Most-cited articles · 2016
The 50 most-cited articles in Review of Scientific Instruments, 2016
Ranked by OpenAlex citation count on 29 October 2026, out of 1,384 eligible articles Review of Scientific Instruments published in 2016. Ranks are frozen; this page will not change. Number one, with 267 citations: Contributed Review: Distributed optical fibre dynamic strain sensing.
- Cohort
- 1,384 articles
- Listed
- Top 50 (3.6%)
- Open access
- 33 of 50
- Snapshot
- 2026-10-29
The most-cited articles from Review of Scientific Instruments in 2016 are led by review and instrumentation papers in optics, spectroscopy, and plasma diagnostics. The top paper, a contributed review on distributed optical fibre dynamic strain sensing by Masoudi and Newson, has 267 citations. Other highly cited works include an invited review on pump-probe microscopy with 253 citations and a paper on infrared ion spectroscopy in a modified quadrupole ion trap mass spectrometer at the FELIX free electron laser laboratory with 219 citations.
Readers can use this ranked list to identify the instruments, methods, and review topics that attracted the most citation attention among the 1384 eligible articles published in the journal in 2016. The entries reflect a range of subjects, including optical sensing, microscopy, mass spectrometry, plasma measurement, magnetic sensing, and energy harvesting.
Introduction written from the titles and abstracts on this list. Every figure below is the source.
Ask about these papers
Grounded in this list only, with sources.
- 1top 0.1%
Contributed Review: Distributed optical fibre dynamic strain sensing
Ali Masoudi, Trevor P. Newson
267 citationsOpen accessdoi:10.1063/1.4939482OpenAlex
Show abstractHide abstract
Extensive research on Brillouin- and Raman-based distributed optical fibre sensors over the past two decades has resulted in the commercialization of distributed sensors capable of measuring static and quasi-static phenomena such as temperature and strain. Recently, the focus has been shifted towards developing distributed sensors for measurement of dynamic phenomena such as dynamic strain and sound waves. This article reviews the current state of the art distributed optical fibre sensors capable of quantifying dynamic vibrations. The most important aspect of Rayleigh and Brillouin scattering processes which have been used for distributed dynamic measurement are studied. The principle of the sensing techniques used to measure dynamic perturbations are analyzed followed by a case study of the most recent advances in this field. It is shown that the Rayleigh-based sensors have longer sensing range and higher frequency range, but their spatial resolution is limited to 1 m. On the other hand, the Brillouin-based sensors have shown a higher spatial resolution, but relatively lower…
- 2top 0.2%
Invited Review Article: Pump-probe microscopy
Martin C. Fischer, Jesse W. Wilson, Francisco E. Robles, Warren S. Warren
253 citationsOpen accessdoi:10.1063/1.4943211OpenAlex
Show abstractHide abstract
Multiphoton microscopy has rapidly gained popularity in biomedical imaging and materials science because of its ability to provide three-dimensional images at high spatial and temporal resolution even in optically scattering environments. Currently the majority of commercial and home-built devices are based on two-photon fluorescence and harmonic generation contrast. These two contrast mechanisms are relatively easy to measure but can access only a limited range of endogenous targets. Recent developments in fast laser pulse generation, pulse shaping, and detection technology have made accessible a wide range of optical contrasts that utilize multiple pulses of different colors. Molecular excitation with multiple pulses offers a large number of adjustable parameters. For example, in two-pulse pump-probe microscopy, one can vary the wavelength of each excitation pulse, the detection wavelength, the timing between the excitation pulses, and the detection gating window after excitation. Such a large parameter space can provide much greater molecular specificity than existing…
- 3top 0.3%
Infrared ion spectroscopy in a modified quadrupole ion trap mass spectrometer at the FELIX free electron laser laboratory
Jonathan K. Martens, Giel Berden, Christoph R. Gebhardt, Jos Oomens
219 citationsOpen accessdoi:10.1063/1.4964703OpenAlex
Show abstractHide abstract
We report on modifications made to a Paul-type quadrupole ion trap mass spectrometer and discuss its application in infrared ion spectroscopy experiments. Main modifications involve optical access to the trapped ions and hardware and software coupling to a variety of infrared laser sources at the FELIX infrared free electron laser laboratory. In comparison to previously described infrared ion spectroscopy experiments at the FELIX laboratory, we find significant improvements in efficiency and sensitivity. Effects of the trapping conditions of the ions on the IR multiple photon dissociation spectra are explored. Enhanced photo-dissociation is found at lower pressures in the ion trap. Spectra obtained under reduced pressure conditions are found to more closely mimic those obtained in the high-vacuum conditions of an Fourier transform ion cyclotron resonance mass spectrometer. A gas-mixing system is described enabling the controlled addition of a secondary gas into helium buffer gas flowing into the trap and allows for ion/molecule reactions in the trap. The electron transfer…
- 4top 0.3%
Initial measurements of plasma current and electron density profiles using a polarimeter/interferometer (POINT) for long pulse operation in EAST (invited)
Haiqing Liu, J.P. Qian, Y. X. Jie, W. X. Ding, David L. Brower and 11 more
176 citationsdoi:10.1063/1.4963378OpenAlex
Show abstractHide abstract
A double-pass, radially viewing, far-infrared laser-based POlarimeter-INTerferometer (POINT) system utilizing the three-wave technique has been implemented for diagnosing the plasma current and electron density profiles in the Experimental Advanced Superconducting Tokamak (EAST). POINT has been operated routinely during the most recent experimental campaign and provides continuous 11 chord line-integrated Faraday effect and density measurement throughout the entire plasma discharge for all heating schemes and all plasma conditions (including ITER relevant scenario development). Reliability of both the polarimetric and interferometric measurements is demonstrated in 25 s plasmas with H-mode and 102 s long-pulse discharges. Current density, safety factor (q), and electron density profiles are reconstructed using equilibrium fitting code (EFIT) with POINT constraints for the plasma core.
- 5top 0.4%
Uncertainty analysis of thermoreflectance measurements
Jia Yang, Elbara Ziade, Aaron J. Schmidt
174 citationsdoi:10.1063/1.4939671OpenAlex
Show abstractHide abstract
We derive a generally applicable formula to calculate the precision of multi-parameter measurements that apply least squares algorithms. This formula, which accounts for experimental noise and uncertainty in the controlled model parameters, is then used to analyze the uncertainty of thermal property measurements with pump-probe thermoreflectance techniques. We compare the uncertainty of time domain thermoreflectance and frequency domain thermoreflectance (FDTR) when measuring bulk materials and thin films, considering simultaneous measurements of various combinations of thermal properties, including thermal conductivity, heat capacity, and thermal boundary conductance. We validate the uncertainty analysis using Monte Carlo simulations on data from FDTR measurements of an 80 nm gold film on fused silica.
