Most-cited articles · 2017
The 50 most-cited articles in Review of Scientific Instruments, 2017
Ranked by OpenAlex citation count on 29 October 2026, out of 931 eligible articles Review of Scientific Instruments published in 2017. Ranks are frozen; this page will not change. Number one, with 358 citations: High-throughput powder diffraction measurement system consisting of multiple MYTHEN detectors at beamline BL02B2 of SPring-8.
- Cohort
- 931 articles
- Listed
- Top 50 (5.4%)
- Open access
- 31 of 50
- Snapshot
- 2026-10-29
The most-cited articles from Review of Scientific Instruments in 2017 are led by instrumentation for synchrotron and X-ray science, including powder diffraction, photoelectron spectroscopy, and resonant inelastic X-ray scattering endstations. The top paper, by Shogo Kawaguchi, Michitaka Takemoto, K. Osaka and colleagues, describes a high-throughput powder diffraction measurement system using multiple MYTHEN detectors at SPring-8 and has 358 citations. Other highly cited works cover acoustic levitation, photoelastic force measurements in granular materials, and time-domain thermoreflectance for anisotropic thermal conductivity.
The list offers a view of the measurement techniques and instruments that drew the most citations among the 931 eligible articles. Readers can use it to identify recurring themes in instrumentation research and to locate the original papers for further detail.
Introduction written from the titles and abstracts on this list. Every figure below is the source.
Ask about these papers
Grounded in this list only, with sources.
- 1top 0.2%
High-throughput powder diffraction measurement system consisting of multiple MYTHEN detectors at beamline BL02B2 of SPring-8
Shogo Kawaguchi, Michitaka Takemoto, K. Osaka, Eiji Nishibori, Chikako Moriyoshi and 3 more
358 citationsOpen access (CC-BY)doi:10.1063/1.4999454OpenAlex
Show abstractHide abstract
In this study, we developed a user-friendly automatic powder diffraction measurement system for Debye–Scherrer geometry using a capillary sample at beamline BL02B2 of SPring-8. The measurement system consists of six one-dimensional solid-state (MYTHEN) detectors, a compact auto-sampler, wide-range temperature control systems, and a gas handling system. This system enables to do the automatic measurement of temperature dependence of the diffraction patterns for multiple samples. We introduced two measurement modes in the MYTHEN system and developed new attachments for the sample environment such as a gas handling system. The measurement modes and the attachments can offer in situ and/or time-resolved measurements in an extended temperature range between 25 K and 1473 K and various gas atmospheres and pressures. The results of the commissioning and performance measurements using reference materials (NIST CeO2 674b and Si 640c), V2O3 and Ti2O3, and a nanoporous coordination polymer are presented.
- 2top 0.3%
TinyLev: A multi-emitter single-axis acoustic levitator
Asier Marzo, A C Barnes, Bruce W. Drinkwater
329 citationsOpen access (CC-BY)doi:10.1063/1.4989995OpenAlex
Show abstractHide abstract
Acoustic levitation has the potential to enable novel studies due to its ability to hold a wide variety of substances against gravity under container-less conditions. It has found application in spectroscopy, chemistry, and the study of organisms in microgravity. Current levitators are constructed using Langevin horns that need to be manufactured to high tolerance with carefully matched resonant frequencies. This resonance condition is hard to maintain as their temperature changes due to transduction heating. In addition, Langevin horns are required to operate at high voltages (>100 V) which may cause problems in challenging experimental environments. Here, we design, build, and evaluate a single-axis levitator based on multiple, low-voltage (ca. 20 V), well-matched, and commercially available ultrasonic transducers. The levitator operates at 40 kHz in air and can trap objects above 2.2 g/cm3 density and 4 mm in diameter whilst consuming 10 W of input power. Levitation of water, fused-silica spheres, small insects, and electronic components is demonstrated. The device is constructed…
- 3top 0.4%
Photoelastic force measurements in granular materials
Karen E. Daniels, Jonathan E. Kollmer, James G. Puckett
207 citationsOpen access (CC-BY)doi:10.1063/1.4983049OpenAlex
Show abstractHide abstract
Photoelastic techniques are used to make both qualitative and quantitative measurements of the forces within idealized granular materials. The method is based on placing a birefringent granular material between a pair of polarizing filters, so that each region of the material rotates the polarization of light according to the amount of local stress. In this review paper, we summarize the past work using the technique, describe the optics underlying the technique, and illustrate how it can be used to quantitatively determine the vector contact forces between particles in a 2D granular system. We provide a description of software resources available to perform this task, as well as key techniques and resources for building an experimental apparatus.
- 4top 0.5%
Time-domain thermoreflectance (TDTR) measurements of anisotropic thermal conductivity using a variable spot size approach
Puqing Jiang, Xin Qian, Ronggui Yang
175 citationsOpen accessdoi:10.1063/1.4991715OpenAlex
Show abstractHide abstract
It is challenging to characterize thermal conductivity of materials with strong anisotropy. In this work, we extend the time-domain thermoreflectance (TDTR) method with a variable spot size approach to simultaneously measure the in-plane (Kr) and the through-plane (Kz) thermal conductivity of materials with strong anisotropy. We first determine Kz from the measurement using a larger spot size, when the heat flow is mainly one-dimensional along the through-plane direction, and the measured signals are only sensitive to Kz. We then extract the in-plane thermal conductivity Kr from a second measurement using the same modulation frequency but with a smaller spot size, when the heat flow becomes three-dimensional, and the signal is sensitive to both Kr and Kz. By choosing the same modulation frequency for the two sets of measurements, we can avoid potential artifacts introduced by the frequency-dependent Kz, which we have found to be non-negligible, especially for some two-dimensional layered materials like MoS2. After careful evaluation of the sensitivity of a series of hypothetical…
- 5top 0.6%
A facility for the analysis of the electronic structures of solids and their surfaces by synchrotron radiation photoelectron spectroscopy
Moritz Hoesch, T. K. Kim, Pavel Dudin, Hongchang Wang, S M Scott and 13 more
152 citationsOpen accessdoi:10.1063/1.4973562OpenAlex
Show abstractHide abstract
A synchrotron radiation beamline in the photon energy range of 18-240 eV and an electron spectroscopy end station have been constructed at the 3 GeV Diamond Light Source storage ring. The instrument features a variable polarisation undulator, a high resolution monochromator, a re-focussing system to form a beam spot of 50 × 50 μm2, and an end station for angle-resolved photoelectron spectroscopy (ARPES) including a 6-degrees-of-freedom cryogenic sample manipulator. The beamline design and its performance allow for a highly productive and precise use of the ARPES technique at an energy resolution of 10-15 meV for fast k-space mapping studies with a photon flux up to 2 ⋅ 1013 ph/s and well below 3 meV for high resolution spectra.
