Most-cited articles · 2019
The 50 most-cited articles in Review of Scientific Instruments, 2019
Ranked by OpenAlex citation count on 29 October 2026, out of 995 eligible articles Review of Scientific Instruments published in 2019. Ranks are frozen; this page will not change. Number one, with 358 citations: The qPlus sensor, a powerful core for the atomic force microscope.
- Cohort
- 995 articles
- Listed
- Top 50 (5.0%)
- Open access
- 38 of 50
- Snapshot
- 2026-10-29
The most-cited articles from Review of Scientific Instruments in 2019 are led by instrumentation and methods for microscopy, spectroscopy, and materials characterization. The top paper is “The qPlus sensor, a powerful core for the atomic force microscope” by Franz J. Gießibl, with 358 citations. Other highly cited works describe diffuse optical tomography for brain imaging, thermoreflectance measurement of thermal conductivity, numerical Abel transform methods, and standardized burners for nanoparticle synthesis.
Readers can use this list to identify the instruments, techniques, and review articles that drew the most citations among the 995 eligible articles. The ranking reflects citation counts from OpenAlex and covers topics such as x-ray spectroscopy, photoemission, neutron diffraction, plasma imaging, and high-pressure studies.
Introduction written from the titles and abstracts on this list. Every figure below is the source.
Ask about these papers
Grounded in this list only, with sources.
- 1top 0.2%
The qPlus sensor, a powerful core for the atomic force microscope
Franz J. Gießibl
358 citationsOpen access (CC-BY)doi:10.1063/1.5052264OpenAlex
Show abstractHide abstract
Atomic force microscopy (AFM) was introduced in 1986 and has since made its way into surface science, nanoscience, chemistry, biology, and material science as an imaging and manipulating tool with a rising number of applications. AFM can be employed in ambient and liquid environments as well as in vacuum and at low and ultralow temperatures. The technique is an offspring of scanning tunneling microscopy (STM), where the tunneling tip of the STM is replaced by using a force sensor with an attached tip. Measuring the tiny chemical forces that act between the tip and the sample is more difficult than measuring the tunneling current in STM. Therefore, even 30 years after the introduction of AFM, progress in instrumentation is substantial. Here, we focus on the core of the AFM, the force sensor with its tip and detection mechanism. Initially, force sensors were mainly micro-machined silicon cantilevers, mainly using optical methods to detect their deflection. The qPlus sensor, originally based on a quartz tuning fork and now custom built from quartz, is self-sensing by utilizing the…
- 2top 0.3%
High-density diffuse optical tomography for imaging human brain function
Muriah D. Wheelock, Joseph P. Culver, Adam T. Eggebrecht
169 citationsOpen access (CC-BY)doi:10.1063/1.5086809OpenAlex
Show abstractHide abstract
This review describes the unique opportunities and challenges for noninvasive optical mapping of human brain function. Diffuse optical methods offer safe, portable, and radiation free alternatives to traditional technologies like positron emission tomography or functional magnetic resonance imaging (fMRI). Recent developments in high-density diffuse optical tomography (HD-DOT) have demonstrated capabilities for mapping human cortical brain function over an extended field of view with image quality approaching that of fMRI. In this review, we cover fundamental principles of the diffusion of near infrared light in biological tissue. We discuss the challenges involved in the HD-DOT system design and implementation that must be overcome to acquire the signal-to-noise necessary to measure and locate brain function at the depth of the cortex. We discuss strategies for validation of the sensitivity, specificity, and reliability of HD-DOT acquired maps of cortical brain function. We then provide a brief overview of some clinical applications of HD-DOT. Though diffuse optical measurements of…
- 3top 0.4%
A steady-state thermoreflectance method to measure thermal conductivity
Jeffrey L. Braun, DAVID H. L. OLSON, John T. Gaskins, Patrick E. Hopkins
160 citationsOpen access (CC-BY)doi:10.1063/1.5056182OpenAlex
Show abstractHide abstract
We demonstrate a steady-state thermoreflectance-based optical pump-probe technique to measure the thermal conductivity of materials using a continuous wave laser heat source. The technique works in principle by inducing a steady-state temperature rise in a material via long enough exposure to heating from a pump laser. A probe beam is then used to detect the resulting change in reflectance, which is proportional to the change in temperature at the sample surface. Increasing the power of the pump beam to induce larger temperature rises, Fourier’s law is used to determine the thermal conductivity. We show that this technique is capable of measuring the thermal conductivity of a wide array of materials having thermal conductivities ranging from 1 to >2000 W m−1 K−1, in excellent agreement with literature values.
- 4top 0.5%
A direct comparison of high-speed methods for the numerical Abel transform
Daniel D. Hickstein, Stephen T. Gibson, Roman Yurchak, Dhrubajyoti D. Das, Mikhail Ryazanov
141 citationsOpen accessdoi:10.1063/1.5092635OpenAlex
Show abstractHide abstract
The Abel transform is a mathematical operation that transforms a cylindrically symmetric three-dimensional (3D) object into its two-dimensional (2D) projection. The inverse Abel transform reconstructs the 3D object from the 2D projection. Abel transforms have wide application across numerous fields of science, especially chemical physics, astronomy, and the study of laser-plasma plumes. Consequently, many numerical methods for the Abel transform have been developed, which makes it challenging to select the ideal method for a specific application. In this work, eight published transform methods have been incorporated into a single, open-source Python software package (PyAbel) to provide a direct comparison of the capabilities, advantages, and relative computational efficiency of each transform method. Most of the tested methods provide similar, high-quality results. However, the computational efficiency varies across several orders of magnitude. By optimizing the algorithms, we find that some transform methods are sufficiently fast to transform 1-megapixel images at more than 100…
- 5top 0.6%
SpraySyn—A standardized burner configuration for nanoparticle synthesis in spray flames
F. Schneider, Samer Suleiman, Jan Menser, E. Borukhovich, Irenäus Wlokas and 3 more
139 citationsOpen access (CC-BY)doi:10.1063/1.5090232OpenAlex
Show abstractHide abstract
In many scientific communities, the definition of standardized experiments has enabled major progress in process understanding. The investigation of the spray-flame synthesis of nanoparticles at a well-defined standard burner by experiment and simulation makes it possible to produce a comprehensive data set with various established and novel measuring methods. In this work, we introduce the design of the SpraySyn burner as a new standard for a free-jet type burner that offers well-defined and simulation-friendly boundary conditions and geometries as well as accessibility for optical diagnostics. A combustible precursor solution is fed through a centrally located capillary and aerosolized with an oxygen dispersion gas flow. The spray flame is stabilized by a premixed flat methane/oxygen pilot flame fed via a porous bronze matrix surrounded by a stabilizing nitrogen coflow emanating through the same porous matrix, providing easy-to-calculate boundary conditions for simulations. This burner design enables the use of a wide choice of solvents, precursors, and precursor combinations.…
- 6top 0.7%
An improved laboratory-based x-ray absorption fine structure and x-ray emission spectrometer for analytical applications in materials chemistry research
Evan P. Jahrman, William M. Holden, Alexander S. Ditter, Devon R. Mortensen, Gerald T. Seidler and 6 more
119 citationsOpen accessdoi:10.1063/1.5049383OpenAlex
Show abstractHide abstract