- 6top 0.5%
Fabrication of all diamond scanning probes for nanoscale magnetometry
Patrick Appel, Elke Neu, Marc Ganzhorn, Arne Barfuss, Marietta Batzer and 3 more
171 citationsOpen access (CC-BY)doi:10.1063/1.4952953OpenAlex
Show abstractHide abstract
The electronic spin of the nitrogen vacancy (NV) center in diamond forms an atomically sized, highly sensitive sensor for magnetic fields. To harness the full potential of individual NV centers for sensing with high sensitivity and nanoscale spatial resolution, NV centers have to be incorporated into scanning probe structures enabling controlled scanning in close proximity to the sample surface. Here, we present an optimized procedure to fabricate single-crystal, all-diamond scanning probes starting from commercially available diamond and show a highly efficient and robust approach for integrating these devices in a generic atomic force microscope. Our scanning probes consisting of a scanning nanopillar (200 nm diameter, 1-2 μm length) on a thin (<1 μm) cantilever structure enable efficient light extraction from diamond in combination with a high magnetic field sensitivity (ηAC≈50±20nT/Hz). As a first application of our scanning probes, we image the magnetic stray field of a single Ni nanorod. We show that this stray field can be approximated by a single dipole and estimate the…
- 7top 0.6%
Contributed Review: Source-localization algorithms and applications using time of arrival and time difference of arrival measurements
Xinya Li, Zhiqun Daniel Deng, Lynn T. Rauchenstein, Thomas J. Carlson
167 citationsOpen access (CC-BY)doi:10.1063/1.4947001OpenAlex
Show abstractHide abstract
Locating the position of fixed or mobile sources (i.e., transmitters) based on measurements obtained from sensors (i.e., receivers) is an important research area that is attracting much interest. In this paper, we review several representative localization algorithms that use time of arrivals (TOAs) and time difference of arrivals (TDOAs) to achieve high signal source position estimation accuracy when a transmitter is in the line-of-sight of a receiver. Circular (TOA) and hyperbolic (TDOA) position estimation approaches both use nonlinear equations that relate the known locations of receivers and unknown locations of transmitters. Estimation of the location of transmitters using the standard nonlinear equations may not be very accurate because of receiver location errors, receiver measurement errors, and computational efficiency challenges that result in high computational burdens. Least squares and maximum likelihood based algorithms have become the most popular computational approaches to transmitter location estimation. In this paper, we summarize the computational…
- 8top 0.6%
Broadband, large-area microwave antenna for optically detected magnetic resonance of nitrogen-vacancy centers in diamond
Kento Sasaki, Yasuaki Monnai, Soya Saijo, Ryushiro Fujita, Hideyuki Watanabe and 3 more
165 citationsOpen accessdoi:10.1063/1.4952418OpenAlex
Show abstractHide abstract
We report on a microwave planar ring antenna specifically designed for optically detected magnetic resonance (ODMR) of nitrogen-vacancy (NV) centers in diamond. It has the resonance frequency at around 2.87 GHz with the bandwidth of 400 MHz, ensuring that ODMR can be observed under external magnetic fields up to 100 G without the need of adjustment of the resonance frequency. It is also spatially uniform within the 1-mm-diameter center hole, enabling the magnetic-field imaging in the wide spatial range. These features facilitate the experiments on quantum sensing and imaging using NV centers at room temperature.
- 9top 0.7%
A virtual instrument to standardise the calibration of atomic force microscope cantilevers
John E. Sader, Riccardo Borgani, Christopher T. Gibson, David B. Haviland, Michael J. Higgins and 10 more
155 citationsOpen accessdoi:10.1063/1.4962866OpenAlex
Show abstractHide abstract
Atomic force microscope (AFM) users often calibrate the spring constants of cantilevers using functionality built into individual instruments. This calibration is performed without reference to a global standard, hindering the robust comparison of force measurements reported by different laboratories. Here, we describe a virtual instrument (an internet-based initiative) whereby users from all laboratories can instantly and quantitatively compare their calibration measurements to those of others-standardising AFM force measurements-and simultaneously enabling non-invasive calibration of AFM cantilevers of any geometry. This global calibration initiative requires no additional instrumentation or data processing on the part of the user. It utilises a single website where users upload currently available data. A proof-of-principle demonstration of this initiative is presented using measured data from five independent laboratories across three countries, which also allows for an assessment of current calibration.
- 10top 0.8%
The upgraded Large Plasma Device, a machine for studying frontier basic plasma physics
Walter Gekelman, Patrick Pribyl, Z. Lucky, M. Drandell, David Leneman and 8 more
145 citationsdoi:10.1063/1.4941079OpenAlex
Show abstractHide abstract
In 1991 a manuscript describing an instrument for studying magnetized plasmas was published in this journal. The Large Plasma Device (LAPD) was upgraded in 2001 and has become a national user facility for the study of basic plasma physics. The upgrade as well as diagnostics introduced since then has significantly changed the capabilities of the device. All references to the machine still quote the original RSI paper, which at this time is not appropriate. In this work, the properties of the updated LAPD are presented. The strategy of the machine construction, the available diagnostics, the parameters available for experiments, as well as illustrations of several experiments are presented here.
- 11top 0.8%
Opto-electro-modulated transient photovoltage and photocurrent system for investigation of charge transport and recombination in solar cells
Jiangjian Shi, Dongmei Li, Yanhong Luo, Huijue Wu, Qingbo Meng
143 citationsdoi:10.1063/1.4972104OpenAlex
Show abstractHide abstract
An opto-electro-modulated transient photovoltage/photocurrent system has been developed to probe microscopic charge processes of a solar cell in its adjustable operating conditions. The reliability of this system is carefully determined by electric circuit simulations and experimental measurements. Using this system, the charge transport, recombination and storage properties of a conventional multicrystalline silicon solar cell under different steady-state bias voltages, and light illumination intensities are investigated. This system has also been applied to study the influence of the hole transport material layer on charge extraction and the microscopic charge processes behind the widely considered photoelectric hysteresis in perovskite solar cells.
- 12top 0.9%
A one-piece 3D printed flexure translation stage for open-source microscopy
James P. Sharkey, D. C. W. Foo, Alexandre Kabla, Jeremy J. Baumberg, Richard W Bowman
141 citationsOpen access (CC-BY)doi:10.1063/1.4941068OpenAlex
Show abstractHide abstract
Open source hardware has the potential to revolutionise the way we build scientific instruments; with the advent of readily available 3D printers, mechanical designs can now be shared, improved, and replicated faster and more easily than ever before. However, printed parts are typically plastic and often perform poorly compared to traditionally machined mechanisms. We have overcome many of the limitations of 3D printed mechanisms by exploiting the compliance of the plastic to produce a monolithic 3D printed flexure translation stage, capable of sub-micron-scale motion over a range of 8 × 8 × 4 mm. This requires minimal post-print clean-up and can be automated with readily available stepper motors. The resulting plastic composite structure is very stiff and exhibits remarkably low drift, moving less than 20 μm over the course of a week, without temperature stabilisation. This enables us to construct a miniature microscope with excellent mechanical stability, perfect for time-lapse measurements in situ in an incubator or fume hood. The ease of manufacture lends itself to use in…
- 13top 1%
Invited Review Article: “Hands-on” laser-driven ion acceleration: A primer for laser-driven source development and potential applications
J. Schreiber, Paul R. Bolton, Katia Parodi
134 citationsOpen access (CC-BY)doi:10.1063/1.4959198OpenAlex
Show abstractHide abstract
An overview of progress and typical yields from intense laser-plasma acceleration of ions is presented. The evolution of laser-driven ion acceleration at relativistic intensities ushers prospects for improved functionality and diverse applications which can represent a varied assortment of ion beam requirements. This mandates the development of the integrated laser-driven ion accelerator system, the multiple components of which are described. Relevant high field laser-plasma science and design of controlled optimum pulsed laser irradiation on target are dominant single shot (pulse) considerations with aspects that are appropriate to the emerging petawatt era. The pulse energy scaling of maximum ion energies and typical differential spectra obtained over the past two decades provide guidance for continued advancement of laser-driven energetic ion sources and their meaningful applications.