- 6top 0.7%
Invited Review Article: Instrumentation for nuclear magnetic resonance in zero and ultralow magnetic field
Michael C. D. Tayler, Thomas Theis, Tobias F. Sjolander, John W. Blanchard, Arne Kentner and 3 more
138 citationsOpen accessdoi:10.1063/1.5003347OpenAlex
Show abstractHide abstract
We review experimental techniques in our laboratory for nuclear magnetic resonance (NMR) in zero and ultralow magnetic field (below 0.1 μT) where detection is based on a low-cost, non-cryogenic, spin-exchange relaxation free 87Rb atomic magnetometer. The typical sensitivity is 20-30 fT/Hz1/2 for signal frequencies below 1 kHz and NMR linewidths range from Hz all the way down to tens of mHz. These features enable precision measurements of chemically informative nuclear spin-spin couplings as well as nuclear spin precession in ultralow magnetic fields.
- 7top 0.8%
A practical superconducting-microcalorimeter X-ray spectrometer for beamline and laboratory science
William Bertrand Doriese, Peter M. Abbamonte, Bradley K. Alpert, D. A. Bennett, E. V. Denison and 21 more
138 citationsOpen accessdoi:10.1063/1.4983316OpenAlex
Show abstractHide abstract
We describe a series of microcalorimeter X-ray spectrometers designed for a broad suite of measurement applications. The chief advantage of this type of spectrometer is that it can be orders of magnitude more efficient at collecting X-rays than more traditional high-resolution spectrometers that rely on wavelength-dispersive techniques. This advantage is most useful in applications that are traditionally photon-starved and/or involve radiation-sensitive samples. Each energy-dispersive spectrometer is built around an array of several hundred transition-edge sensors (TESs). TESs are superconducting thin films that are biased into their superconducting-to-normal-metal transitions. The spectrometers share a common readout architecture and many design elements, such as a compact, 65 mK detector package, 8-column time-division-multiplexed superconducting quantum-interference device readout, and a liquid-cryogen-free cryogenic system that is a two-stage adiabatic-demagnetization refrigerator backed by a pulse-tube cryocooler. We have adapted this flexible architecture to mate to a variety…
- 8top 0.9%
High-efficiency in situ resonant inelastic x-ray scattering (iRIXS) endstation at the Advanced Light Source
Ruimin Qiao, Qinghao Li, Zengqing Zhuo, Shawn Sallis, Oliver Fuchs and 19 more
137 citationsOpen accessdoi:10.1063/1.4977592OpenAlex
Show abstractHide abstract
An endstation with two high-efficiency soft x-ray spectrographs was developed at Beamline 8.0.1 of the Advanced Light Source, Lawrence Berkeley National Laboratory. The endstation is capable of performing soft x-ray absorption spectroscopy, emission spectroscopy, and, in particular, resonant inelastic soft x-ray scattering (RIXS). Two slit-less variable line-spacing grating spectrographs are installed at different detection geometries. The endstation covers the photon energy range from 80 to 1500 eV. For studying transition-metal oxides, the large detection energy window allows a simultaneous collection of x-ray emission spectra with energies ranging from the O K-edge to the Ni L-edge without moving any mechanical components. The record-high efficiency enables the recording of comprehensive two-dimensional RIXS maps with good statistics within a short acquisition time. By virtue of the large energy window and high throughput of the spectrographs, partial fluorescence yield and inverse partial fluorescence yield signals could be obtained for all transition metal L-edges including Mn.…
- 9top 1%
CAT-ACT—A new highly versatile x-ray spectroscopy beamline for catalysis and radionuclide science at the KIT synchrotron light facility ANKA
Anna Zimina, Kathy Dardenne, Melissa A. Denecke, Dmitry E. Doronkin, E. Huttel and 9 more
135 citationsOpen accessdoi:10.1063/1.4999928OpenAlex
Show abstractHide abstract
CAT-ACT-the hard X-ray beamline for CATalysis and ACTinide/radionuclide research at the KIT synchrotron radiation facility ANKA-is dedicated to X-ray spectroscopy, including "flux hungry" photon-in/photon-out and correlative techniques and combines state-of-the-art optics with a unique infrastructure for radionuclide and catalysis research. Measurements can be performed at photon energies varying between 3.4 keV and 55 keV, thus encompassing the actinide M- and L-edge or potassium K-edge up to the K-edges of the lanthanide series such as cerium. Well-established X-ray absorption fine structure spectroscopy in transmission and fluorescence detection modes is available in combination with high energy-resolution X-ray emission spectroscopy or X-ray diffraction techniques. The modular beamline design with two alternately operated in-line experimental stations enables sufficient flexibility to adapt sample environments and detection systems to many scientific challenges. The ACT experimental station focuses on various aspects of nuclear waste disposal within the mission of the Helmholtz…
- 10top 1.1%
Coincidence velocity map imaging using Tpx3Cam, a time stamping optical camera with 1.5 ns timing resolution
Arthur Zhao, M. van Beuzekom, Bram Bouwens, Д. В. Белов, I. Chakaberia and 7 more
125 citationsOpen accessdoi:10.1063/1.4996888OpenAlex
Show abstractHide abstract
We demonstrate a coincidence velocity map imaging apparatus equipped with a novel time-stamping fast optical camera, Tpx3Cam, whose high sensitivity and nanosecond timing resolution allow for simultaneous position and time-of-flight detection. This single detector design is simple, flexible, and capable of highly differential measurements. We show detailed characterization of the camera and its application in strong field ionization experiments.
- 11top 1.2%
Selective sensitivity in Kerr microscopy
Ivan V. Soldatov, Rudolf Schäfer
114 citationsOpen accessdoi:10.1063/1.4991820OpenAlex
Show abstractHide abstract
A new technique for contrast separation in wide-field magneto-optical Kerr microscopy is introduced. Utilizing the light from eight light emitting diodes, guided to the microscope by glass fibers and being switched synchronously with the camera exposure, domain images with orthogonal in-plane sensitivity can be displayed simultaneously at real-time, and images with pure in-plane or polar contrast can be obtained. The benefit of this new method of contrast separation is demonstrated for Permalloy films, a NdFeB sinter magnet, and a cobalt crystal. Moreover, the new technique is shown to strongly enhance the sensitivity of Kerr microscopy by eliminating parasitic contrast contributions occurring in conventional setups. A doubling of the in-plane domain contrast and a sensitivity to Kerr rotations as low as 0.6 mdeg is demonstrated.
- 12top 1.3%
Invited Review Article: Gas puff imaging diagnostics of edge plasma turbulence in magnetic fusion devices
Stewart J. Zweben, J. L. Terry, Daren P. Stotler, R. J. Maqueda
113 citationsOpen accessdoi:10.1063/1.4981873OpenAlex
Show abstractHide abstract
Gas puff imaging (GPI) is a diagnostic of plasma turbulence which uses a puff of neutral gas at the plasma edge to increase the local visible light emission for improved space-time resolution of plasma fluctuations. This paper reviews gas puff imaging diagnostics of edge plasma turbulence in magnetic fusion research, with a focus on the instrumentation, diagnostic cross-checks, and interpretation issues. The gas puff imaging hardware, optics, and detectors are described for about 10 GPI systems implemented over the past ∼15 years. Comparison of GPI results with other edge turbulence diagnostic results is described, and many common features are observed. Several issues in the interpretation of GPI measurements are discussed, and potential improvements in hardware and modeling are suggested.