X-ray absorption fine structure (XAFS) and x-ray emission spectroscopy (XES) are advanced x-ray spectroscopies that impact a wide range of disciplines. However, unlike the majority of other spectroscopic methods, XAFS and XES are accompanied by an unusual access model, wherein the dominant use of the technique is for premier research studies at world-class facilities, i.e., synchrotron x-ray light sources. In this paper, we report the design and performance of an improved XAFS and XES spectrometer based on the general conceptual design of Seidler et al. [Rev. Sci. Instrum. 85, 113906 (2014)]. New developments include reduced mechanical degrees of freedom, much-increased flux, and a wider Bragg angle range to enable extended x-ray absorption fine structure (EXAFS) measurement and analysis for the first time with this type of modern laboratory XAFS configuration. This instrument enables a new class of routine applications that are incompatible with the mission and access model of the synchrotron light sources. To illustrate this, we provide numerous examples of x-ray absorption near…
- 7top 0.8%
A high-pressure x-ray photoelectron spectroscopy instrument for studies of industrially relevant catalytic reactions at pressures of several bars
Peter Amann, David Degerman, Ming‐Tao Lee, John Alexander, Mikhail Shipilin and 16 more
115 citationsOpen accessdoi:10.1063/1.5109321OpenAlex
Show abstractHide abstract
We present a new high-pressure x-ray photoelectron spectroscopy system dedicated to probing catalytic reactions under realistic conditions at pressures of multiple bars. The instrument builds around the novel concept of a “virtual cell” in which a gas flow onto the sample surface creates a localized high-pressure pillow. This allows the instrument to be operated with a low pressure of a few millibar in the main chamber, while simultaneously a local pressure exceeding 1 bar can be supplied at the sample surface. Synchrotron based hard x-ray excitation is used to increase the electron mean free path in the gas region between sample and analyzer while grazing incidence <5° close to total external refection conditions enhances surface sensitivity. The aperture separating the high-pressure region from the differential pumping of the electron spectrometer consists of multiple, evenly spaced, micrometer sized holes matching the footprint of the x-ray beam on the sample. The resulting signal is highly dependent on the sample-to-aperture distance because photoemitted electrons are subject to…
- 8top 0.9%
A microfocus x-ray computed tomography based gas hydrate triaxial testing apparatus
Yanghui Li, Peng Wu, Weiguo Liu, Xiang Sun, Zhi Wei Cui and 1 more
111 citationsdoi:10.1063/1.5095812OpenAlex
Show abstractHide abstract
Gas hydrate-bearing sediment shows complex mechanical characteristics. Its macroscopic deformation process involves many microstructural changes such as phase transformation, grain transport, and cementation failure. However, the conventional gas hydrate triaxial testing apparatus is not possible to obtain the microstructure in the samples. In this study, a novel, low-temperature (-35 to 20 °C), high-pressure (>16 MPa confining pressure and >95.4 MPa vertical stress) triaxial testing apparatus suitable for X-ray computed tomography scanning is developed. The new apparatus permits time-lapse imaging to capture the role of hydrate saturation, effective stress, strain rate, hydrate decomposition on hydrate-bearing sediment characteristic, and cementation failure behavior. The apparatus capabilities are demonstrated using in situ generation of hydrate on a xenon hydrate-bearing glass bead sample. In the mentioned case, a consolidated drained shear test was conducted, and the imaging reveals hydrate occurrence with a saturation of 37.3% as well as the evolution of localized strain (or…
- 9top 1%
Deducing rotational quantum-state distributions from overlapping molecular spectra
Jan Voráč, Lukáš Kusýn, Petr Synek
108 citationsOpen access (CC-BY)doi:10.1063/1.5128455OpenAlex
Show abstractHide abstract
A novel method for fast and robust calculation of Boltzmann plots from molecular spectra is presented. Its use is demonstrated on the OH(A-X) spectrum near 310 nm. A limitation of the method is identified: for overlapping spectra of the OH(A-X) and N2(C-B, Δv = 1) band sequence, the calculation may often fail due to insufficient number of measured points. This is solved by introducing experimentally determined bounds for the N2(C) rotational distribution. Three cases are presented: (i) with undisturbed OH(A-X) emission, (ii) with strong emission of N2(C-B) in the said spectral range, and (iii) with weak but not negligible nitrogen emission. In case (ii), the data in the spectral range 306–320 nm are sufficient for the analysis. In case (iii), information from another spectral range with undisturbed N2(C-B) emission is necessary. These illustrate all relevant cases often encountered in laboratory plasmas. The calculated Boltzmann plots are not further analyzed in this article but can be used for development and validation of kinetic models with rotational resolution. The…
- 10top 1.1%
Time- and angle-resolved photoemission spectroscopy of solids in the extreme ultraviolet at 500 kHz repetition rate
M. Puppin, Y. Deng, C. W. Nicholson, Johannes Feldl, N. B. M. Schröter and 6 more
104 citationsOpen accessdoi:10.1063/1.5081938OpenAlex
Show abstractHide abstract
Time- and angle-resolved photoemission spectroscopy (trARPES) employing a 500 kHz extreme-ultraviolet light source operating at 21.7 eV probe photon energy is reported. Based on a high-power ytterbium laser, optical parametric chirped pulse amplification, and ultraviolet-driven high-harmonic generation, the light source produces an isolated high-harmonic with 110 meV bandwidth and a flux of more than 1011 photons/s on the sample. Combined with a state-of-the-art ARPES chamber, this table-top experiment allows high-repetition rate pump-probe experiments of electron dynamics in occupied and normally unoccupied (excited) states in the entire Brillouin zone and with a temporal system response function below 40 fs.
- 11top 1.2%
Resonant ultrasound spectroscopy: The essential toolbox
Fedor Balakirev, Susan M. Ennaceur, Robert J. Migliori, Boris Maiorov, A. Migliori
95 citationsOpen access (CC-BY)doi:10.1063/1.5123165OpenAlex
Show abstractHide abstract
Resonant Ultrasound Spectroscopy (RUS) is an ultrasound-based minimal-effort high-accuracy elastic modulus measurement technique. RUS as described here uses the mechanical resonances (normal modes of vibration or just modes) of rectangular parallelepiped or cylindrical specimens with a dimension of from a fraction of a millimeter to as large as will fit into the apparatus. Provided here is all that is needed so that the reader can construct and use a state-of-the-art RUS system. Included are links to open-source circuit diagrams, links to download Los Alamos National Laboratory open-source data acquisition software, links to request free analysis software, procedures for acquiring measurements, considerations on building transducers, 3-D printed stage designs, and a full mathematical explanation of how the analysis software extracts elastic moduli from resonances.
- 12top 1.3%
6 Gbps real-time optical quantum random number generator based on vacuum fluctuation
Ziyong Zheng, Yichen Zhang, Weinan Huang, Song Yu, Hong Mei Guo
95 citationsOpen accessdoi:10.1063/1.5078547OpenAlex
Show abstractHide abstract
We demonstrate a 6 Gbps real-time optical quantum random number generator by measuring vacuum fluctuation. To address the common problem that speed gap exists between fast randomness generation and slow randomness extraction in most high-speed real-time quantum random number generator systems, we present an optimized extraction algorithm based on parallel implementation of Toeplitz hashing to reduce the influence of classical noise due to the imperfection of devices. Notably, the real-time rate of randomness extraction we have achieved reaches the highest speed of 12 Gbps by occupying less computing resources, and the algorithm has the ability to support hundreds of Gbps randomness extraction. By assuming that the eavesdropper with complete knowledge of the classical noise, our generator has a randomness generation speed of 6.83 Gbps and this supports the generation of 6 Gbps information-theoretically provable quantum random numbers, which are output in real-time through peripheral component interconnect express interface.