- 14top 1.1%
Plasmakristall-4: New complex (dusty) plasma laboratory on board the International Space Station
Mikhail Pustylnik, M. A. Fink, Vladimir Yu. Nosenko, T. Antonova, Tanja C. Hagl and 23 more
133 citationsdoi:10.1063/1.4962696OpenAlex
Show abstractHide abstract
New complex-plasma facility, Plasmakristall-4 (PK-4), has been recently commissioned on board the International Space Station. In complex plasmas, the subsystem of μm-sized microparticles immersed in low-pressure weakly ionized gas-discharge plasmas becomes strongly coupled due to the high (103–104 e) electric charge on the microparticle surface. The microparticle subsystem of complex plasmas is available for the observation at the kinetic level, which makes complex plasmas appropriate for particle-resolved modeling of classical condensed matter phenomena. The main purpose of PK-4 is the investigation of flowing complex plasmas. To generate plasma, PK-4 makes use of a classical dc discharge in a glass tube, whose polarity can be switched with the frequency of the order of 100 Hz. This frequency is high enough not to be felt by the relatively heavy microparticles. The duty cycle of the polarity switching can be also varied allowing to vary the drift velocity of the microparticles and (when necessary) to trap them. The facility is equipped with two videocameras and illumination laser…
- 15top 1.1%
A storage ring experiment to detect a proton electric dipole moment
V. Anastassopoulos, Serge N. Andrianov, Richard A. Baartman, S. Baeßler, Mei Bai and 25 more
129 citationsOpen access (CC-BY)doi:10.1063/1.4967465OpenAlex
Show abstractHide abstract
A new experiment is described to detect a permanent electric dipole moment of the proton with a sensitivity of 10−29 e ⋅ cm by using polarized “magic” momentum 0.7 GeV/c protons in an all-electric storage ring. Systematic errors relevant to the experiment are discussed and techniques to address them are presented. The measurement is sensitive to new physics beyond the standard model at the scale of 3000 TeV.
- 16top 1.2%
A combined segmented anode gas ionization chamber and time-of-flight detector for heavy ion elastic recoil detection analysis
Petter Ström, Per Petersson, Marek Rubel, Göran Possnert
125 citationsOpen access (OTHER-OA)doi:10.1063/1.4963709OpenAlex
Show abstractHide abstract
A dedicated detector system for heavy ion elastic recoil detection analysis at the Tandem Laboratory of Uppsala University is presented. Benefits of combining a time-of-flight measurement with a segmented anode gas ionization chamber are demonstrated. The capability of ion species identification is improved with the present system, compared to that obtained when using a single solid state silicon detector for the full ion energy signal. The system enables separation of light elements, up to Neon, based on atomic number while signals from heavy elements such as molybdenum and tungsten are separated based on mass, to a sample depth on the order of 1 μm. The performance of the system is discussed and a selection of material analysis applications is given. Plasma-facing materials from fusion experiments, in particular metal mirrors, are used as a main example for the discussion. Marker experiments using nitrogen-15 or oxygen-18 are specific cases for which the described improved species separation and sensitivity are required. Resilience to radiation damage and significantly improved…
- 17top 1.3%
The Thomson scattering system at Wendelstein 7-X
Ekkehard Pasch, M. Beurskens, S. Bozhenkov, G. Fuchert, Jens P Knauer and 2 more
122 citationsOpen access (OTHER-OA)doi:10.1063/1.4962248OpenAlex
Show abstractHide abstract
This paper describes the design of the Thomson scattering system at the Wendelstein 7-X stellarator. For the first operation campaign we installed a 10 spatial channel system to cover a radial half profile of the plasma cross section. The start-up system is based on one Nd:YAG laser with 10 Hz repetition frequency, one observation optics, five fiber bundles with one delay line each, and five interference filter polychromators with five spectral channels and silicon avalanche diodes as detectors. High dynamic range analog to digital converters with 14 bit, 1 GS/s are used to digitize the signals. The spectral calibration of the system was done using a pulsed super continuum laser together with a monochromator. For density calibration we used Raman scattering in nitrogen gas. Peaked temperature profiles and flat density profiles are observed in helium and hydrogen discharges.
- 18top 1.4%
Scanning SQUID susceptometers with sub-micron spatial resolution
John R. Kirtley, Lisa Paulius, Aaron Rosenberg, Johanna C. Palmstrom, Connor M. Holland and 10 more
120 citationsOpen accessdoi:10.1063/1.4961982OpenAlex
Show abstractHide abstract
Superconducting QUantum Interference Device (SQUID) microscopy has excellent magnetic field sensitivity, but suffers from modest spatial resolution when compared with other scanning probes. This spatial resolution is determined by both the size of the field sensitive area and the spacing between this area and the sample surface. In this paper we describe scanning SQUID susceptometers that achieve sub-micron spatial resolution while retaining a white noise floor flux sensitivity of ≈2μΦ0/Hz1/2. This high spatial resolution is accomplished by deep sub-micron feature sizes, well shielded pickup loops fabricated using a planarized process, and a deep etch step that minimizes the spacing between the sample surface and the SQUID pickup loop. We describe the design, modeling, fabrication, and testing of these sensors. Although sub-micron spatial resolution has been achieved previously in scanning SQUID sensors, our sensors not only achieve high spatial resolution but also have integrated modulation coils for flux feedback, integrated field coils for susceptibility measurements, and batch…
- 19top 1.4%
Electrostatic energy harvesting device with dual resonant structure for wideband random vibration sources at low frequency
Yulong Zhang, Tianyang Wang, Ai Zhang, Zhuoteng Peng, Dan Luo and 2 more
111 citationsdoi:10.1063/1.4968811OpenAlex
Show abstractHide abstract
In this paper, we present design and test of a broadband electrostatic energy harvester with a dual resonant structure, which consists of two cantilever-mass subsystems each with a mass attached at the free edge of a cantilever. Comparing to traditional devices with single resonant frequency, the proposed device with dual resonant structure can resonate at two frequencies. Furthermore, when one of the cantilever-masses is oscillating at resonance, the vibration amplitude is large enough to make it collide with the other mass, which provides strong mechanical coupling between the two subsystems. Therefore, this device can harvest a decent power output from vibration sources at a broad frequency range. During the measurement, continuous power output up to 6.2-9.8 μW can be achieved under external vibration amplitude of 9.3 m/s2 at a frequency range from 36.3 Hz to 48.3 Hz, which means the bandwidth of the device is about 30% of the central frequency. The broad bandwidth of the device provides a promising application for energy harvesting from the scenarios with random vibration…
- 20top 1.5%
Towards 10 meV resolution: The design of an ultrahigh resolution soft X-ray RIXS spectrometer
Joseph Dvorak, Ignace Jarrige, Valentina Bisogni, Scott Coburn, William Leonhardt
107 citationsOpen accessdoi:10.1063/1.4964847OpenAlex
Show abstractHide abstract
We present the optical design of the Centurion soft X-ray resonant inelastic X-ray scattering (RIXS) spectrometer to be located on the SIX beamline at NSLS-II. The spectrometer is designed to reach a resolving power of 100 000 at 1000 eV at its best resolution. It is also designed to have continuously variable 2θ motion over a range of 112° using a custom triple rotating flange. We have analyzed several possible spectrometer designs capable of reaching the target resolution. After careful analysis, we have adopted a Hettrick-Underwood spectrometer design, with an additional plane mirror to maintain a fixed direction for the outgoing beam. The spectrometer can cancel defocus and coma aberrations at all energies, has an erect focal plane, and minimizes mechanical motions of the detector. When the beamline resolution is accounted for, the net spectral resolution will be 14 meV at 1000 eV. This will open up many low energy excitations to study and will expand greatly the power of soft X-ray RIXS.