- 13top 1.4%
A multi-frequency electrical impedance tomography system for real-time 2D and 3D imaging
Yunjie Yang, Jiabin Jia
107 citationsOpen access (OTHER-OA)doi:10.1063/1.4999359OpenAlex
Show abstractHide abstract
This paper presents the design and evaluation of a configurable, fast multi-frequency Electrical Impedance Tomography (mfEIT) system for real-time 2D and 3D imaging, particularly for biomedical imaging. The system integrates 32 electrode interfaces and the current frequency ranges from 10 kHz to 1 MHz. The system incorporates the following novel features. First, a fully adjustable multi-frequency current source with current monitoring function is designed. Second, a flexible switching scheme is developed for arbitrary sensing configuration and a semi-parallel data acquisition architecture is implemented for high-frame-rate data acquisition. Furthermore, multi-frequency digital quadrature demodulation is accomplished in a high-capacity Field Programmable Gate Array. At last, a 3D imaging software, visual tomography, is developed for real-time 2D and 3D image reconstruction, data analysis, and visualization. The mfEIT system is systematically tested and evaluated from the aspects of signal to noise ratio (SNR), frame rate, and 2D and 3D multi-frequency phantom imaging. The highest SNR…
- 14top 1.6%
The new versatile general purpose surface-muon instrument (GPS) based on silicon photomultipliers for μSR measurements on a continuous-wave beam
Alex Amato, Hubertus Luetkens, Kamil Sedlák, Alexey Stoykov, R. Scheuermann and 3 more
102 citationsOpen accessdoi:10.1063/1.4986045OpenAlex
Show abstractHide abstract
We report on the design and commissioning of a new spectrometer for muon-spin relaxation/rotation studies installed at the Swiss Muon Source (SμS) of the Paul Scherrer Institute (PSI, Switzerland). This new instrument is essentially a new design and replaces the old general-purpose surface-muon (GPS) instrument that has been for long the workhorse of the μSR user facility at PSI. By making use of muon and positron detectors made of plastic scintillators read out by silicon photomultipliers, a time resolution of the complete instrument of about 160 ps (standard deviation) could be achieved. In addition, the absence of light guides, which are needed in traditionally built μSR instrument to deliver the scintillation light to photomultiplier tubes located outside magnetic fields applied, allowed us to design a compact instrument with a detector set covering an increased solid angle compared with the old GPS.
- 15top 1.7%
Modular soft x-ray spectrometer for applications in energy sciences and quantum materials
Yi‐De Chuang, Yu-Cheng Shao, Alejandro Cruz, K. Hanzel, Adam Brown and 18 more
85 citationsOpen access (CC-BY)doi:10.1063/1.4974356OpenAlex
Show abstractHide abstract
Over the past decade, the advances in grating-based soft X-ray spectrometers have revolutionized the soft X-ray spectroscopies in materials research. However, these novel spectrometers are mostly dedicated designs, which cannot be easily adopted for applications with diverging demands. Here we present a versatile spectrometer design concept based on the Hettrick-Underwood optical scheme that uses modular mechanical components. The spectrometer’s optics chamber can be used with gratings operated in either inside or outside orders, and the detector assembly can be reconfigured accordingly. The spectrometer can be designed to have high spectral resolution, exceeding 10 000 resolving power when using small source (∼1μm) and detector pixels (∼5μm) with high line density gratings (∼3000 lines/mm), or high throughput at moderate resolution. We report two such spectrometers with slightly different design goals and optical parameters in this paper. We show that the spectrometer with high throughput and large energy window is particularly useful for studying the sustainable energy materials.…
- 16top 1.8%
A reconfigurable cryogenic platform for the classical control of quantum processors
Harald Homulle, Stefan Visser, Bishnu Patra, Giorgio Ferrari, Enrico Prati and 2 more
84 citationsOpen access (CC-BY)doi:10.1063/1.4979611OpenAlex
Show abstractHide abstract
The implementation of a classical control infrastructure for large-scale quantum computers is challenging due to the need for integration and processing time, which is constrained by coherence time. We propose a cryogenic reconfigurable platform as the heart of the control infrastructure implementing the digital error-correction control loop. The platform is implemented on a field-programmable gate array (FPGA) that supports the functionality required by several qubit technologies and that can operate close to the physical qubits over a temperature range from 4 K to 300 K. This work focuses on the extensive characterization of the electronic platform over this temperature range. All major FPGA building blocks (such as look-up tables (LUTs), carry chains (CARRY4), mixed-mode clock manager (MMCM), phase-locked loop (PLL), block random access memory, and IDELAY2 (programmable delay element)) operate correctly and the logic speed is very stable. The logic speed of LUTs and CARRY4 changes less then 5%, whereas the jitter of MMCM and PLL clock managers is reduced by 20%. The stability is…
- 17top 1.9%
Hardware for dynamic quantum computing
Colm A. Ryan, Blake Johnson, Diego Ristè, Brian Donovan, Thomas Ohki
83 citationsOpen accessdoi:10.1063/1.5006525OpenAlex
Show abstractHide abstract
We describe the hardware, gateware, and software developed at Raytheon BBN Technologies for dynamic quantum information processing experiments on superconducting qubits. In dynamic experiments, real-time qubit state information is fed back or fed forward within a fraction of the qubits' coherence time to dynamically change the implemented sequence. The hardware presented here covers both control and readout of superconducting qubits. For readout, we created a custom signal processing gateware and software stack on commercial hardware to convert pulses in a heterodyne receiver into qubit state assignments with minimal latency, alongside data taking capability. For control, we developed custom hardware with gateware and software for pulse sequencing and steering information distribution that is capable of arbitrary control flow in a fraction of superconducting qubit coherence times. Both readout and control platforms make extensive use of field programmable gate arrays to enable tailored qubit control systems in a reconfigurable fabric suitable for iterative development.