- 13top 1.4%
The Velociprobe: An ultrafast hard X-ray nanoprobe for high-resolution ptychographic imaging
Junjing Deng, Curt Preissner, Jeffrey A. Klug, Sheikh T. Mashrafi, Christian Roehrig and 14 more
91 citationsOpen access (CC-BY)doi:10.1063/1.5103173OpenAlex
Show abstractHide abstract
Motivated by the advanced photon source upgrade, a new hard X-ray microscope called “Velociprobe” has been recently designed and built for fast ptychographic imaging with high spatial resolution. We are addressing the challenges of high-resolution and fast scanning with novel hardware designs, advanced motion controls, and new data acquisition strategies, including the use of high-bandwidth interferometric measurements. The use of granite, air-bearing-supported stages provides the necessary long travel ranges for coarse motion to accommodate real samples and variable energy operation while remaining highly stable during fine scanning. Scanning the low-mass zone plate enables high-speed and high-precision motion of the probe over the sample. With an advanced control algorithm implemented in a closed-loop feedback system, the setup achieves a position resolution (3σ) of 2 nm. The instrument performance is evaluated by 2D fly-scan ptychography with our developed data acquisition strategies. A spatial resolution of 8.8 nm has been demonstrated on a Au test sample with a detector…
- 14top 1.5%
Cavity-enhanced high harmonic generation for extreme ultraviolet time- and angle-resolved photoemission spectroscopy
A. K. Mills, S. Zhdanovich, M. X. Na, F. Boschini, E. Razzoli and 8 more
89 citationsOpen accessdoi:10.1063/1.5090507OpenAlex
Show abstractHide abstract
With its direct correspondence to electronic structure, angle-resolved photoemission spectroscopy (ARPES) is a ubiquitous tool for the study of solids. When extended to the temporal domain, time-resolved (TR)-ARPES offers the potential to move beyond equilibrium properties, exploring both the unoccupied electronic structure as well as its dynamical response under ultrafast perturbation. Historically, ultrafast extreme ultraviolet sources employing high-order harmonic generation (HHG) have required compromises that make it challenging to achieve a high energy resolution—which is highly desirable for many TR-ARPES studies—while producing high photon energies and a high photon flux. We address this challenge by performing HHG inside a femtosecond enhancement cavity, realizing a practical source for TR-ARPES that achieves a flux of over 1011 photons/s delivered to the sample, operates over a range of 8–40 eV with a repetition rate of 60 MHz. This source enables TR-ARPES studies with a temporal and energy resolution of 190 fs and 22 meV, respectively. To characterize the system, we…
- 15top 1.6%
The upgraded Polaris powder diffractometer at the ISIS neutron source
Ronald I. Smith, S. Hull, Matthew G. Tucker, Helen Y. Playford, D.J. Mcphail and 2 more
86 citationsOpen access (CC-BY)doi:10.1063/1.5099568OpenAlex
Show abstractHide abstract
This paper describes the design and operation of the Polaris time-of-flight powder neutron diffractometer at the ISIS pulsed spallation neutron source, Rutherford Appleton Laboratory, UK. Following a major upgrade to the diffractometer in 2010-2011, its detector provision now comprises five large ZnS scintillator-based banks, covering an angular range of 6° ≤ 2θ ≤ 168°, with only minimal gaps between each bank. These detectors have a substantially increased solid angle coverage (Ω ∼ 5.67 sr) compared to the previous instrument (Ω ∼ 0.82 sr), resulting in increases in count rate of between 2× and 10×, depending on 2θ angle. The benefits arising from the high count rates achieved are illustrated using selected examples of experiments studying small sample volumes and performing rapid, time-resolved investigations. In addition, the enhanced capabilities of the diffractometer in the areas of in situ studies (which are facilitated by the installation of a novel design of radial collimator around the sample position and by a complementary programme of advanced sample environment…
- 16top 1.7%
MANTIS: A real-time quantitative multispectral imaging system for fusion plasmas
A. Perek, W.A.J. Vijvers, Y. Andrèbe, I. G. J. Classen, B.P. Duval and 8 more
84 citationsOpen accessdoi:10.1063/1.5115569OpenAlex
Show abstractHide abstract
This work presents a novel, real-time capable, 10-channel Multispectral Advanced Narrowband Tokamak Imaging System installed on the TCV tokamak, MANTIS. Software and hardware requirements are presented together with the complete system architecture. The image quality of the system is assessed with emphasis on effects resulting from the narrowband interference filters. Some filters are found to create internal reflection images that are correlated with the filters' reflection coefficient. This was measured for selected filters where significant absorption (up to 65% within ∼70 nm of the filter center) was measured. The majority of this was attributed to the filter's design, and several filters' performance is compared. Tailored real-time algorithms exploiting the system's capabilities are presented together with benchmarks comparing polling and event based synchronization. The real-time performance is demonstrated with a density ramp discharge performed on TCV. The behavior of spectral lines' emission from different plasma species and their interpretation are qualitatively described.
- 17top 1.8%
Characterizing atomic magnetic gradiometers for fetal magnetocardiography
Ibrahim Sulai, Zack DeLand, Michael Bulatowicz, Carl Wahl, Ronald T. Wakai and 1 more
79 citationsOpen accessdoi:10.1063/1.5091007OpenAlex
Show abstractHide abstract
Atomic magnetometers (AMs) offer many advantages over superconducting quantum interference devices due to, among other things, having comparable sensitivity while not requiring cryogenics. One of the major limitations of AMs is the challenge of configuring them as gradiometers. We report the development of a spin-exchange relaxation free vector atomic magnetic gradiometer with a sensitivity of 3 fT cm−1 Hz−1/2 and common mode rejection ratio >150 in the band from DC to 100 Hz. We introduce a background suppression figure of merit for characterizing the performance of gradiometers. It allows for optimally setting the measurement baseline and for quickly assessing the advantage, if any, of performing a measurement in a gradiometric mode. As an application, we consider the problem of fetal magnetocardiography (fMCG) detection in the presence of a large background maternal MCG signal.