- 21top 1.6%
Upgrade of Langmuir probe diagnostic in ITER-like tungsten mono-block divertor on experimental advanced superconducting tokamak
J.C. Xu, Longjie Wang, Guosheng Xu, Guang–Nan Luo, Damao Yao and 14 more
102 citationsdoi:10.1063/1.4960181OpenAlex
Show abstractHide abstract
In order to withstand rapid increase in particle and power impact onto the divertor and demonstrate the feasibility of the ITER design under long pulse operation, the upper divertor of the EAST tokamak has been upgraded to actively water-cooled, ITER-like tungsten mono-block structure since the 2014 campaign, which is the first attempt for ITER on the tokamak devices. Therefore, a new divertor Langmuir probe diagnostic system (DivLP) was designed and successfully upgraded on the tungsten divertor to obtain the plasma parameters in the divertor region such as electron temperature, electron density, particle and heat fluxes. More specifically, two identical triple probe arrays have been installed at two ports of different toroidal positions (112.5-deg separated toroidally), which can provide fundamental data to study the toroidal asymmetry of divertor power deposition and related 3-dimension (3D) physics, as induced by resonant magnetic perturbations, lower hybrid wave, and so on. The shape of graphite tip and fixed structure of the probe are designed according to the structure of the…
- 22top 1.6%
The cryogenic storage ring CSR
R. von Hahn, A. Becker, F. Berg, K. Blaum, C. Breitenfeldt and 25 more
98 citationsOpen accessdoi:10.1063/1.4953888OpenAlex
Show abstractHide abstract
An electrostatic cryogenic storage ring, CSR, for beams of anions and cations with up to 300 keV kinetic energy per unit charge has been designed, constructed, and put into operation. With a circumference of 35 m, the ion-beam vacuum chambers and all beam optics are in a cryostat and cooled by a closed-cycle liquid helium system. At temperatures as low as (5.5 ± 1) K inside the ring, storage time constants of several minutes up to almost an hour were observed for atomic and molecular, anion and cation beams at an energy of 60 keV. The ion-beam intensity, energy-dependent closed-orbit shifts (dispersion), and the focusing properties of the machine were studied by a system of capacitive pickups. The Schottky-noise spectrum of the stored ions revealed a broadening of the momentum distribution on a time scale of 1000 s. Photodetachment of stored anions was used in the beam lifetime measurements. The detachment rate by anion collisions with residual-gas molecules was found to be extremely low. A residual-gas density below 140 cm(-3) is derived, equivalent to a room-temperature pressure…
- 23top 1.7%
Generation of pressures over 40 GPa using Kawai-type multi-anvil press with tungsten carbide anvils
Takayuki Ishii, Lanlan Shi, Rong Huang, Noriyoshi Tsujino, Dmitrii Druzhbin and 10 more
98 citationsOpen accessdoi:10.1063/1.4941716OpenAlex
Show abstractHide abstract
We have generated over 40 GPa pressures, namely, 43 and 44 GPa, at ambient temperature and 2000 K, respectively, using Kawai-type multi-anvil presses (KMAP) with tungsten carbide anvils for the first time. These high-pressure generations were achieved by combining the following pressure-generation techniques: (1) precisely aligned guide block systems, (2) high hardness of tungsten carbide, (3) tapering of second-stage anvil faces, (4) materials with high bulk modulus in a high-pressure cell, and (5) high heating efficiency.
- 24top 1.8%
Atmospheric pressure X-ray photoelectron spectroscopy apparatus: Bridging the pressure gap
Juan‐Jesús Velasco‐Vélez, Verena Streibel, Michael Hävecker, Ruizhi Wang, Alba Centeno and 10 more
96 citationsOpen access (OTHER-OA)doi:10.1063/1.4951724OpenAlex
Show abstractHide abstract
One of the main goals in catalysis is the characterization of solid/gas interfaces in a reaction environment. The electronic structure and chemical composition of surfaces become heavily influenced by the surrounding environment. However, the lack of surface sensitive techniques that are able to monitor these modifications under high pressure conditions hinders the understanding of such processes. This limitation is known throughout the community as the "pressure gap." We have developed a novel experimental setup that provides chemical information on a molecular level under atmospheric pressure and in presence of reactive gases and at elevated temperatures. This approach is based on separating the vacuum environment from the high-pressure environment by a silicon nitride grid-that contains an array of micrometer-sized holes-coated with a bilayer of graphene. Using this configuration, we have investigated the local electronic structure of catalysts by means of photoelectron spectroscopy and in presence of gases at 1 atm. The reaction products were monitored online by mass…
- 25top 1.9%
High-resolution three-dimensional spin- and angle-resolved photoelectron spectrometer using vacuum ultraviolet laser light
Koichiro Yaji, Ayumi Harasawa, Kenta Kuroda, Sogen Toyohisa, Mitsuhiro Nakayama and 6 more
95 citationsOpen accessdoi:10.1063/1.4948738OpenAlex
Show abstractHide abstract
We describe a spin- and angle-resolved photoelectron spectroscopy (SARPES) apparatus with a vacuum-ultraviolet (VUV) laser (hν = 6.994 eV) developed at the Laser and Synchrotron Research Center at the Institute for Solid State Physics, The University of Tokyo. The spectrometer consists of a hemispherical photoelectron analyzer equipped with an electron deflector function and twin very-low-energy-electron-diffraction-type spin detectors, which allows us to analyze the spin vector of a photoelectron three-dimensionally with both high energy and angular resolutions. The combination of the high-performance spectrometer and the high-photon-flux VUV laser can achieve an energy resolution of 1.7 meV for SARPES. We demonstrate that the present laser-SARPES machine realizes a quick SARPES on the spin-split band structure of a Bi(111) film even with 7 meV energy and 0.7(∘) angular resolutions along the entrance-slit direction. This laser-SARPES machine is applicable to the investigation of spin-dependent electronic states on an energy scale of a few meV.