- 18top 2%
Magnetoencephalography with a Cs-based high-sensitivity compact atomic magnetometer
Jingwei Sheng, Shuangai Wan, Yifan Sun, Rongshe Dou, Yuhao Guo and 4 more
81 citationsdoi:10.1063/1.5001730OpenAlex
Show abstractHide abstract
In recent years, substantial progress has been made in developing a new generation of magnetoencephalography (MEG) with a spin-exchange relaxation free (SERF)-based atomic magnetometer (AM). An AM employs alkali atoms to detect weak magnetic fields. A compact AM array with high sensitivity is crucial to the design; however, most proposed compact AMs are potassium (K)- or rubidium (Rb)-based with single beam configurations. In the present study, a pump-probe two beam configuration with a Cesium (Cs)-based AM (Cs-AM) is introduced to detect human neuronal magnetic fields. The length of the vapor cell is 4 mm, which can fully satisfy the need of designing a compact sensor array. Compared with state-of-the-art compact AMs, our new Cs-AM has two advantages. First, it can be operated in a SERF regime, requiring much lower heating temperature, which benefits the sensor with a closer distance to scalp due to ease of thermal insulation and less electric heating noise interference. Second, the two-beam configuration in the design can achieve higher sensitivity. It is free of magnetic…
- 19top 2.1%
Low noise current preamplifier for qPlus sensor deflection signal detection in atomic force microscopy at room and low temperatures
Ferdinand Huber, Franz J. Gießibl
79 citationsdoi:10.1063/1.4993737OpenAlex
Show abstractHide abstract
The resolution of frequency modulation atomic force microscopy is limited by instrumental noise. When using a qPlus sensor, the deflection detector noise is the dominant noise contribution. It can be reduced by improving the preamplifier used to amplify the sensor deflection signal. We present a simple single-stage differential preamplifier which outperforms previous designs known to us by at least a factor of two in the deflection noise density. We show specific versions of this preamplifier to use in ambient conditions, in ultra-high vacuum at room temperature, and at 4.2 K. Furthermore, we compare the thermal peak analysis and the frequency shift noise density method as a means to determine the deflection noise density. We note that this preamplifier can also be used for any current-generating sensors such as other piezoelectric sensors and photodiodes, but, in this paper, we restrict our analysis to qPlus sensors.
- 20top 2.2%
High energy-resolution x-ray spectroscopy at ultra-high dilution with spherically bent crystal analyzers of 0.5 m radius
Mauro Rovezzi, Christophe Lapras, Alain Manceau, Pieter Glatzel, Roberto Verbeni
79 citationsOpen accessdoi:10.1063/1.4974100OpenAlex
Show abstractHide abstract
We present the development, manufacturing, and performance of spherically bent crystal analyzers (SBCAs) of 100 mm diameter and 0.5 m bending radius. The elastic strain in the crystal wafer is partially released by a "strip-bent" method where the crystal wafer is cut into strips prior to the bending and the anodic bonding process. Compared to standard 1 m SBCAs, a gain in intensity is obtained without loss of energy resolution. The gain ranges between 2.5 and 4.5, depending on the experimental conditions and the width of the emission line measured. This reduces the acquisition times required to perform high energy-resolution x-ray absorption and emission spectroscopy on ultra-dilute species, accessing concentrations of the element of interest down to, or below, the ppm (ng/mg) level.
- 21top 2.3%
Simultaneous measurement of temperature, stress, and electric field in GaN HEMTs with micro-Raman spectroscopy
Kevin R. Bagnall, Elizabeth A. Moore, Ştefan C. Bǎdescu, Lenan Zhang, Evelyn N. Wang
78 citationsOpen accessdoi:10.1063/1.5010225OpenAlex
Show abstractHide abstract
As semiconductor devices based on silicon reach their intrinsic material limits, compound semiconductors, such as gallium nitride (GaN), are gaining increasing interest for high performance, solid-state transistor applications. Unfortunately, higher voltage, current, and/or power levels in GaN high electron mobility transistors (HEMTs) often result in elevated device temperatures, degraded performance, and shorter lifetimes. Although micro-Raman spectroscopy has become one of the most popular techniques for measuring localized temperature rise in GaN HEMTs for reliability assessment, decoupling the effects of temperature, mechanical stress, and electric field on the optical phonon frequencies measured by micro-Raman spectroscopy is challenging. In this work, we demonstrate the simultaneous measurement of temperature rise, inverse piezoelectric stress, thermoelastic stress, and vertical electric field via micro-Raman spectroscopy from the shifts of the E2 (high), A1 longitudinal optical (LO), and E2 (low) optical phonon frequencies in wurtzite GaN. We also validate experimentally…
- 22top 2.4%
Wide-aperture aspherical lens for high-resolution terahertz imaging
Nikita V. Chernomyrdin, Maxim E. Frolov, Sergey P. Lebedev, Igor Vladimirovich Reshetov, Igor E Spektor and 7 more
78 citationsdoi:10.1063/1.4973764OpenAlex
Show abstractHide abstract
In this paper, we introduce wide-aperture aspherical lens for high-resolution terahertz (THz) imaging. The lens has been designed and analyzed by numerical methods of geometrical optics and electrodynamics. It has been made of high-density polyethylene by shaping at computer-controlled lathe and characterized using a continuous-wave THz imaging setup based on a backward-wave oscillator and Golay detector. The concept of image contrast has been implemented to estimate image quality. According to the experimental data, the lens allows resolving two points spaced at 0.95λ distance with a contrast of 15%. To highlight high resolution in the THz images, the wide-aperture lens has been employed for studying printed electronic circuit board containing sub-wavelength-scale elements. The observed results justify the high efficiency of the proposed lens design.
- 23top 2.5%
Micrometer-thickness liquid sheet jets flowing in vacuum
Gediminas Galinis, J. Strucka, Jonathan C. T. Barnard, Avi Braun, Roland A. Smith and 1 more
76 citationsdoi:10.1063/1.4990130OpenAlex
Show abstractHide abstract
Thin liquid sheet jet flows in vacuum provide a new platform for performing experiments in the liquid phase, for example X-ray spectroscopy. Micrometer thickness, high stability, and optical flatness are the key characteristics required for successful exploitation of these targets. A novel strategy for generating sheet jets in vacuum is presented in this article. Precision nozzles were designed and fabricated using high resolution (0.2 μm) 2-photon 3D printing and generated 1.49 ± 0.04 μm thickness, stable, and <λ/20-flat jets in isopropanol under normal atmosphere and under vacuum at 5 × 10−1 mbar. The thin sheet technology also holds great promise for advancing the fields of high harmonic generation in liquids, laser acceleration of ions as well as other fields requiring precision and high repetition rate targets.