- 18top 1.9%
Laser heating setup for diamond anvil cells for in situ synchrotron and in house high and ultra-high pressure studies
Timofey Fedotenko, Leonid Dubrovinsky, Georgios Aprilis, Egor Koemets, Anatoly A. Snigirev and 6 more
76 citationsdoi:10.1063/1.5117786OpenAlex
Show abstractHide abstract
The diamond anvil cell (DAC) technique combined with laser heating is one of the major methods for studying materials at high pressure and high temperature conditions. In this work, we present a transferable double-sided laser heating setup for DACs with in situ temperature determination. The setup allows precise heating of samples inside a DAC at pressures above 200 GPa and could be combined with synchrotron beamline equipment. It can be applied to X-ray diffraction and X-ray transmission microscopy experiments. In the setup, we use high-magnification and low working distance infinity corrected laser focusing objectives that enable us to decrease the size of the laser beam to less than 5 µm and achieve the maximum optical magnification of 320 times. All optical components of the setup were chosen to minimize chromatic and spatial aberrations for accurate in situ temperature determination by multiwavelength spectroscopy in the 570–830 nm spectral range. Flexible design of our setup allows simple interchange of laser sources and focusing optics for application in different types of…
- 19top 2%
Soft X-ray spectroscopy with transition-edge sensors at Stanford Synchrotron Radiation Lightsource beamline 10-1
Sang‐Jun Lee, Charles James Titus, Roberto Alonso‐Mori, Michael Lloyd Baker, D. A. Bennett and 25 more
73 citationsdoi:10.1063/1.5119155OpenAlex
Show abstractHide abstract
We present results obtained with a new soft X-ray spectrometer based on transition-edge sensors (TESs) composed of Mo/Cu bilayers coupled to bismuth absorbers. This spectrometer simultaneously provides excellent energy resolution, high detection efficiency, and broadband spectral coverage. The new spectrometer is optimized for incident X-ray energies below 2 keV. Each pixel serves as both a highly sensitive calorimeter and an X-ray absorber with near unity quantum efficiency. We have commissioned this 240-pixel TES spectrometer at the Stanford Synchrotron Radiation Lightsource beamline 10-1 (BL 10-1) and used it to probe the local electronic structure of sample materials with unprecedented sensitivity in the soft X-ray regime. As mounted, the TES spectrometer has a maximum detection solid angle of 2 × 10−3 sr. The energy resolution of all pixels combined is 1.5 eV full width at half maximum at 500 eV. We describe the performance of the TES spectrometer in terms of its energy resolution and count-rate capability and demonstrate its utility as a high throughput detector for…
- 20top 2.1%
Automated image processing method to quantify rotating detonation wave behavior
John W. Bennewitz, Blaine R. Bigler, Stephen A. Schumaker, William A. Hargus
72 citationsdoi:10.1063/1.5067256OpenAlex
Show abstractHide abstract
An image processing technique is developed to automatically determine both average and instantaneous detonation wave properties within a rotating detonation rocket engine (RDRE) using high-speed imaging. This method entails segmenting the imaged RDRE annulus into 200 azimuthal bins and tracking integrated pixel intensity in each bin. By combining individual pixel intensity temporal histories across the azimuthal bins, this provides what is termed a detonation surface that visualizes the propagation of the individual detonation fronts azimuthally around the annulus. Average detonation modal properties including wave speed Ūwv, operational frequency fdet, and the number of waves m are determined automatically through a two-dimensional Fourier analysis of the detonation surface data. Also, instantaneous wave speeds Uwv for each individual detonation are determined by taking the numerical derivative of each waves’ angular position temporal history from the detonation surface. This provides useful insight into wave-to-wave variability for an operating condition, as well as denoting modal…
- 21top 2.2%
Unifying obstacle detection, recognition, and fusion based on millimeter wave radar and RGB-depth sensors for the visually impaired
Ningbo Long, Kaiwei Wang, Ruiqi Cheng, Weijian Hu, Kailun Yang
68 citationsdoi:10.1063/1.5093279OpenAlex
Show abstractHide abstract
It is very difficult for visually impaired people to perceive and avoid obstacles at a distance. To address this problem, the unified framework of multiple target detection, recognition, and fusion is proposed based on the sensor fusion system comprising a low-power millimeter wave (MMW) radar and an RGB-Depth (RGB-D) sensor. In this paper, the Mask R-CNN and the single shot multibox detector network are utilized to detect and recognize the objects from color images. The obstacles' depth information is obtained from the depth images using the MeanShift algorithm. The position and velocity information on the multiple target is detected by the MMW radar based on the principle of a frequency modulated continuous wave. The data fusion based on the particle filter obtains more accurate state estimation and richer information by fusing the detection results from the color images, depth images, and radar data compared with using only one sensor. The experimental results show that the data fusion enriches the detection results. Meanwhile, the effective detection range is expanded compared…
- 22top 2.3%
A setup for extreme-ultraviolet ultrafast angle-resolved photoelectron spectroscopy at 50-kHz repetition rate
Jan Heye Buss, He Wang, Yiming Xu, Julian Maklar, Frédéric Joucken and 9 more
66 citationsOpen accessdoi:10.1063/1.5079677OpenAlex
Show abstractHide abstract
Time- and angle-resolved photoelectron spectroscopy (trARPES) is a powerful method to track the ultrafast dynamics of quasiparticles and electronic bands in energy and momentum space. We present a setup for trARPES with 22.3 eV extreme-ultraviolet (XUV) femtosecond pulses at 50-kHz repetition rate, which enables fast data acquisition and access to dynamics across momentum space with high sensitivity. The design and operation of the XUV beamline, pump-probe setup, and ultra-high vacuum endstation are described in detail. By characterizing the effect of space-charge broadening, we determine an ultimate source-limited energy resolution of 60 meV, with typically 80–100 meV obtained at 1–2 × 1010 photons/s probe flux on the sample. The instrument capabilities are demonstrated via both equilibrium and time-resolved ARPES studies of transition-metal dichalcogenides. The 50-kHz repetition rate enables sensitive measurements of quasiparticles at low excitation fluences in semiconducting MoSe2, with an instrumental time resolution of 65 fs. Moreover, photo-induced phase transitions can be…
- 23top 2.4%
A high-performance compact magnetic shield for optically pumped magnetometer-based magnetoencephalography
Kaiyan He, Shuangai Wan, Jingwei Sheng, Dongsu Liu, Chune Wang and 5 more
64 citationsdoi:10.1063/1.5066250OpenAlex
Show abstractHide abstract
The rapid development of the optically pumped magnetometer (OPM) has offered a much more flexible method for magnetoencephalography (MEG). Without using liquid helium and its associated dewar device in the OPM detectors, the large and expensive magnetically shielded room (MSR) for traditional MEG systems could be replaced by a compact shield. In the present work, an economic and compact cylindrical shield was designed and built to meet the low-field working requirement of the OPM in detecting human brain neuronal activities. The performance of the compact shield was evaluated and further compared with that of a commercial MSR. Our results showed that the residual magnetic fields and background noise of the compact shield were lower than or comparable to those of the MSR. The remnant field in the shield is found to be 4.2 nT, a factor of 13 000 smaller than the geomagnetic field which is applied to the transverse direction of the shield, and the longitudinal shielding factors measured using a known alternating-current magnetic field are approximately 191, 205, and 3130 at 0.1 Hz, 1…
- 24top 2.5%
A system for the synthesis of nanoparticles by laser ablation in liquid that is remotely controlled with PC or smartphone
Simone Crivellaro, Andrea Guadagnini, David Muñetón Arboleda, Daniel C. Schinca, Vincenzo Amendola
63 citationsOpen accessdoi:10.1063/1.5083811OpenAlex
Show abstractHide abstract
Nanoparticles find applications in multiple technological and scientific fields, and laser ablation in liquid (LAL) emerged as a versatile method for providing colloidal solutions of nanomaterials with various composition, by a low cost, simple, self-standing, and "green" procedure. However, the use of high energy and high power laser beams is harmful, especially when coupled with flammable or toxic liquids, and in situ operation is required for starting, monitoring the LAL synthesis, and stopping it at the desired point. Here we describe the hardware and software design and the test results of a system for the production of nanoparticles by laser ablation synthesis in liquid solution (LASiS), which is remotely controllable with a personal computer or a smartphone. In this system, laser energy and solution flux are selectable, and the synthesis status can be monitored and managed at any time off site. Only commercially available components and software are employed, making the whole apparatus easily reproducible in any LAL laboratory. The system has proven its reliability in various…
- 25top 2.6%
Multispectral multidimensional spectrometer spanning the ultraviolet to the mid-infrared
Yin Song, Arkaprabha Konar, Riley Sechrist, Ved Prakash Roy, Rong Duan and 5 more
63 citationsOpen accessdoi:10.1063/1.5055244OpenAlex
Show abstractHide abstract
Multidimensional spectroscopy is the optical analog to nuclear magnetic resonance, probing dynamical processes with ultrafast time resolution. At optical frequencies, the technical challenges of multidimensional spectroscopy have hindered its progress until recently, where advances in laser sources and pulse-shaping have removed many obstacles to its implementation. Multidimensional spectroscopy in the visible and infrared (IR) regimes has already enabled respective advances in our understanding of photosynthesis and the structural rearrangements of liquid water. A frontier of ultrafast spectroscopy is to extend and combine multidimensional techniques and frequency ranges, which have been largely restricted to operating in the distinct visible or IR regimes. By employing two independent amplifiers seeded by a single oscillator, it is straightforward to span a wide range of time scales (femtoseconds to seconds), all of which are often relevant to the most important energy conversion and catalysis problems in chemistry, physics, and materials science. Complex condensed phase systems…
- 26top 2.7%
An open-source high-frequency lock-in amplifier
G. A. Stimpson, M. S. Skilbeck, R. L. Patel, B. L. Green, Gavin W. Morley
61 citationsOpen access (CC-BY)doi:10.1063/1.5083797OpenAlex
Show abstractHide abstract
We present characterization of a lock-in amplifier based on a field programmable gate array capable of demodulation at up to 50 MHz. The system exhibits 90 nV/√Hz of input noise at an optimum demodulation frequency of 500 kHz. The passband has a full-width half-maximum of 2.6 kHz for modulation frequencies above 100 kHz. Our code is open source and operates on a commercially available platform.