- 26top 1.9%
High vacuum tip-enhanced Raman spectroscope based on a scanning tunneling microscope
Yurui Fang, Zhenglong Zhang, Mengtao Sun
92 citationsdoi:10.1063/1.4943291OpenAlex
Show abstractHide abstract
In this paper, we present the construction of a high-vacuum tip-enhanced Raman spectroscopy (HV-TERS) system that allows in situ sample preparation and measurement. A detailed description of the prototype instrument is presented with experimental validation of its use and novel ex situ experimental results using the HV-TERS system. The HV-TERS system includes three chambers held under a 10(-7) Pa vacuum. The three chambers are an analysis chamber, a sample preparation chamber, and a fast loading chamber. The analysis chamber is the core chamber and contains a scanning tunneling microscope (STM) and a Raman detector coupled with a 50 × 0.5 numerical aperture objective. The sample preparation chamber is used to produce single-crystalline metal and sub-monolayer molecular films by molecular beam epitaxy. The fast loading chamber allows ex situ preparation of samples for HV-TERS analysis. Atomic resolution can be achieved by the STM on highly ordered pyrolytic graphite. We demonstrate the measurement of localized temperature using the Stokes and anti-Stokes TERS signals from a monolayer…
- 27top 2%
Design and performance of a compact scanning transmission X-ray microscope at the Photon Factory
Yasuo Takeichi, Nobuhito Inami, Hiroki Suga, Chihiro Miyamoto, Tetsuro Ueno and 3 more
92 citationsdoi:10.1063/1.4940409OpenAlex
Show abstractHide abstract
We present a new compact instrument designed for scanning transmission X-ray microscopy. It has piezo-driven linear stages, making it small and light. Optical components from the virtual source point to the detector are located on a single optical table, resulting in a portable instrument that can be operated at a general-purpose spectroscopy beamline without requiring any major reconstruction. Careful consideration has been given to solving the vibration problem common to high-resolution microscopy, so as not to affect the spatial resolution determined by the Fresnel zone plate. Results on bacteriogenic iron oxides, single particle aerosols, and rare-earth permanent magnets are presented as examples of its performance under diverse applications.
- 28top 2.1%
The Advanced LIGO photon calibrators
S. Karki, D. Tuyenbayev, S. Kandhasamy, B. P. Abbott, T. D. Abbott and 23 more
91 citationsOpen accessdoi:10.1063/1.4967303OpenAlex
Show abstractHide abstract
The two interferometers of the Laser Interferometry Gravitational-wave Observatory (LIGO) recently detected gravitational waves from the mergers of binary black hole systems. Accurate calibration of the output of these detectors was crucial for the observation of these events and the extraction of parameters of the sources. The principal tools used to calibrate the responses of the second-generation (Advanced) LIGO detectors to gravitational waves are systems based on radiation pressure and referred to as photon calibrators. These systems, which were completely redesigned for Advanced LIGO, include several significant upgrades that enable them to meet the calibration requirements of second-generation gravitational wave detectors in the new era of gravitational-wave astronomy. We report on the design, implementation, and operation of these Advanced LIGO photon calibrators that are currently providing fiducial displacements on the order of 10−18m/Hz with accuracy and precision of better than 1%.
- 29top 2.1%
Femtosecond time-resolved impulsive stimulated Raman spectroscopy using sub-7-fs pulses: Apparatus and applications
Hikaru Kuramochi, Satoshi Takeuchi, Tahei Tahara
91 citationsdoi:10.1063/1.4945259OpenAlex
Show abstractHide abstract
We describe details of the setup for time-resolved impulsive stimulated Raman spectroscopy (TR-ISRS). In this method, snapshot molecular vibrational spectra of the photoreaction transients are captured via time-domain Raman probing using ultrashort pulses. Our instrument features transform-limited sub-7-fs pulses to impulsively excite and probe coherent nuclear wavepacket motions, allowing us to observe vibrational fingerprints of transient species from the terahertz to 3000-cm(-1) region with high sensitivity. Key optical components for the best spectroscopic performance are discussed. The TR-ISRS measurements for the excited states of diphenylacetylene in cyclohexane are demonstrated, highlighting the capability of our setup to track femtosecond dynamics of all the Raman-active fundamental molecular vibrations.
- 30top 2.2%
BabyMEG: A whole-head pediatric magnetoencephalography system for human brain development research
Yoshio C Okada, Matti Hämäläinen, Kevin Pratt, Anthony Mascarenas, Paul C. Miller and 14 more
89 citationsdoi:10.1063/1.4962020OpenAlex
Show abstractHide abstract
We developed a 375-channel, whole-head magnetoencephalography (MEG) system ("BabyMEG") for studying the electrophysiological development of human brain during the first years of life. The helmet accommodates heads up to 95% of 36-month old boys in the USA. The unique two-layer sensor array consists of: (1) 270 magnetometers (10 mm diameter, ∼15 mm coil-to-coil spacing) in the inner layer, (2) thirty-five three-axis magnetometers (20 mm × 20 mm) in the outer layer 4 cm away from the inner layer. Additionally, there are three three-axis reference magnetometers. With the help of a remotely operated position adjustment mechanism, the sensor array can be positioned to provide a uniform short spacing (mean 8.5 mm) between the sensor array and room temperature surface of the dewar. The sensors are connected to superconducting quantum interference devices (SQUIDs) operating at 4.2 K with median sensitivity levels of 7.5 fT/√Hz for the inner and 4 fT/√Hz for the outer layer sensors. SQUID outputs are digitized by a 24-bit acquisition system. A closed-cycle helium recycler provides…
- 31top 2.3%
Tomography and imaging at the PSICHE beam line of the SOLEIL synchrotron
A. King, Nicolas Guignot, P. Zerbino, E. Boulard, Kewin Desjardins and 11 more
89 citationsdoi:10.1063/1.4961365OpenAlex
Show abstractHide abstract
PSICHE (Pressure, Structure and Imaging by Contrast at High Energy) is the high-energy beam line of the SOLEIL synchrotron. The beam line is designed to study samples at extreme pressures, using diffraction, and to perform imaging and tomography for materials science and other diverse applications. This paper presents the tomograph and the use of the beam line for imaging, with emphasis on developments made with respect to existing instruments. Of particular note are the high load capacity rotation stage with free central aperture for installing large or complex samples and sample environments, x-ray mirror and filter optics for pink beam imaging, and multiple options for combining imaging and diffraction measurement. We describe how x-ray imaging techniques have been integrated into high-pressure experiments. The design and the specifications of the beam line are described, and several case studies drawn from the first user experiments are presented.