- 24top 2.6%
Simultaneous measurement of in-plane and through-plane thermal conductivity using beam-offset frequency domain thermoreflectance
David Misha Rodin, Shannon K. Yee
73 citationsdoi:10.1063/1.4973297OpenAlex
Show abstractHide abstract
Transient thermoreflectance (TTR) techniques are ubiquitous methods for measuring thermal conductivity of bulk materials and thin-films. Both through-plane thermal conductivity k⊥ and in-plane thermal conductivity k∥ should be independently measured in transversely anisotropic materials. When these properties are measured using conventional TTR techniques, the accuracy of the k∥ measurement is dependent on the accuracy of measuring k⊥ and vice versa. This is especially problematic for thin-films measurements as uncertainty in k⊥ (∼5%) can propagate and grow for uncertainty in k∥. In this paper, we present a method for the simultaneous measurement of k⊥ and k∥ using beam-offset frequency domain thermoreflectance (FDTR) with robust uncertainty estimation. The conventional diffusive heat transfer solution is analyzed to show that offset and heating frequency can independently control the sensitivity to directional thermal conductivity and extract values for k∥ and k⊥. Numerical uncertainty analyses demonstrate that sweeping both heating frequency and beam offset results in a reduction…
- 25top 2.7%
Invited Review Article: Measurements of the Newtonian constant of gravitation, G
Christian Rothleitner, Stephan Schlamminger
72 citationsOpen access (CC-BY)doi:10.1063/1.4994619OpenAlex
Show abstractHide abstract
By many accounts, the Newtonian constant of gravitation G is the fundamental constant that is most difficult to measure accurately. Over the past three decades, more than a dozen precision measurements of this constant have been performed. However, the scatter of the data points is much larger than the uncertainties assigned to each individual measurement, yielding a Birge ratio of about five. Today, G is known with a relative standard uncertainty of 4.7 × 10−5, which is several orders of magnitudes greater than the relative uncertainties of other fundamental constants. In this article, various methods to measure G are discussed. A large array of different instruments ranging from the simple torsion balance to the sophisticated atom interferometer can be used to determine G. Some instruments, such as the torsion balance can be used in several different ways. In this article, the advantages and disadvantages of different instruments as well as different methods are discussed. A narrative arc from the historical beginnings of the different methods to their modern implementation is…
- 26top 2.8%
Cryogenic photoluminescence imaging system for nanoscale positioning of single quantum emitters
Jin Liu, Marcelo Davanço, Luca Sapienza, Kumarasiri Konthasinghe, José Vinícius de Miranda Cardoso and 3 more
71 citationsOpen accessdoi:10.1063/1.4976578OpenAlex
Show abstractHide abstract
We report a photoluminescence imaging system for locating single quantum emitters with respect to alignment features. Samples are interrogated in a 4 K closed-cycle cryostat by a high numerical aperture (NA = 0.9, 100× magnification) objective that sits within the cryostat, enabling high efficiency collection of emitted photons without image distortions due to the cryostat windows. The locations of single InAs/GaAs quantum dots within a >50 μm × 50 μm field of view are determined with ≈4.5 nm uncertainty (one standard deviation) in a 1 s long acquisition. The uncertainty is determined through a combination of a maximum likelihood estimate for localizing the quantum dot emission, and a cross correlation method for determining the alignment mark center. This location technique can be an important step in the high-throughput creation of nanophotonic devices that rely upon the interaction of highly confined optical modes with single quantum emitters.
- 27top 3%
A brain-controlled lower-limb exoskeleton for human gait training
Dong Liu, Weihai Chen, Zhongcai Pei, Jianhua Wang
70 citationsdoi:10.1063/1.5006461OpenAlex
Show abstractHide abstract
Brain-computer interfaces have been a novel approach to translate human intentions into movement commands in robotic systems. This paper describes an electroencephalogram-based brain-controlled lower-limb exoskeleton for gait training, as a proof of concept towards rehabilitation with human-in-the-loop. Instead of using conventional single electroencephalography correlates, e.g., evoked P300 or spontaneous motor imagery, we propose a novel framework integrated two asynchronous signal modalities, i.e., sensorimotor rhythms (SMRs) and movement-related cortical potentials (MRCPs). We executed experiments in a biologically inspired and customized lower-limb exoskeleton where subjects (N = 6) actively controlled the robot using their brain signals. Each subject performed three consecutive sessions composed of offline training, online visual feedback testing, and online robot-control recordings. Post hoc evaluations were conducted including mental workload assessment, feature analysis, and statistics test. An average robot-control accuracy of 80.16% ± 5.44% was obtained with the SMR-based…
- 28top 3.1%
Analyzing X-ray tomographies of granular packings
Simon Weis, Matthias Schröter
70 citationsOpen accessdoi:10.1063/1.4983051OpenAlex
Show abstractHide abstract
Starting from three-dimensional volume data of a granular packing, as, e.g., obtained by X-ray Computed Tomography, we discuss methods to first detect the individual particles in the sample and then analyze their properties. This analysis includes the pair correlation function, the volume and shape of the Voronoi cells, and the number and type of contacts formed between individual particles. We mainly focus on packings of monodisperse spheres, but we will also comment on other monoschematic particles such as ellipsoids and tetrahedra. This paper is accompanied by a package of free software containing all programs (including source code) and an example three-dimensional dataset which allows the reader to reproduce and modify all examples given.
- 29top 3.2%
A novel THz-band double-beam gyrotron for high-field DNP-NMR spectroscopy
T. Idehara, Mikhail Yu. Glyavin, Alexei N. Kuleshov, Svilen Petrov Sabchevski, Vladimir Manuilov and 3 more
68 citationsdoi:10.1063/1.4997994OpenAlex
Show abstractHide abstract
We present the first experimental results of the study on a novel second harmonic THz-band double-beam gyrotron. The tube has demonstrated a stable single-mode operation with output parameters that are appropriate for the next-generation 1.2 GHz dynamic nuclear polarization-nuclear magnetic resonance spectroscopy. Besides the design mode (TE8,5), a series of other fundamental and second harmonic modes have been excited. This makes the new gyrotron a versatile radiation source, which can be used also in other applications of the high-power science and technologies.
