 3.3%

    Active spectroscopy measurements of the deuterium temperature, rotation, and density from the core to scrape off layer on the DIII-D tokamak (invited)

    S. R. Haskey, B. A. Grierson, L. Stagner, C. Chrystal, Arash Ashourvan and 7 more

    51 citationsOpen accessdoi:10.1063/1.5038349OpenAlex

    Show abstract

    Main-ion charge exchange recombination spectroscopy (MICER) uses the neutral beam induced Dα spectrum to measure the local deuterium ion (D+) temperature, rotation, and density, as well as parameters related to the neutral beams, fast ions, and magnetic field. An edge MICER system consisting of 16 densely packed chords was recently installed on DIII-D, extending the MICER technique from the core to the pedestal and steep gradient region of H-mode plasmas where the D+ and commonly measured impurity ion properties can differ significantly. A combination of iterative collisional radiative modeling techniques and greatly accelerated spectral fitting allowed the extension of this diagnostic technique to the plasma edge where the steep gradients introduce significant diagnostic challenges. The importance of including the fast ion Dα emission in the fit to the spectrum for the edge system is investigated showing that it is typically not important except for cases which can have significant fast ion fractions near the plasma edge such as QH-mode. Example profiles from an Ohmic L-mode and a…

  44. 44
    top 3.4%

    Swarm intelligence-based approach for optimal design of CMOS differential amplifier and comparator circuit using a hybrid salp swarm algorithm

    A. Sasikumar, R. Muthaiah

    51 citationsdoi:10.1063/1.5020999OpenAlex

    Show abstract

    In this paper, an automatic design method based on a swarm intelligence approach for CMOS analog integrated circuit (IC) design is presented. The hybrid meta-heuristics optimization technique, namely, the salp swarm algorithm (SSA), is applied to the optimal sizing of a CMOS differential amplifier and the comparator circuit. SSA is a nature-inspired optimization algorithm which mimics the navigating and hunting behavior of salp. The hybrid SSA is applied to optimize the circuit design parameters and to minimize the MOS transistor sizes. The proposed swarm intelligence approach was successfully implemented for an automatic design and optimization of CMOS analog ICs using Generic Process Design Kit (GPDK) 180 nm technology. The circuit design parameters and design specifications are validated through a simulation program for integrated circuit emphasis simulator. To investigate the efficiency of the proposed approach, comparisons have been carried out with other simulation-based circuit design methods. The performances of hybrid SSA based CMOS analog IC designs are better than the…

  45. 45
    top 3.5%

    Detailed precision and accuracy analysis of swarm parameters from a pulsed Townsend experiment

    Pascal Haefliger, Christian Michael Franck

    48 citationsOpen access (OTHER-OA)doi:10.1063/1.5002762OpenAlex

    Show abstract

    A newly built pulsed Townsend experimental setup which allows one to measure both electron and ion currents is presented. The principle of pulsed Townsend measurements itself is well established to obtain swarm parameters such as the effective ionization rate coefficient, the density-reduced mobility, and the density-normalized longitudinal diffusion coefficient. The main novelty of the present contribution is a detailed and comprehensive analysis of the entire measurement and evaluation chain with respect to accuracy, precision, and reproducibility. The influence of the input parameters (gap distance, applied voltage, measured pressure, and temperature) is analyzed in detail. An overall accuracy of ±0.5% in the density reduced electric field (E/N) is achieved, which is close to the theoretically possible limit using the chosen components. The precision of the experimental results is higher than the accuracy. Through an extensive measurement campaign, the repeatability of our measurements proved to be high and similar to the precision. The reproducibility of results at identical…

  46. 46
    top 3.6%

    A highly stable monolithic enhancement cavity for second harmonic generation in the ultraviolet

    Stephan Hannig, J. Mielke, Julia-Aileen Fenske, Mattias Misera, Nikolai Beev and 2 more

    48 citationsOpen access (CC-BY)doi:10.1063/1.5005515OpenAlex

    Show abstract

    We present a highly stable bow-tie power enhancement cavity for critical second harmonic generation (SHG) into the UV using a Brewster-cut β-BaB2O4 (BBO) nonlinear crystal. The cavity geometry is suitable for all UV wavelengths reachable with BBO and can be modified to accommodate anti-reflection coated crystals, extending its applicability to the entire wavelength range accessible with non-linear frequency conversion. The cavity is length-stabilized using a fast general purpose digital PI controller based on the open source STEMlab 125-14 (formerly Red Pitaya) system acting on a mirror mounted on a fast piezo actuator. We observe 130 h uninterrupted operation without decay in output power at 313 nm. The robustness of the system has been confirmed by exposing it to accelerations of up to 1 g with less than 10% in-lock output power variations. Furthermore, the cavity can withstand 30 min of acceleration exposure at a level of 3 grms without substantial change in the SHG output power, demonstrating that the design is suitable for transportable setups.