- 32top 2.4%
Laboratory von Hámos X-ray spectroscopy for routine sample characterization
Zoltán Németh, Jakub Szlachetko, Éva G. Bajnóczi, György Vankó
87 citationsOpen accessdoi:10.1063/1.4964098OpenAlex
Show abstractHide abstract
High energy resolution, hard X-ray spectroscopies are powerful element selective probes of the electronic and local structure of matter, with diverse applications in chemistry, physics, biology, and materials science. The routine application of these techniques is hindered by the complicated and slow access to synchrotron radiation facilities. Here we propose a new, economic, easily operated laboratory high resolution von Hámos type X-ray spectrometer, which offers rapid transmission experiments for X-ray absorption and is also capable of recording X-ray emission spectra. The use of a cylindrical analyzer crystal and a position sensitive detector enabled us to build a robust, flexible setup with low operational costs, while delivering synchrotron grade signal to noise measurements in reasonable acquisition times. We demonstrate the proof of principle and give examples for both measurement types. Finally, tracking of a several day long chemical transformation, a case better suited for laboratory than synchrotron investigation, is also presented.
- 33top 2.4%
The cold neutron chopper spectrometer at the Spallation Neutron Source—A review of the first 8 years of operation
Georg Ehlers, Andrey A. Podlesnyak, Alexander I. Kolesnikov
86 citationsOpen accessdoi:10.1063/1.4962024OpenAlex
Show abstractHide abstract
The first eight years of operation of the Cold Neutron Chopper Spectrometer (CNCS) at the Spallation Neutron Source in Oak Ridge is being reviewed. The instrument has been part of the facility user program since 2009, and more than 250 individual user experiments have been performed to date. CNCS is an extremely powerful and versatile instrument and offers leading edge performance in terms of beam intensity, energy resolution, and flexibility to trade one for another. Experiments are being routinely performed with the sample at extreme conditions: T ≲ 0.05 K, p ≳ 2 GPa, and B = 8 T can be achieved individually or in combination. In particular, CNCS is in a position to advance the state of the art with inelastic neutron scattering under pressure, and some of the recent accomplishments in this area will be presented in more detail.
- 34top 2.5%
Comparison measurements of low-pressure between a laser refractometer and ultrasonic manometer
Patrick F. Egan, Jack A. Stone, Jacob E. Ricker, Jay H. Hendricks
86 citationsOpen accessdoi:10.1063/1.4949504OpenAlex
Show abstractHide abstract
We have developed a new low-pressure sensor which is based on the measurement of (nitrogen) gas refractivity inside a Fabry-Perot cavity. We compare pressure determinations via this laser refractometer to that of well-established ultrasonic manometers throughout the range 100 Pa to 180 000 Pa. The refractometer demonstrates 10(-6) ⋅ p reproducibility for p > 100 Pa, and this precision outperforms a manometer. We also claim the refractometer has an expanded uncertainty of U(pFP) = [(2.0 mPa)(2) + (8.8 × 10(-6) ⋅ p)(2)](1/2), as realized through the properties of nitrogen gas; we argue that a transfer of the pascal to p < 1 kPa using a laser refractometer is more accurate than the current primary realization.
- 35top 2.6%
Invited Article: A precise instrument to determine the Planck constant, and the future kilogram
Darine Haddad, Frank C. Seifert, Leon Chao, Shisong Li, David B. Newell and 3 more
84 citationsOpen access (CC-BY)doi:10.1063/1.4953825OpenAlex
Show abstractHide abstract
A precise instrument, called a watt balance, compares mechanical power measured in terms of the meter, the second, and the kilogram to electrical power measured in terms of the volt and the ohm. A direct link between mechanical action and the Planck constant is established by the practical realization of the electrical units derived from the Josephson and the quantum Hall effects. We describe in this paper the fourth-generation watt balance at the National Institute of Standards and Technology (NIST), and report our initial determination of the Planck constant obtained from data taken in late 2015 and the beginning of 2016. A comprehensive analysis of the data and the associated uncertainties led to the SI value of the Planck constant, h = 6.626 069 83(22) × 10(-34) J s. The relative standard uncertainty associated with this result is 34 × 10(-9).
- 36top 2.7%
Improved edge charge exchange recombination spectroscopy in DIII-D
C. Chrystal, Keith H. Burrell, B. A. Grierson, S. R. Haskey, Richard J. Groebner and 2 more
79 citationsdoi:10.1063/1.4958915OpenAlex
Show abstractHide abstract
The charge exchange recombination spectroscopy diagnostic on the DIII-D tokamak has been upgraded with the addition of more high radial resolution view chords near the edge of the plasma (r/a > 0.8). The additional views are diagnosed with the same number of spectrometers by placing fiber optics side-by-side at the spectrometer entrance with a precise separation that avoids wavelength shifted crosstalk without the use of bandpass filters. The new views improve measurement of edge impurity parameters in steep gradient, H-mode plasmas with many different shapes. The number of edge view chords with 8 mm radial separation has increased from 16 to 38. New fused silica fibers have improved light throughput and clarify the observation of non-Gaussian spectra that suggest the ion distribution function can be non-Maxwellian in low collisionality plasmas.
- 37top 2.7%
Cryogenic setup for trapped ion quantum computing
M. F. Brandl, M. W. van Mourik, L. Postler, A. Nolf, K. Lakhmanskiy and 13 more
77 citationsOpen accessdoi:10.1063/1.4966970OpenAlex
Show abstractHide abstract
We report on the design of a cryogenic setup for trapped ion quantum computing containing a segmented surface electrode trap. The heat shield of our cryostat is designed to attenuate alternating magnetic field noise, resulting in 120 dB reduction of 50 Hz noise along the magnetic field axis. We combine this efficient magnetic shielding with high optical access required for single ion addressing as well as for efficient state detection by placing two lenses each with numerical aperture 0.23 inside the inner heat shield. The cryostat design incorporates vibration isolation to avoid decoherence of optical qubits due to the motion of the cryostat. We measure vibrations of the cryostat of less than ±20 nm over 2 s. In addition to the cryogenic apparatus, we describe the setup required for an operation with 40Ca+ and 88Sr+ ions. The instability of the laser manipulating the optical qubits in 40Ca+ is characterized by yielding a minimum of its Allan deviation of 2.4 ⋅ 10−15 at 0.33 s. To evaluate the performance of the apparatus, we trapped 40Ca+ ions, obtaining a heating rate of 2.14(16)…
- 38top 2.8%
Ultrafast time measurements by time-correlated single photon counting coupled with superconducting single photon detector
Vladislav I. Shcheslavskiy, Pavel Morozov, Alexander V. Divochiy, Yu. B. Vakhtomin, К. В. Смирнов and 1 more
77 citationsdoi:10.1063/1.4948920OpenAlex
Show abstractHide abstract
Time resolution is one of the main characteristics of the single photon detectors besides quantum efficiency and dark count rate. We demonstrate here an ultrafast time-correlated single photon counting (TCSPC) setup consisting of a newly developed single photon counting board SPC-150NX and a superconducting NbN single photon detector with a sensitive area of 7 × 7 μm. The combination delivers a record instrument response function with a full width at half maximum of 17.8 ps and system quantum efficiency ∼15% at wavelength of 1560 nm. A calculation of the root mean square value of the timing jitter for channels with counts more than 1% of the peak value yielded about 7.6 ps. The setup has also good timing stability of the detector-TCSPC board.