- 27top 2.8%
Towards a transportable aluminium ion quantum logic optical clock
S. Hannig, L. Pelzer, N. Scharnhorst, J. Kramer, M. Stepanova and 5 more
61 citationsOpen access (CC-BY)doi:10.1063/1.5090583OpenAlex
Show abstractHide abstract
With the advent of optical clocks featuring fractional frequency uncertainties on the order of 10−17 and below, new applications such as chronometric leveling with few-centimeter height resolution emerge. We are developing a transportable optical clock based on a single trapped aluminum ion, which is interrogated via quantum logic spectroscopy. We employ singly charged calcium as the logic ion for sympathetic cooling, state preparation, and readout. Here, we present a simple and compact physics and laser package for manipulation of 40Ca+. Important features are a segmented multilayer trap with separate loading and probing zones, a compact titanium vacuum chamber, a near-diffraction-limited imaging system with high numerical aperture based on a single biaspheric lens, and an all-in-fiber 40Ca+ repump laser system. We present preliminary estimates of the trap-induced frequency shifts on 27Al+, derived from measurements with a single calcium ion. The micromotion-induced second-order Doppler shift for 27Al+ has been determined to be δνEMMν=−0.4−0.3+0.4×10−18 and the black-body radiation…
- 28top 2.9%
Pushing data quality for laboratory pair distribution function experiments
Sabrina L. J. Thomä, Nils Prinz, Thomas Hartmann, Michael Teck, Sascha Correll and 1 more
60 citationsOpen accessdoi:10.1063/1.5093714OpenAlex
Show abstractHide abstract
Over the last decade, some studies with laboratory pair distribution function (PDF) data emerged. Yet, limited Qmax or instrumental resolution impeded in-depth structural refinements. With more advanced detector technologies, the question arose how to design novel PDF equipment for laboratories that will allow decent PDF refinements over r = 1–70 Å. It is crucial to reflect the essential requirements, namely, monochromatic X-rays, suppression of air scattering, instrumental resolution, and overall measurement times. The result is a novel PDF setup based on a STOE STADI P powder diffractometer in transmission-/Debye-Scherrer geometry with monochromatic Ag Kα1 radiation, featuring a MYTHEN2 4K detector covering a Q range of 0.3–20.5 Å−1. PDF data are collected in a moving PDF mode within 6 h. Structural signatures of liquids can be satisfactorily resolved in the PDF as shown for the ionic liquid hmimPF6. The high instrumental resolution is mirrored in low qdamp values determined from LaB6 measurements. PDF data from a powder sample of ca. 7 nm TiO2 nanoparticles were successfully…
- 29top 3%
Magnetic field stabilization system for atomic physics experiments
B. Merkel, K. Thirumalai, J. E. Tarlton, V. M. Schäfer, Christopher J. Ballance and 2 more
59 citationsOpen accessdoi:10.1063/1.5080093OpenAlex
Show abstractHide abstract
Atomic physics experiments commonly use millitesla-scale magnetic fields to provide a quantization axis. As atomic transition frequencies depend on the magnitude of this field, many experiments require a stable absolute field. Most setups use electromagnets, which require a power supply stability not usually met by commercially available units. We demonstrate the stabilization of a field of 14.6 mT to 4.3 nT rms noise (0.29 ppm), compared to noise of >100 nT without any stabilization. The rms noise is measured using a field-dependent hyperfine transition in a single 43Ca+ ion held in a Paul trap at the center of the magnetic field coils. For the 43Ca+ “atomic clock” qubit transition at 14.6 mT, which depends on the field only in second order, this would yield a projected coherence time of many hours. Our system consists of a feedback loop and a feedforward circuit that control the current through the field coils and could easily be adapted to other field amplitudes, making it suitable for other applications such as neutral atom traps.
- 30top 3.1%
Johann-type laboratory-scale x-ray absorption spectrometer with versatile detection modes
A. Honkanen, Sami Ollikkala, Taru Ahopelto, Antti‐Jussi Kallio, Merja Blomberg and 1 more
59 citationsOpen accessdoi:10.1063/1.5084049OpenAlex
Show abstractHide abstract
We present a low-cost laboratory X-ray absorption spectrometer that uses a conventional X-ray tube source and bent Johann-type crystal monochromators. The instrument is designed for X-ray absorption spectroscopy studies in the 4-20 keV range which covers most K edges of 3d transition metals and L edges of 5d transition metals and actinides. The energy resolution is typically in the range of 1-5 eV at 10 keV depending on the crystal analyser and the Bragg angle. Measurements can be performed in transmission, fluorescence, and imaging modes. Due to its simple and modular design, the spectrometer can be modified to accommodate additional equipment and complex sample environments required for in situ studies. A showcase of various applications is presented.
- 31top 3.2%
The laser shock station in the dynamic compression sector. I
Xiaoming Wang, Paulo A. Rigg, J. D. Sethian, Nicholas W. Sinclair, Nicholas Weir and 11 more
54 citationsdoi:10.1063/1.5088367OpenAlex
Show abstractHide abstract
The Laser Shock Station in the Dynamic Compression Sector (DCS) [Advanced Photon Source (APS), Argonne National Laboratory] links a laser-driven shock compression platform with high energy x-ray pulses from the APS to achieve in situ, time-resolved x-ray measurements (diffraction and imaging) in materials subjected to well-characterized, high stress, short duration shock waves. This station and the other DCS experimental stations provide a unique and versatile facility to study condensed state phenomena subjected to shocks with a wide range of amplitudes (to above ∼350 GPa) and time-durations (∼10 ns-1 µs). The Laser Shock Station uses a 100 J, 5-17 ns, 351 nm frequency tripled Nd:glass laser with programmable pulse shaping and focal profile smoothing for maximum precision. The laser can operate once every 30 min. The interaction chamber has multiple diagnostic ports, a sample holder to expose 14 samples without breaking vacuum, can vary the angle between the x-ray and laser beams by 135°, and can translate to select one of the two types of x-ray beams. The x-ray measurement…
- 32top 3.3%
Piezoelectric-based uniaxial pressure cell with integrated force and displacement sensors
Mark Edward Barber, Alexander Steppke, Andrew Peter Mackenzie, Clifford W. Hicks
54 citationsOpen accessdoi:10.1063/1.5075485OpenAlex
Show abstractHide abstract
We present a design for a piezoelectric-driven uniaxial stress cell suitable for use at ambient and cryogenic temperatures and that incorporates both a displacement and a force sensor. The cell has a diameter of 46 mm and a height of 13 mm. It can apply a zero-load displacement of up to ∼45 μm and a zero-displacement force of up to ∼245 N. With combined knowledge of the displacement and force applied to the sample, it can quickly be determined whether the sample and its mounts remain within their elastic limits. In tests on the oxide metal Sr2RuO4, we found that at room temperature serious plastic deformation of the sample onset at a uniaxial stress of ∼0.2 GPa, while at 5 K the sample deformation remained elastic up to almost 2 GPa. This result highlights the usefulness of in situ tuning, in which the force can be applied after cooling samples to cryogenic temperatures.