  47. 47
    top 3.6%

    Description of complex viewing geometries of fusion tomography diagnostics by ray-tracing

    M. Carr, A. Meakins, M. Bernert, P. David, C. Giroud and 6 more

    47 citationsOpen accessdoi:10.1063/1.5031087OpenAlex

    Show abstract

    Ray-tracing techniques are applied to bolometry, a diagnostic where the finite collection volume is particularly sensitive to the machine and detector configuration. A technique is presented that can handle arbitrarily complex aperture and collimator geometries, neglecting reflection effects. Sight lines from the ASDEX Upgrade bolometer foils were ray-traced with a path tracing algorithm, where the optical path is represented by a statistical bundle of ray paths connecting the foil surface with the slit geometry. By using the full 3D machine model for the detector box and first wall, effects such as occlusion and vignetting were included in the calculation of the bolometer's étendue. Inversion matrices calculated with the ray-tracing technique were compared with the more conventional single-ray approach and shown to be naturally more constrained, requiring less regularisation. The two models were tested on a sample radiation scenario, and the common single-ray approximation is shown to be insufficient. These results are particularly relevant for the divertor where strong emission…

  48. 48
    top 3.7%

    A suspended 3-omega technique to measure the anisotropic thermal conductivity of semiconducting polymers

    Sampath Kommandur, Shannon K. Yee

    46 citationsdoi:10.1063/1.5045077OpenAlex

    Show abstract

    Anisotropic thermal conductivity can complicate the performance of semiconducting polymer thin-films in applications such as thermoelectrics and photovoltaics. Anisotropic measurements of low thermal conductivity polymers are challenging, and there are a limited number of appropriate measurement techniques. Suspended film 3-omega is an appropriate technique but has often required unfavorable microfabrication. Herein, we report on the utility of the suspended 3-omega technique that uses shadow masking, and no other microfabrication techniques, in performing anisotropic (in-plane and through-plane) thermal conductivity measurements of polymer films. We report on the necessary conditions for the validity of the 1D suspended-film heat transfer model and provide experimental guidelines for in-plane thermal conductivity measurements of polymer thin-films. Furthermore, for the first time, we report the anisotropic thermal conductivities of N2200 and a low molecular weight P3HT, which are two common n-type and p-type semiconducting polymers. Measured thermal conductivities are compared with…

  49. 49
    top 3.8%

    Broadband longwave radio remote sensing instrumentation

    Morris B. Cohen, Ryan K. Said, Evans W. Paschal, Jackson C. McCormick, N. C. Gross and 4 more

    46 citationsOpen accessdoi:10.1063/1.5041419OpenAlex

    Show abstract

    We present the performance characteristics of a high-sensitivity radio receiver for the frequency band 0.5-470 kHz, known as the Low Frequency Atmospheric Weather Electromagnetic System for Observation, Modeling, and Education, or LF AWESOME. The receiver is an upgraded version of the VLF AWESOME, completed in 2004, which provided high sensitivity broadband radio measurements of natural lightning emissions, transmitting beacons, and radio emissions from the near-Earth space environment. It has been deployed at many locations worldwide and used as the basis for dozens of scientific studies. We present here a significant upgrade to the AWESOME, in which the frequency range has been extended to include the LF and part of the medium frequency (MF) bands, the sensitivity improved by 10-25 dB to be as low as 0.03 fT/Hz, depending on the frequency, and timing error reduced to 15-20 ns range. The expanded capabilities allow detection of radio atmospherics from lightning strokes at global distances and multiple traverses around the world. It also allows monitoring of transmitting beacons in…

  50. 50
    top 3.9%

    Observations of core ion cyclotron emission on ASDEX Upgrade tokamak

    Roman Ochoukov, Volodymyr Bobkov, B. Chapman, Richard O. Dendy, M. Dunne and 13 more

    46 citationsOpen accessdoi:10.1063/1.5035180OpenAlex

    Show abstract

    The B-dot probe diagnostic suite on the ASDEX Upgrade tokamak has recently been upgraded with a new 125 MHz, 14 bit resolution digitizer to study ion cyclotron emission (ICE). While classic edge emission from the low field side plasma is often observed, we also measure waves originating from the core with fast fusion protons or beam injected deuterons being a possible emission driver. Comparing the measured frequency values with ion cyclotron harmonics present in the plasma places the origin of this emission on the magnetic axis, with the fundamental hydrogen/second deuterium cyclotron harmonic matching the observed values. The actual values range from ∼27 MHz at the on-axis toroidal field BT = −1.79 T to ∼40 MHz at BT = −2.62 T. When the magnetic axis position evolves during this emission, the measured frequency values track the changes in the estimated on-axis cyclotron frequency values. Core ICE is usually a transient event lasting ∼100 ms during the neutral beam startup phase. However, in some cases, core emission occurs in steady-state plasmas and lasts for longer than 1 s.…

How to read this list

The cohort is every article, review and book chapter OpenAlex attributes to Review of Scientific Instruments with publication year 2018, excluding retracted works and paratext such as editorials and errata. The top 50 by citation count are listed; the percentile is the rank divided by the cohort size. 50 of the 50 entries have an abstract in OpenAlex. Counts were read on 29 October 2026 and will not be updated on this page, so a quoted rank stays verifiable. Full rules on the methodology page.

Other journals, same idea

Work with these 25 papers in Kahubi

  • The papers land in your library with their DOIs
  • Ask anything across all of them, with citations
  • Draft a literature review from the same sources

Free plan, no card. Your files stay private unless you share them.

Reading several of these?

Kahubi reads papers with you, keeps every citation traceable and drafts with sources you can check. Free plan, no card.