- 39top 2.9%
Invited Review Article: Review of post-process optical form metrology for industrial-grade metal additive manufactured parts
Petros Ioannis Stavroulakis, Richard Leach
77 citationsOpen access (CC-BY)doi:10.1063/1.4944983OpenAlex
Show abstractHide abstract
The scope of this review is to investigate the main post-process optical form measurement technologies available in industry today and to determine whether they are applicable to industrial-grade metal additive manufactured parts. An in-depth review of the operation of optical three-dimensional form measurement technologies applicable to metal additive manufacturing is presented, with a focus on their fundamental limitations. Looking into the future, some alternative candidate measurement technologies potentially applicable to metal additive manufacturing will be discussed, which either provide higher accuracy than currently available techniques but lack measurement volume, or inversely, which operate in the appropriate measurement volume but are not currently accurate enough to be used for industrial measurement.
- 40top 2.9%
Time-resolved single-photon detection module based on silicon photomultiplier: A novel building block for time-correlated measurement systems
E. Martinenghi, Laura Di Sieno, Davide Contini, Mirko Sanzaro, Antonio Pifferi and 1 more
76 citationsOpen access (CC-BY)doi:10.1063/1.4954968OpenAlex
Show abstractHide abstract
We present the design and preliminary characterization of the first detection module based on Silicon Photomultiplier (SiPM) tailored for single-photon timing applications. The aim of this work is to demonstrate, thanks to the design of a suitable module, the possibility to easily exploit SiPM in many applications as an interesting detector featuring large active area, similarly to photomultipliers tubes, but keeping the advantages of solid state detectors (high quantum efficiency, low cost, compactness, robustness, low bias voltage, and insensitiveness to magnetic field). The module integrates a cooled SiPM with a total photosensitive area of 1 mm(2) together with the suitable avalanche signal read-out circuit, the signal conditioning, the biasing electronics, and a Peltier cooler driver for thermal stabilization. It is able to extract the single-photon timing information with resolution better than 100 ps full-width at half maximum. We verified the effective stabilization in response to external thermal perturbations, thus proving the complete insensitivity of the module to…
- 41top 3%
Femtosecond broadband fluorescence upconversion spectroscopy: Spectral coverage versus efficiency
Mario Gerecke, Genaro Bierhance, Michael Gutmann, Nikolaus P. Ernsting, Arnulf Rosspeintner
76 citationsOpen accessdoi:10.1063/1.4948932OpenAlex
Show abstractHide abstract
Sum frequency mixing of fluorescence and ∼1300 nm gate pulses, in a thin β-barium borate crystal and non-collinear type II geometry, is quantified as part of a femtosecond fluorimeter [X.-X. Zhang et al., Rev. Sci. Instrum. 82, 063108 (2011)]. For a series of fixed phasematching angles, the upconversion efficiency is measured depending on fluorescence wavelength. Two useful orientations of the crystal are related by rotation around the surface normal. Orientation A has higher efficiency (factor ∼3) compared to B at the cost of some loss of spectral coverage for a given crystal angle. It should be used when subtle changes of an otherwise stationary emission band are to be monitored. With orientation B, the fluorescence range λF > 420-750 nm is covered with a single setting of the crystal and less gate scatter around time zero. The accuracy of determining an instantaneous emission band shape is demonstrated by comparing results from two laboratories.
- 42top 3.1%
An FPGA-based instrumentation platform for use at deep cryogenic temperatures
I. D. Conway Lamb, James Colless, J. M. Hornibrook, Sebastian Pauka, S. J. Waddy and 2 more
76 citationsOpen access (CC-BY)doi:10.1063/1.4939094OpenAlex
Show abstractHide abstract
We describe the operation of a cryogenic instrumentation platform incorporating commercially available field-programmable gate arrays (FPGAs). The functionality of the FPGAs at temperatures approaching 4 K enables signal routing, multiplexing, and complex digital signal processing in close proximity to cooled devices or detectors within the cryostat. The performance of the FPGAs in a cryogenic environment is evaluated, including clock speed, error rates, and power consumption. Although constructed for the purpose of controlling and reading out quantum computing devices with low latency, the instrument is generic enough to be of broad use in a range of cryogenic applications.
- 43top 3.2%
Active stabilization of ion trap radiofrequency potentials
K. G. Johnson, J. David Wong-Campos, Alessandro Restelli, K. A. Landsman, Brian Neyenhuis and 2 more
73 citationsOpen accessdoi:10.1063/1.4948734OpenAlex
Show abstractHide abstract
We actively stabilize the harmonic oscillation frequency of a laser-cooled atomic ion confined in a radiofrequency (rf) Paul trap by sampling and rectifying the high voltage rf applied to the trap electrodes. We are able to stabilize the 1 MHz atomic oscillation frequency to be better than 10 Hz or 10 ppm. This represents a suppression of ambient noise on the rf circuit by 34 dB. This technique could impact the sensitivity of ion trap mass spectrometry and the fidelity of quantum operations in ion trap quantum information applications.
- 44top 3.2%
Advances in x-ray framing cameras at the National Ignition Facility to improve quantitative precision in x-ray imaging
Laura Robin Benedetti, J. P. Holder, Michael P. Perkins, C. G. Brown, C. S. Anderson and 7 more
71 citationsdoi:10.1063/1.4941754OpenAlex
Show abstractHide abstract
We describe an experimental method to measure the gate profile of an x-ray framing camera and to determine several important functional parameters: relative gain (between strips), relative gain droop (within each strip), gate propagation velocity, gate width, and actual inter-strip timing. Several of these parameters cannot be measured accurately by any other technique. This method is then used to document cross talk-induced gain variations and artifacts created by radiation that arrives before the framing camera is actively amplifying x-rays. Electromagnetic cross talk can cause relative gains to vary significantly as inter-strip timing is varied. This imposes a stringent requirement for gain calibration. If radiation arrives before a framing camera is triggered, it can cause an artifact that manifests as a high-intensity, spatially varying background signal. We have developed a device that can be added to the framing camera head to prevent these artifacts.