- 33top 3.4%
Closed-cycle, low-vibration 4 K cryostat for ion traps and other applications
P. Micke, J. Stark, S. A. King, Tobias Leopold, T. Pfeifer and 5 more
53 citationsOpen access (CC-BY)doi:10.1063/1.5088593OpenAlex
Show abstractHide abstract
In vacuo cryogenic environments are ideal for applications requiring both low temperatures and extremely low particle densities. This enables reaching long storage and coherence times, for example, in ion traps, essential requirements for experiments with highly charged ions, quantum computation, and optical clocks. We have developed a novel cryostat continuously refrigerated with a pulse-tube cryocooler and providing the lowest vibration level reported for such a closed-cycle system with 1 W cooling power for a <5 K experiment. A decoupling system suppresses vibrations from the cryocooler by three orders of magnitude down to a level of 10 nm peak amplitudes in the horizontal plane. Heat loads of about 40 W (at 45 K) and 1 W (at 4 K) are transferred from an experimental chamber, mounted on an optical table, to the cryocooler through a vacuum-insulated massive 120 kg inertial copper pendulum. The 1.4 m long pendulum allows installation of the cryocooler in a separate, acoustically isolated machine room. At the experimental chamber, we measured the residual vibrations using an…
- 34top 3.5%
New dynamic diamond anvil cells for tera-pascal per second fast compression x-ray diffraction experiments
Zsolt Jenei, Hanns‐Peter Liermann, Rachel J. Husband, Alba San José Méndez, David Pennicard and 13 more
53 citationsOpen accessdoi:10.1063/1.5098993OpenAlex
Show abstractHide abstract
Fast compression experiments performed using dynamic diamond anvil cells (dDACs) employing piezoactuators offer the opportunity to study compression-rate dependent phenomena. In this paper, we describe an experimental setup which allows us to perform time-resolved x-ray diffraction during the fast compression of materials using improved dDACs. The combination of the high flux available using a 25.6 keV x-ray beam focused with a linear array of compound refractive lenses and the two fast GaAs LAMBDA detectors available at the Extreme Conditions Beamline (P02.2) at PETRA III enables the collection of x-ray diffraction patterns at an effective repetition rate of up to 4 kHz. Compression rates of up to 160 TPa/s have been achieved during the compression of gold in a 2.5 ms fast compression using improved dDAC configurations with more powerful piezoactuators. The application of this setup to low-Z compounds at lower compression rates is described, and the high temporal resolution of the setup is demonstrated. The possibility of applying finely tuned pressure profiles opens opportunities…
- 35top 3.6%
The Crystal Backlighter Imager: A spherically bent crystal imager for radiography on the National Ignition Facility
Gareth N. Hall, Christine M. Krauland, M. S. Schollmeier, Gregory E. Kemp, J. G. Buscho and 22 more
53 citationsdoi:10.1063/1.5058700OpenAlex
Show abstractHide abstract
The Crystal Backlighter Imager (CBI) is a quasi-monochromatic, near-normal incidence, spherically bent crystal imager developed for the National Ignition Facility (NIF), which will allow inertial confinement fusion capsule implosions to be radiographed close to stagnation. This is not possible using the standard pinhole-based area-backlighter configuration, as the self-emission from the capsule hotspot overwhelms the backlighter signal in the final stages of the implosion. The CBI mitigates the broadband self-emission from the capsule hot spot by using the extremely narrow bandwidth inherent to near-normal-incidence Bragg diffraction. Implementing a backlighter system based on near-normal reflection in the NIF chamber presents unique challenges, requiring the CBI to adopt novel engineering and operational strategies. The CBI currently operates with an 11.6 keV backlighter, making it the highest energy radiography diagnostic based on spherically bent crystals to date. For a given velocity, Doppler shift is proportional to the emitted photon energy. At 11.6 keV, the ablation velocity…
- 36top 3.7%
A cryogenic radio-frequency ion trap for quantum logic spectroscopy of highly charged ions
T. Leopold, S. A. King, P. Micke, A. Bautista-Salvador, J. C. Heip and 3 more
50 citationsOpen access (CC-BY)doi:10.1063/1.5100594OpenAlex
Show abstractHide abstract
A cryogenic radio-frequency ion trap system designed for quantum logic spectroscopy of highly charged ions (HCI) is presented. It includes a segmented linear Paul trap, an in-vacuum imaging lens, and a helical resonator. We demonstrate ground state cooling of all three modes of motion of a single 9Be+ ion and determine their heating rates as well as excess axial micromotion. The trap shows one of the lowest levels of electric field noise published to date. We investigate the magnetic-field noise suppression in cryogenic shields made from segmented copper, the resulting magnetic field stability at the ion position and the resulting coherence time. Using this trap in conjunction with an electron beam ion trap and a deceleration beamline, we have been able to trap single highly charged Ar13+ (Ar XIV) ions concurrently with single Be+ ions, a key prerequisite for the first quantum logic spectroscopy of a HCI. This major stepping stone allows us to push highly-charged-ion spectroscopic precision from the gigahertz to the hertz level and below.
- 37top 3.8%
Development of high-speed ion conductance microscopy
Shinji Watanabe, Satoko Kitazawa, Linhao Sun, Noriyuki Kodera, Toshio Ando
48 citationsOpen accessdoi:10.1063/1.5118360OpenAlex
Show abstractHide abstract
Scanning ion conductance microscopy (SICM) can image the surface topography of specimens in ionic solutions without mechanical probe-sample contact. This unique capability is advantageous for imaging fragile biological samples but its highest possible imaging rate is far lower than the level desired in biological studies. Here, we present the development of high-speed SICM. The fast imaging capability is attained by a fast Z-scanner with active vibration control and pipette probes with enhanced ion conductance. By the former, the delay of probe Z-positioning is minimized to sub-10 µs, while its maximum stroke is secured at 6 μm. The enhanced ion conductance lowers a noise floor in ion current detection, increasing the detection bandwidth up to 100 kHz. Thus, temporal resolution 100-fold higher than that of conventional systems is achieved, together with spatial resolution around 20 nm.