- 30top 3.3%
OMNY PIN—A versatile sample holder for tomographic measurements at room and cryogenic temperatures
Mirko Holler, Jörg Raabe, Roger Albert Wepf, Sarah H. Shahmoradian, Ana Díaz and 4 more
67 citationsOpen access (CC-BY)doi:10.1063/1.4996092OpenAlex
Show abstractHide abstract
Nowadays ptychographic tomography in the hard x-ray regime, i.e., at energies above about 2 keV, is a well-established measurement technique. At the Paul Scherrer Institut, currently two instruments are available: one is measuring at room temperature and atmospheric pressure, and the other, the so-called OMNY (tOMography Nano crYo) instrument, is operating at ultra-high vacuum and offering cryogenic sample temperatures down to 10 K. In this manuscript, we present the sample mounts that were developed for these instruments. Aside from excellent mechanical stability and thermal conductivity, they also offer highly reproducible mounting. Various types were developed for different kinds of samples and are presented in detail, including examples of how specimens can be mounted on these holders. We also show the first hard x-ray ptychographic tomography measurements of high-pressure frozen biological samples, in the present case Chlamydomonas cells, the related sample pins and preparation steps. For completeness, we present accessories such as transportation containers for both room…
- 31top 3.4%
Edge-preserving reconstruction from sparse projections of limited-angle computed tomography using ℓ-regularized gradient prior
Wei Yu, Chengxiang Wang, Min Huang
65 citationsdoi:10.1063/1.4981132OpenAlex
Show abstractHide abstract
Accurate images reconstructed from limited computed tomography (CT) data are desired when reducing the X-ray radiation exposure imposed on patients. The total variation (TV), known as the l1-norm of the image gradient magnitudes, is popular in CT reconstruction from incomplete projection data. However, as the projection data collected are from a sparse-view of the limited scanning angular range, the results reconstructed by a TV-based method suffer from blocky artifact and gradual changed artifacts near the edges, which in turn make the reconstruction images degraded. Different from the TV, the ℓ0-norm of an image gradient counts the number of its non-zero coefficients of the image gradient. Since the regularization based on the ℓ0-norm of the image gradient will not penalize the large gradient magnitudes, the edge can be effectively retained. In this work, an edge-preserving image reconstruction method based on l0-regularized gradient prior was investigated for limited-angle computed tomography from sparse projections. To solve the optimization model effectively, the variable…
- 32top 3.5%
High pressure rheology of gas hydrate formed from multiphase systems using modified Couette rheometer
Gaurav Pandey, Praveen Linga, Jitendra Shital Sangwai
65 citationsdoi:10.1063/1.4974750OpenAlex
Show abstractHide abstract
Conventional rheometers with concentric cylinder geometries do not enhance mixing in situ and thus are not suitable for rheological studies of multiphase systems under high pressure such as gas hydrates. In this study, we demonstrate the use of modified Couette concentric cylinder geometries for high pressure rheological studies during the formation and dissociation of methane hydrate formed from pure water and water-decane systems. Conventional concentric cylinder Couette geometry did not produce any hydrates in situ and thus failed to measure rheological properties during hydrate formation. The modified Couette geometries proposed in this work observed to provide enhanced mixing in situ, thus forming gas hydrate from the gas-water-decane system. This study also nullifies the use of separate external high pressure cell for such measurements. The modified geometry was observed to measure gas hydrate viscosity from an initial condition of 0.001 Pa s to about 25 Pa s. The proposed geometries also possess the capability to measure dynamic viscoelastic properties of hydrate slurries at…
- 33top 3.6%
Invited Article: Concepts and tools for the evaluation of measurement uncertainty
Antonio M. Possolo, Hari K Iyer
63 citationsdoi:10.1063/1.4974274OpenAlex
Show abstractHide abstract
Measurements involve comparisons of measured values with reference values traceable to measurement standards and are made to support decision-making. While the conventional definition of measurement focuses on quantitative properties (including ordinal properties), we adopt a broader view and entertain the possibility of regarding qualitative properties also as legitimate targets for measurement. A measurement result comprises the following: (i) a value that has been assigned to a property based on information derived from an experiment or computation, possibly also including information derived from other sources, and (ii) a characterization of the margin of doubt that remains about the true value of the property after taking that information into account. Measurement uncertainty is this margin of doubt, and it can be characterized by a probability distribution on the set of possible values of the property of interest. Mathematical or statistical models enable the quantification of measurement uncertainty and underlie the varied collection of methods available for uncertainty…
- 34top 3.7%
Neutron and X-ray Tomography (NeXT) system for simultaneous, dual modality tomography
Jacob Michael LaManna, Daniel Seth Hussey, Elias Baltic, David L. Jacobson
62 citationsdoi:10.1063/1.4989642OpenAlex
Show abstractHide abstract
Dual mode tomography using neutrons and X-rays offers the potential of improved estimation of the composition of a sample from the complementary interaction of the two probes with the sample. We have developed a simultaneous neutron and 90 keV X-ray tomography system that is well suited to the study of porous media systems such as fuel cells, concrete, unconventional reservoir geologies, limestones, and other geological media. We present the characteristic performance of both the neutron and X-ray modalities. We illustrate the use of the simultaneous acquisition through improved phase identification in a concrete core.
- 35top 3.8%
Refractive index matched scanning and detection of soft particles
Joshua A. Dijksman, Nicolas Brodu, Robert Behringer
62 citationsOpen accessdoi:10.1063/1.4983047OpenAlex
Show abstractHide abstract
We describe here how to apply the three-dimensional imaging technique of refractive index matched scanning to hydrogel spheres. Hydrogels are water based materials with a low refractive index, which allows for index matching with water-based solvent mixtures. We discuss here various experimental techniques required to handle specifically hydrogel spheres as opposed to other transparent materials. The deformability of hydrogel spheres makes their identification in three-dimensional images non-trivial. We will also discuss numerical techniques that can be used in general to detect contacting, non-spherical particles in a three-dimensional image. The experimental and numerical techniques presented here give experimental access to the stress tensor of a packing of deformed particles.
- 36top 3.9%
Ion implantation for deterministic single atom devices
J. L. Pacheco, M. Singh, D. L. Perry, J. R. Wendt, G. Ten Eyck and 6 more
60 citationsOpen accessdoi:10.1063/1.5001520OpenAlex
Show abstractHide abstract
We demonstrate a capability of deterministic doping at the single atom level using a combination of direct write focused ion beam and solid-state ion detectors. The focused ion beam system can position a single ion to within 35 nm of a targeted location and the detection system is sensitive to single low energy heavy ions. This platform can be used to deterministically fabricate single atom devices in materials where the nanostructure and ion detectors can be integrated, including donor-based qubits in Si and color centers in diamond.
- 37top 4%
Deep underground rotation measurements: GINGERino ring laser gyroscope in Gran Sasso
Jacopo Belfi, Nicolò Beverini, Filippo Bosi, Giorgio Carelli, Davide Cuccato and 9 more
60 citationsOpen accessdoi:10.1063/1.4977051OpenAlex
Show abstractHide abstract
GINGERino is a large frame laser gyroscope investigating the ground motion in the most inner part of the underground international laboratory of the Gran Sasso, in central Italy. It consists of a square ring laser with a 3.6 m side. Several days of continuous measurements have been collected, with the apparatus running unattended. The power spectral density in the seismic bandwidth is at the level of 10−10 (rad/s)/Hz. A maximum resolution of 30 prad/s is obtained with an integration time of few hundred seconds. The ring laser routinely detects seismic rotations induced by both regional earthquakes and teleseisms. A broadband seismic station is installed on the same structure of the gyroscope. First analysis of the correlation between the rotational and the translational signal is presented.
- 38top 4.1%
Magnetic resonance imaging of granular materials
Ralf Stannarius
59 citationsOpen accessdoi:10.1063/1.4983135OpenAlex
Show abstractHide abstract
Magnetic Resonance Imaging (MRI) has become one of the most important tools to screen humans in medicine; virtually every modern hospital is equipped with a Nuclear Magnetic Resonance (NMR) tomograph. The potential of NMR in 3D imaging tasks is by far greater, but there is only "a handful" of MRI studies of particulate matter. The method is expensive, time-consuming, and requires a deep understanding of pulse sequences, signal acquisition, and processing. We give a short introduction into the physical principles of this imaging technique, describe its advantages and limitations for the screening of granular matter, and present a number of examples of different application purposes, from the exploration of granular packing, via the detection of flow and particle diffusion, to real dynamic measurements. Probably, X-ray computed tomography is preferable in most applications, but fast imaging of single slices with modern MRI techniques is unmatched, and the additional opportunity to retrieve spatially resolved flow and diffusion profiles without particle tracking is a unique feature.