- 45top 3.3%
Design and analysis of a high-accuracy flexure hinge
Min Liu, Xianmin Zhang, Sergej Fatikow
69 citationsOpen access (CC-BY)doi:10.1063/1.4948924OpenAlex
Show abstractHide abstract
This paper designs and analyzes a new kind of flexure hinge obtained by using a topology optimization approach, namely, a quasi-V-shaped flexure hinge (QVFH). Flexure hinges are formed by three segments: the left and right segments with convex shapes and the middle segment with straight line. According to the results of topology optimization, the curve equations of profiles of the flexure hinges are developed by numerical fitting. The in-plane dimensionless compliance equations of the flexure hinges are derived based on Castigliano's second theorem. The accuracy of rotation, which is denoted by the compliance of the center of rotation that deviates from the midpoint, is derived. The equations for evaluating the maximum stresses are also provided. These dimensionless equations are verified by finite element analysis and experimentation. The analytical results are within 8% uncertainty compared to the finite element analysis results and within 9% uncertainty compared to the experimental measurement data. Compared with the filleted V-shaped flexure hinge, the QVFH has a higher accuracy…
- 46top 3.4%
Temperature measurements during high flux ion beam irradiations
Miguel Luis Crespillo, J. T. Graham, Yanwen Zhang, William J. Weber
69 citationsOpen accessdoi:10.1063/1.4941720OpenAlex
Show abstractHide abstract
A systematic study of the ion beam heating effect was performed in a temperature range of -170 to 900 °C using a 10 MeV Au(3+) ion beam and a Yttria stabilized Zirconia (YSZ) sample at a flux of 5.5 × 10(12) cm(-2) s(-1). Different geometric configurations of beam, sample, thermocouple positioning, and sample holder were compared to understand the heat/charge transport mechanisms responsible for the observed temperature increase. The beam heating exhibited a strong dependence on the background (initial) sample temperature with the largest temperature increases occurring at cryogenic temperatures and decreasing with increasing temperature. Comparison with numerical calculations suggests that the observed heating effect is, in reality, a predominantly electronic effect and the true temperature rise is small. A simple model was developed to explain this electronic effect in terms of an electrostatic potential that forms during ion irradiation. Such an artificial beam heating effect is potentially problematic in thermostated ion irradiation and ion beam analysis apparatus, as the…
- 47top 3.4%
The rheo-Raman microscope: Simultaneous chemical, conformational, mechanical, and microstructural measures of soft materials
Anthony P. Kotula, Matthew W. Meyer, Francesca De Vito, Jan Philip Plog, Angela R. Hight Walker and 1 more
66 citationsdoi:10.1063/1.4963746OpenAlex
Show abstractHide abstract
The design and performance of an instrument capable of simultaneous Raman spectroscopy, rheology, and optical microscopy are described. The instrument couples a Raman spectrometer and optical microscope to a rotational rheometer through an optically transparent base, and the resulting simultaneous measurements are particularly advantageous in situations where flow properties vary due to either chemical or conformational changes in molecular structure, such as in crystallization, melting, gelation, or curing processes. Instrument performance is demonstrated on two material systems that show thermal transitions. First, we perform steady state rotational tests, Raman spectroscopy, and polarized reflection microscopy during a melting transition in a cosmetic emulsion. Second, we perform small amplitude oscillatory shear measurements along with Raman spectroscopy and polarized reflection microscopy during crystallization of a high density polyethylene. The instrument can be applied to study structure-property relationships in a variety of soft materials including thermoset resins, liquid…
- 48top 3.5%
Accurate measurements of cross-plane thermal conductivity of thin films by dual-frequency time-domain thermoreflectance (TDTR)
Puqing Jiang, Bin Huang, Yee Kan Koh
66 citationsOpen accessdoi:10.1063/1.4954969OpenAlex
Show abstractHide abstract
Accurate measurements of the cross-plane thermal conductivity Λcross of a high-thermal-conductivity thin film on a low-thermal-conductivity (Λs) substrate (e.g., Λcross/Λs > 20) are challenging, due to the low thermal resistance of the thin film compared with that of the substrate. In principle, Λcross could be measured by time-domain thermoreflectance (TDTR), using a high modulation frequency fh and a large laser spot size. However, with one TDTR measurement at fh, the uncertainty of the TDTR measurement is usually high due to low sensitivity of TDTR signals to Λcross and high sensitivity to the thickness hAl of Al transducer deposited on the sample for TDTR measurements. We observe that in most TDTR measurements, the sensitivity to hAl only depends weakly on the modulation frequency f. Thus, we performed an additional TDTR measurement at a low modulation frequency f0, such that the sensitivity to hAl is comparable but the sensitivity to Λcross is near zero. We then analyze the ratio of the TDTR signals at fh to that at f0, and thus significantly improve the accuracy of our Λcross…
- 49top 3.6%
Hybrid acoustic energy harvesting using combined electromagnetic and piezoelectric conversion
Farid Ullah Khan, Izhar Izhar
66 citationsdoi:10.1063/1.4941840OpenAlex
Show abstractHide abstract
This paper reports a novel hybrid acoustic energy harvester. The harvester utilizes both the electromagnetic and piezoelectric conversion mechanisms simultaneously to convert the ambient acoustical noise into electrical power for self-powered wireless sensor nodes. The proposed harvester is comprised of a Helmholtz resonator, two magnets mounted on a piezoelectric plate, and a wound coil located under the magnets. The harvester is characterized both under harmonic and real random acoustical excitations. In-lab, under harmonic acoustical excitation at a sound pressure level of 130 dB and frequency of 2.1 kHz, an optimum power of 2.86 μW (at 114 Ω optimum load) is obtained from electromagnetic conversion and 50 μW (at 1000 Ω optimum load) is generated by the piezoelectric harvester's part. Moreover, in real acoustical environment of a domestic electric generator the peak voltages of 40 and 123 mV are produced by the electromagnetic and piezoelectric portions of the acoustic energy harvester.
- 50top 3.7%
Invited Article: High resolution angle resolved photoemission with tabletop 11 eV laser
Yu He, Inna Vishik, Ming Yi, Shuolong Yang, Zhongkai Liu and 10 more
65 citationsOpen accessdoi:10.1063/1.4939759OpenAlex
Show abstractHide abstract
We developed a table-top vacuum ultraviolet (VUV) laser with 113.778 nm wavelength (10.897 eV) and demonstrated its viability as a photon source for high resolution angle-resolved photoemission spectroscopy (ARPES). This sub-nanosecond pulsed VUV laser operates at a repetition rate of 10 MHz, provides a flux of 2 × 10(12) photons/s, and enables photoemission with energy and momentum resolutions better than 2 meV and 0.012 Å(-1), respectively. Space-charge induced energy shifts and spectral broadenings can be reduced below 2 meV. The setup reaches electron momenta up to 1.2 Å(-1), granting full access to the first Brillouin zone of most materials. Control over the linear polarization, repetition rate, and photon flux of the VUV source facilitates ARPES investigations of a broad range of quantum materials, bridging the application gap between contemporary low energy laser-based ARPES and synchrotron-based ARPES. We describe the principles and operational characteristics of this source and showcase its performance for rare earth metal tritellurides, high temperature cuprate…
How to read this list
The cohort is every article, review and book chapter OpenAlex attributes to Review of Scientific Instruments with publication year 2016, excluding retracted works and paratext such as editorials and errata. The top 50 by citation count are listed; the percentile is the rank divided by the cohort size. 50 of the 50 entries have an abstract in OpenAlex. Counts were read on 29 October 2026 and will not be updated on this page, so a quoted rank stays verifiable. Full rules on the methodology page.
Other journals, same idea
Work with these 25 papers in Kahubi
- The papers land in your library with their DOIs
- Ask anything across all of them, with citations
- Draft a literature review from the same sources
Free plan, no card. Your files stay private unless you share them.
Reading several of these?
Kahubi reads papers with you, keeps every citation traceable and drafts with sources you can check. Free plan, no card.