- 38top 3.9%
Upgrade to the MAPS neutron time-of-flight chopper spectrometer
R. A. Ewings, J. R. Stewart, T. G. Perring, R. I. Bewley, M. D. Le and 7 more
48 citationsOpen accessdoi:10.1063/1.5086255OpenAlex
Show abstractHide abstract
The MAPS direct geometry time-of-flight chopper spectrometer at the ISIS pulsed neutron and muon source has been in operation since 1999, and its novel use of a large array of position-sensitive neutron detectors paved the way for a later generations of chopper spectrometers around the world. Almost two decades of experience of user operations on MAPS, together with lessons learned from the operation of new generation instruments, led to a decision to perform three parallel upgrades to the instrument. These were to replace the primary beamline collimation with supermirror neutron guides, to install a disk chopper, and to modify the geometry of the poisoning in the water moderator viewed by MAPS. Together, these upgrades were expected to increase the neutron flux substantially, to allow more flexible use of repetition rate multiplication and to reduce some sources of background. Here, we report the details of these upgrades and compare the performance of the instrument before and after their installation as well as to Monte Carlo simulations. These illustrate that the instrument is…
- 39top 4%
Multimode scanning X-ray diffraction microscopy for diamond anvil cell experiments
Rostislav Hrubiak, Jesse S. Smith, Guoyin Shen
47 citationsOpen accessdoi:10.1063/1.5057518OpenAlex
Show abstractHide abstract
We have designed and implemented a new experimental system for fast mapping of crystal structures and other structural features of materials under high pressure at the High Pressure Collaborative Access Team, Sector 16 of the Advanced Photon Source. The system utilizes scanning X-ray diffraction microscopy (SXDM) and is optimized for use with diamond anvil cell devices. In SXDM, the X-ray diffraction (XRD) is collected in a forward scattering geometry from points on a two-dimensional grid by fly-scanning the sample with respect to a micro-focused X-ray beam. The recording of XRD is made during the continuous motion of the sample using a fast (millisecond) X-ray area detector in synchrony with the sample positioners, resulting in a highly efficient data collection for SXDM. A new computer program, X-ray Diffractive Imaging (XDI), has been developed with the SXDM system. The XDI program provides a graphical interface for constructing and displaying the SXDM images in several modes: (1) phase mapping based on structural information, (2) pressure visualization based on the equation of…
- 40top 4.1%
Ultra-low noise magnetic field for quantum gases
Xiao-Tian Xu, Zong-Yao Wang, Rui-Heng Jiao, Chang-Rui Yi, Wei Sun and 1 more
46 citationsOpen accessdoi:10.1063/1.5087957OpenAlex
Show abstractHide abstract
A ultralow noise magnetic field is essential for many branches of scientific research. Examples include experiments conducted on ultracold atoms, quantum simulations, and precision measurements. In ultracold atom experiments specifically, a bias magnetic field will often serve as a quantization axis and be applied for Zeeman splitting. As atomic states are usually sensitive to magnetic fields, a magnetic field characterized by ultralow noise as well as high stability is typically required for experimentation. For this study, a bias magnetic field is successfully stabilized at 14.5 G, with the root mean square value of the noise reduced to 18.5 μG (1.28 ppm) by placing μ-metal magnetic shields together with a dynamical feedback circuit. Long-time instability is also regulated consistently below 7 μG. The level of noise exhibited in the bias magnetic field is further confirmed by evaluating the coherence time of a Bose-Einstein condensate characterized by Rabi oscillation. It is concluded that this approach can be applied to other physical systems as well.
- 41top 4.2%
J-NSE-Phoenix, a neutron spin-echo spectrometer with optimized superconducting precession coils at the MLZ in Garching
Stefano Pasini, Olaf Holderer, T. Kozielewski, Dieter Richter, Michael Monkenbusch
45 citationsdoi:10.1063/1.5084303OpenAlex
Show abstractHide abstract
A novel set of superconducting main precession coils has been built and installed in the Jülich-neutron spin-echo (J-NSE) spectrometer at the Heinz Maier-Leibnitz Zentrum (MLZ) in Garching. These unique new coils comprise a field-integral optimizing field shape, fringe field compensation, and high stability. They yield an enhancement of a factor of 2.5 in the intrinsic field-integral homogeneity, i.e., the resolution. The coil concept has been developed for the ESSENSE instrument proposal for the European Spallation Source. We report on the construction of and on the first results from the new superconducting neutron spin-echo spectrometer at the MLZ in Garching where the coils are the main part of a refurbishment of the J-NSE spectrometer after twenty years of operation.
- 42top 4.3%
Scanning tunneling state recognition with multi-class neural network ensembles
O. Gordon, P. D’Hondt, L. Knijff, S. E. Freeney, Filipe L. Q. Junqueira and 2 more
44 citationsOpen access (CC-BY)doi:10.1063/1.5099590OpenAlex
Show abstractHide abstract
One of the largest obstacles facing scanning probe microscopy is the constant need to correct flaws in the scanning probe in situ. This is currently a manual, time-consuming process that would benefit greatly from automation. Here, we introduce a convolutional neural network protocol that enables automated recognition of a variety of desirable and undesirable scanning tunneling tip states on both metal and nonmetal surfaces. By combining the best performing models into majority voting ensembles, we find that the desirable states of H:Si(100) can be distinguished with a mean precision of 0.89 and an average receiver-operator-characteristic curve area of 0.95. More generally, high and low-quality tips can be distinguished with a mean precision of 0.96 and near perfect area-under-curve of 0.98. With trivial modifications, we also successfully automatically identify undesirable, non-surface-specific states on surfaces of Au(111) and Cu(111). In these cases, we find mean precisions of 0.95 and 0.75 and area-under-curves of 0.98 and 0.94, respectively. Provided that training data are…
- 43top 4.4%
AC elastocaloric effect as a probe for thermodynamic signatures of continuous phase transitions
M. Ikeda, Joshua A. W. Straquadine, Alexander T. Hristov, Thanapat Worasaran, Johanna C. Palmstrom and 3 more
44 citationsOpen accessdoi:10.1063/1.5099924OpenAlex
Show abstractHide abstract
Studying the response of materials to strain can elucidate subtle properties of the electronic structure in strongly correlated materials. Here, we focus on the elastocaloric coefficients, forming a second rank tensor quantity describing the relation between entropy and strain. In contrast to the better-known elastoresistivity, the elastocaloric effect is a thermodynamic quantity. Experimentally, elastocaloric effect measurements are demanding since the thermodynamic conditions during the measurement have to be well controlled. In this work, we present a technique to measure the elastocaloric effect under quasiadiabatic conditions. The technique is based on oscillating strain, which allows for increasing the frequency of the elastocaloric effect above the thermal relaxation rate of the sample. We apply the technique to Co-doped iron pnictide superconductors and show that the thermodynamic signatures of second order phase transitions in the elastocaloric effect closely follow those observed in calorimetry experiments. In contrast to heat capacity, elastocaloric effect measurements…
- 44top 4.5%
Langmuir probe electronics upgrade on the tokamak à configuration variable
H. De Oliveira, Ph. Marmillod, C. Theiler, René Chavan, O. Février and 5 more
44 citationsOpen access (CC-BY)doi:10.1063/1.5108876OpenAlex
Show abstractHide abstract
A detailed description of the Langmuir probe electronics upgrade for TCV (Tokamak à Configuration Variable) is presented. The number of amplifiers and corresponding electronics has been increased from 48 to 120 in order to simultaneously connect all of the 114 Langmuir probes currently mounted in the TCV divertor and main-wall tiles. Another set of 108 amplifiers is ready to be installed in order to connect 80 new probes, built in the frame of the TCV divertor upgrade. Technical details of the amplifier circuitry are discussed as well as improvements over the first generation of amplifiers developed at SPC (formerly CRPP) in 1993/1994 and over the second generation developed in 2012/2013. While the new amplifiers have been operated successfully for over a year, it was found that their silicon power transistors can be damaged during some off-normal plasma events. Possible solutions are discussed.