- 39top 4.2%
Compact low power infrared tube furnace for in situ X-ray powder diffraction
Andrew Doran, Lukas Schlicker, Christine M. Beavers, Shrikant Bhat, Maged F. Bekheet and 1 more
59 citationsOpen accessdoi:10.1063/1.4973561OpenAlex
Show abstractHide abstract
We describe the development and implementation of a compact, low power, infrared heated tube furnace for in situ powder X-ray diffraction experiments. Our silicon carbide (SiC) based furnace design exhibits outstanding thermal performance in terms of accuracy control and temperature ramping rates while simultaneously being easy to use, robust to abuse and, due to its small size and low power, producing minimal impact on surrounding equipment. Temperatures in air in excess of 1100 °C can be controlled at an accuracy of better than 1%, with temperature ramping rates up to 100 °C/s. The complete "add-in" device, minus power supply, fits in a cylindrical volume approximately 15 cm long and 6 cm in diameter and resides as close as 1 cm from other sensitive components of our experimental synchrotron endstation without adverse effects.
- 40top 4.3%
Multi-layer thick gas electron multiplier (M-THGEM): A new MPGD structure for high-gain operation at low-pressure
M. Cortesi, Stefan Rost, W. Mittig, Yassid Ayyad, Daniel P. Bazin and 2 more
59 citationsdoi:10.1063/1.4974333OpenAlex
Show abstractHide abstract
The operating principle and performances of the Multi-layer Thick Gaseous Electron Multiplier (M-THGEM) are presented. The M-THGEM is a novel hole-type gaseous electron multiplier produced by multi-layer printed circuit board technology; it consists of a densely perforated assembly of multiple insulating substrate sheets (e.g., FR-4), sandwiched between thin metallic-electrode layers. The electron avalanche processes occur along the successive multiplication stages within the M-THGEM holes, under the action of strong dipole fields resulting from the application of suitable potential differences between the electrodes. The present work focuses on the investigation of two different geometries: a two-layer M-THGEM (either as single or double-cascade detector) and a single three-layer M-THGEM element, tested in various low-pressure He-based gas mixtures. The intrinsically robust confinement of the avalanche volume within the M-THGEM holes provides an efficient reduction of the photon-induced secondary effects, resulting in a high-gain operation over a broad pressure range, even in pure…
- 41top 4.5%
An eight-channel Doppler backscattering system in the experimental advanced superconducting tokamak
Jianqiang Hu, Chu Zhou, A. D. Liu, M. Y. Wang, E. J. Doyle and 12 more
58 citationsdoi:10.1063/1.4991855OpenAlex
Show abstractHide abstract
Doppler backscattering system can measure the perpendicular velocity and fluctuation amplitude of the density turbulence with intermediate wavenumber. An eight-channel Doppler backscattering system has been installed in the Experimental Advanced Superconducting Tokamak (EAST), which can probe eight different radial locations simultaneously by launching eight fixed frequencies (55, 57.5, 60, 62.5, 67.5, 70, 72.5, 75 GHz) into plasma. The quasi-optical system consists of circular corrugated waveguide transmission, a fixed parabolic mirror, and a rotatable parabolic mirror which are integrated with quasi-optics front-end of the profile reflectometer inside the vacuum vessel. The incidence angle can be chosen from 5° to 12°, and the wavenumber range is 2-15/cm with the wavenumber resolution Δk/k≤0.21. Ray tracing simulations are used to calculate the scattering locations and the perpendicular wavenumber. The dynamic range of this new eight-channel Doppler backscattering system can be as large as 40 dB in the EAST. In this article, the hardware design, the ray tracing, and the…
- 42top 4.6%
Extensions to the charge exchange recombination spectroscopy diagnostic suite at ASDEX Upgrade
R. M. McDermott, A. Lebschy, Benedikt Geiger, C. Bruhn, M. Cavedon and 7 more
57 citationsOpen access (CC-BY-NC-ND)doi:10.1063/1.4993131OpenAlex
Show abstractHide abstract
A new core charge exchange recombination spectroscopy diagnostic has been installed in the ASDEX Upgrade tokamak that is capable of measuring the impurity ion temperature, toroidal rotation, and density on both the low field side (LFS) and high field side (HFS) of the plasma. The new system features 48 lines-of-sight (LOS) with a radial resolution that varies from ±2 cm on the LFS down to ±0.75 cm on the HFS and has sufficient signal to run routinely at 10 ms and for special circumstances down to 2.5 ms integration time. The LFS-HFS ion temperature profiles provide an additional constraint on the magnetic equilibrium reconstruction, and the toroidal rotation frequency profiles are of sufficiently high quality that information on the poloidal velocity can be extracted from the LFS-HFS asymmetry. The diagnostic LOS are coupled to two flexible-wavelength spectrometers such that complete LFS-HFS profiles from two separate impurities can be imaged simultaneously, albeit with reduced radial coverage. More frequently, the systems measure the same impurity providing very detailed…
- 43top 4.7%
Prospects for magnetic field communications and location using quantum sensors
Vladislav P. Gerginov, F. C. S. da Silva, David A. Howe
54 citationsdoi:10.1063/1.5003821OpenAlex
Show abstractHide abstract
Signal attenuation limits the operating range in wireless communications and location. To solve the reduced range problem, we can use low-frequency signals in combination with magnetic sensing. We propose the use of an optically pumped magnetometer as a sensor and realize a proof-of-principle detection of binary phase shift keying (BPSK) modulated signals. We demonstrate a ranging enhancement by exploiting both the magnetometer’s intrinsic sensitivity of below 1 pT/Hz1/2 and its 1 kHz operating bandwidth through the use of BPSK signals.
- 44top 4.8%
A multichannel visible spectroscopy system for the ITER-like W divertor on EAST
Hongmin Mao, Fang Ding, Guang–Nan Luo, Zhenhua Hu, Xiahua Chen and 9 more
54 citationsdoi:10.1063/1.4979406OpenAlex
Show abstractHide abstract
To facilitate long-pulse high power operation, an ITER-like actively cooled tungsten (W) divertor was installed in Experimental Advanced Superconducting Tokamak (EAST) to replace the original upper graphite divertor in 2014. A dedicated multichannel visible spectroscopic diagnostic system has been accordingly developed for the characterization of the plasma and impurities in the W divertor. An array of 22 lines-of-sight (LOSs) provides a profile measurement of the light emitted from the plasma along upper outer divertor, and the other 17 vertical LOSs view the upper inner divertor, achieving a 13 mm poloidal resolution in both regions. The light emitted from the plasma is collected by a specially designed optical lens assembly and then transferred to a Czerny-Turner spectrometer via 40 m quartz fibers. At the end, the spectra dispersed by the spectrometer are recorded with an Electron-Multiplying Charge Coupled Device (EMCCD). The optical throughput and quantum efficiency of the system are optimized in the wavelength range 350-700 nm. The spectral resolution/coverage can be adjusted…
- 45top 4.9%
A new technique based on current measurement for nanoscale ferroelectricity assessment: Nano-positive up negative down
Simon Martin, Nicolas Baboux, David F. Albertini, Brice Gautier
52 citationsdoi:10.1063/1.4974953OpenAlex
Show abstractHide abstract
In this paper, we propose a new procedure which aims at measuring the polarisation switching current at the nanoscale on ferroelectric thin films with the atomic force microscope tip used as a top electrode. Our technique is an adaptation of the so-called positive up negative down method commonly operated on large electrodes. The main obstacle that must be overcome to implement such measurement is the enhancement of the signal to noise ratio, in a context where the stray capacitance of the sample/tip/lever/lever holder system generates a dielectric displacement current several orders of magnitude higher than the current to be measured. This problem is solved by the subtraction of the displacement current through a reference capacitance. For the first time, we show an example of nanoscale positive up negative down measurement of the polarisation charge on a PbZrTiO3 thin film and compare the measured value with paraelectric samples. From the comparison with macroscopic measurement, we deduce the effective area of contact between the tip and the sample.
- 46top 5%
High-speed and low-distortion solution for time-correlated single photon counting measurements: A theoretical analysis
Alessandro Cominelli, Giulia Acconcia, Pietro Peronio, Massimo Ghioni, Ivan Rech
51 citationsOpen accessdoi:10.1063/1.4996690OpenAlex
Show abstractHide abstract
In this paper, we describe a novel solution to increase the speed of Time-Correlated Single Photon Counting (TCSPC) measurements by almost an order of magnitude while providing, in principle, zero distortion regardless of the experimental conditions. Typically, the relatively long dead time associated with the conversion electronics requires a proper tune of the excitation power in order to avoid distortions of the reconstructed waveform due to pileup and counting loss. As a result, the maximum operating rate of a TCSPC channel is now limited between 1% and 5% of the excitation frequency, thus leading to relatively long acquisition times. We show that negligible distortion (below 1%) is guaranteed if the dead time associated with the converter is kept below the dead time of the detector, and at the same time the detector dead time is matched to the duration of the excitation period. In this way, unprecedented high-speed operation is possible. In this paper, we provide a theoretical analysis of the technique, including the main non-idealities which are introduced by a generic…
- 47top 5.1%
Variational mode decomposition denoising combined with the Hausdorff distance
Wenping Ma, Shuxin Yin, Chunlei Jiang, Yansheng Zhang
51 citationsdoi:10.1063/1.4978029OpenAlex
Show abstractHide abstract
Variational mode decomposition (VMD) is a recently introduced adaptive signal decomposition algorithm with a solid theoretical foundation and good noise robustness compared with empirical mode decomposition (EMD). However, there is still a problem with this algorithm associated with the selection of relevant modes. To solve this problem, this paper proposes a novel signal-filtering method that combines VMD with Hausdorff distance (HD) in the VMD-HD method. A noisy signal is first decomposed into a given number K of band-limited intrinsic mode functions by VMD. The probability density function is then estimated for each mode. The aim of this method is to reconstruct the signal using the relevant modes, which are selected on the basis of noticeable similarities between the probability density function of the input signal and that of each mode. Various similarity measures are investigated and compared, and the HD is shown to offer the best performance. The results of filtering of simulation signals illustrate the validity of the proposed method when compared with EMD-based methods…
- 48top 5.2%
Large field-of-view tiled grating structures for X-ray phase-contrast imaging
Tobias J. Schröter, Frieder Koch, Pascal Meyer, Danays Kunka, Jan Meiser and 9 more
51 citationsdoi:10.1063/1.4973632OpenAlex
Show abstractHide abstract
X-ray grating-based interferometry promises unique new diagnostic possibilities in medical imaging and materials analysis. To transfer this method from scientific laboratories or small-animal applications to clinical radiography applications, compact setups with a large field of view (FoV) are required. Currently the FoV is limited by the grating area, which is restricted due to the complex manufacturing process. One possibility to increase the FoV is tiling individual grating tiles to create one large area grating mounted on a carrier substrate. We investigate theoretically the accuracy needed for a tiling process in all degrees of freedom by applying a simulation approach. We show how the resulting precision requirements can be met using a custom-built frame for exact positioning. Precise alignment is achieved by comparing the fringe patterns of two neighboring grating tiles in a grating interferometer. With this method, the FoV can be extended to practically any desired length in one dimension. First results of a phase-contrast scanning setup with a full FoV of 384 mm × 24 mm…
- 49top 5.3%
Practical methods for generating alternating magnetic fields for biomedical research
Michael G. Christiansen, Christina M. Howe, David Currier Bono, David John Perreault, Polina Olegovna Anikeeva
50 citationsOpen accessdoi:10.1063/1.4999358OpenAlex
Show abstractHide abstract
Alternating magnetic fields (AMFs) cause magnetic nanoparticles (MNPs) to dissipate heat while leaving surrounding tissue unharmed, a mechanism that serves as the basis for a variety of emerging biomedical technologies. Unfortunately, the challenges and costs of developing experimental setups commonly used to produce AMFs with suitable field amplitudes and frequencies present a barrier to researchers. This paper first presents a simple, cost-effective, and robust alternative for small AMF working volumes that uses soft ferromagnetic cores to focus the flux into a gap. As the experimental length scale increases to accommodate animal models (working volumes of 100s of cm3 or greater), poor thermal conductivity and volumetrically scaled core losses render that strategy ineffective. Comparatively feasible strategies for these larger volumes instead use low loss resonant tank circuits to generate circulating currents of 1 kA or greater in order to produce the comparable field amplitudes. These principles can be extended to the problem of identifying practical routes for scaling AMF…
- 50top 5.4%
Tungsten-rhenium thin film thermocouples for SiC-based ceramic matrix composites
Bian Tian, Zhongkai Zhang, Peng Shi, Zheng Chen, Qiuyue Yu and 2 more
50 citationsdoi:10.1063/1.4973967OpenAlex
Show abstractHide abstract
A tungsten-rhenium thin film thermocouple is designed and fabricated, depending on the principle of thermal-electric effect caused by the high temperature. The characteristics of thin film thermocouples in different temperatures are investigated via numerical analysis and analog simulation. The working mechanism and thermo-electric features of the thermocouples are analyzed depending on the simulation results. Then the thin film thermocouples are fabricated and calibrated. The calibration results show that the thin film thermocouples based on the tungsten-rhenium material achieve ideal static characteristics and work well in the practical applications.
How to read this list
The cohort is every article, review and book chapter OpenAlex attributes to Review of Scientific Instruments with publication year 2017, excluding retracted works and paratext such as editorials and errata. The top 50 by citation count are listed; the percentile is the rank divided by the cohort size. 50 of the 50 entries have an abstract in OpenAlex. Counts were read on 29 October 2026 and will not be updated on this page, so a quoted rank stays verifiable. Full rules on the methodology page.
Other journals, same idea
Work with these 25 papers in Kahubi
- The papers land in your library with their DOIs
- Ask anything across all of them, with citations
- Draft a literature review from the same sources
Free plan, no card. Your files stay private unless you share them.
Reading several of these?
Kahubi reads papers with you, keeps every citation traceable and drafts with sources you can check. Free plan, no card.