- 45top 4.6%
A compact laser system for a portable atom interferometry gravimeter
Qin Luo, Heng Zhang, Ke Zhang, Xiao‐Chun Duan, Zhong-Kun Hu and 2 more
44 citationsdoi:10.1063/1.5053132OpenAlex
Show abstractHide abstract
A compact laser system for a portable 87Rb atom interferometry gravimeter has been demonstrated in this work. This laser system is based on frequency doubling of a single seed laser at the wavelength of 1560 nm. The frequency of the seed laser is controlled by a digital unit with an analog feedback circuit. By using this frequency control method, the frequency of the laser system can be shifted over 1 GHz. Based on this method, the Raman frequency can be locked on the F = 3 → F′ = 4 transition of 85Rb atoms. Moreover, the Raman sideband and the repumping laser are generated by a phase modulator, and it can generate different laser frequencies to meet the requirements of a typical atom interferometer. Additional sidebands in the Raman beam produced from the phase modulator are optimized and reduced, allowing us to observe atom interference with a free evolution time of 320 ms. The control unit including the laser system has been integrated into a box with a volume of 1.5 m × 0.6 m × 0.6 m, and the weight of which is only 150 kg. Using this compact optical scheme, our atomic…
- 46top 4.7%
A 3D-printed broadband millimeter wave absorber
Matthew A. Petroff, John W. Appel, Karwan Rostem, C. L. Bennett, Joseph R. Eimer and 3 more
44 citationsOpen accessdoi:10.1063/1.5050781OpenAlex
Show abstractHide abstract
We present the design, manufacturing technique, and characterization of a 3D-printed broadband graded index millimeter wave absorber. The absorber is additively manufactured using a fused filament fabrication 3D printer out of a carbon-loaded high impact polystyrene filament and is designed using a space-filling curve to optimize manufacturability using the said process. The absorber's reflectivity is measured from 63 GHz to 115 GHz and from 140 GHz to 215 GHz and is compared to electromagnetic simulations. The intended application is for terminating stray light in cosmic microwave background telescopes, and the absorber has been shown to survive cryogenic thermal cycling.
- 47top 4.8%
Integration of triaxial testing and pore-scale visualization of methane hydrate bearing sediments
Yongkoo Seol, Liang Lei, Jeong‐Hoon Choi, Karl Jarvis, Daniel Hill
43 citationsdoi:10.1063/1.5125445OpenAlex
Show abstractHide abstract
Understanding mechanical interactions between hydrate and hosting sediments is critical for evaluating formation stability and associated environmental impacts of hydrate-bearing sediments during gas production. While core-scale studies of hydrate-bearing sediments are readily available and some explanations of observed results rely on pore-scale behavior of hydrate, actual pore-scale observations supporting the larger-scale phenomena are rarely available for hydrate-bearing sediments, especially with methane as guest molecules. The primary reasons for the scarcity include the challenge of developing tools for small-scale testing apparatus and pore-scale visualization capability. We present a testing assembly that combines pore-scale visualization and triaxial test capability of methane hydrate-bearing sediments. This testing assembly allows temperature regulation and independent control of four pressures: influent and effluent pore pressure, confining pressure, and axial pressure. Axial and lateral effective stresses can be applied independently to a 9.5 mm diameter and 19 mm long…
- 48top 4.9%
Design, characterization, and performance of a hard x-ray transmission microscope at the National Synchrotron Light Source II 18-ID beamline
David Scott Coburn, Evgeny Nazaretski, Weihe Xu, Mingyuan Ge, Cindy Longo and 6 more
43 citationsOpen accessdoi:10.1063/1.5088124OpenAlex
Show abstractHide abstract
A transmission X-ray microscope has been designed and commissioned at the 18-ID Full-field X-ray Imaging beamline at the National Synchrotron Light Source II. This instrument operates in the 5-11 keV range, and, with the current set of optics, is capable of 30 nm spatial resolution imaging, with a field of view of about 40 μm. For absorption contrast, the minimum exposure time for a single projection image is about 20 ms and an entire 3D tomography data set can be acquired in under 1 min. The system enables tomographic reconstructions with sub-50 nm spatial resolution without the use of markers on the sample or corrections for rotation run-outs.
- 49top 5%
A transition-edge sensor-based x-ray spectrometer for the study of highly charged ions at the National Institute of Standards and Technology electron beam ion trap
P. Szypryt, G. C. O’Neil, Endre Takács, J. N. Tan, S. W. Buechele and 13 more
42 citationsOpen accessdoi:10.1063/1.5116717OpenAlex
Show abstractHide abstract
We report on the design, commissioning, and initial measurements of a Transition-Edge Sensor (TES) x-ray spectrometer for the Electron Beam Ion Trap (EBIT) at the National Institute of Standards and Technology (NIST). Over the past few decades, the NIST EBIT has produced numerous studies of highly charged ions in diverse fields such as atomic physics, plasma spectroscopy, and laboratory astrophysics. The newly commissioned NIST EBIT TES Spectrometer (NETS) improves the measurement capabilities of the EBIT through a combination of high x-ray collection efficiency and resolving power. NETS utilizes 192 individual TES x-ray microcalorimeters (166/192 yield) to improve upon the collection area by a factor of ∼30 over the 4-pixel neutron transmutation doped germanium-based microcalorimeter spectrometer previously used at the NIST EBIT. The NETS microcalorimeters are optimized for the x-ray energies from roughly 500 eV to 8000 eV and achieve an energy resolution of 3.7 eV-5.0 eV over this range, a more modest (<2×) improvement over the previous microcalorimeters. Beyond this energy range,…
- 50top 5.1%
An integrated instrument of DUV-IR photoionization mass spectrometry and spectroscopy for neutral clusters
Hanyu Zhang, Haiming Wu, Yuhan Jia, Lijun Geng, Zhixun Luo and 2 more
42 citationsdoi:10.1063/1.5108994OpenAlex
Show abstractHide abstract
We have developed an integrated instrument combining deep ultraviolet laser ionization mass spectrometry (DUV-LIMS) and infrared multiphoton dissociation (IR-MPD) spectroscopy, abbreviated as DUV-IR. The 177.3 nm DUV laser (7 eV single-photon energy) has short pulse duration (15 ps) and appropriate pulse energy (∼20 µJ), which is found to be highly efficient for low-fragment photoionization of neutral metal clusters and molecules. A home-made cluster source is designed with an adjustable formation channel suitable for the generation of different cluster series. The well-aligned components of the reflection time-of-flight mass spectrometer, as well as the coaxial design of DUV laser and molecular beam, bring forth high sensitivity and high resolution of the DUV-LIMS. Taking these advantages, well-resolved neutral Vn (n = 1–43) and (Benzene)n (n = 1–25) clusters have been generated free of fragmentation. In addition to the generation and detection of neutral clusters, a fast-flow reaction tube is also designed downstream of the cluster source allowing to study their reactivity. In…
How to read this list
The cohort is every article, review and book chapter OpenAlex attributes to Review of Scientific Instruments with publication year 2019, excluding retracted works and paratext such as editorials and errata. The top 50 by citation count are listed; the percentile is the rank divided by the cohort size. 50 of the 50 entries have an abstract in OpenAlex. Counts were read on 29 October 2026 and will not be updated on this page, so a quoted rank stays verifiable. Full rules on the methodology page.
Other journals, same idea
Work with these 25 papers in Kahubi
- The papers land in your library with their DOIs
- Ask anything across all of them, with citations
- Draft a literature review from the same sources
Free plan, no card. Your files stay private unless you share them.
Reading several of these?
Kahubi reads papers with you, keeps every citation traceable and drafts with sources you can check. Free plan, no card.