Most-cited articles · 2022
The 50 most-cited articles in Review of Scientific Instruments, 2022
Ranked by OpenAlex citation count on 29 October 2026, out of 913 eligible articles Review of Scientific Instruments published in 2022. Ranks are frozen; this page will not change. Number one, with 141 citations: The QICK (Quantum Instrumentation Control Kit): Readout and control for qubits and detectors.
- Cohort
- 913 articles
- Listed
- Top 50 (5.5%)
- Open access
- 34 of 50
- Snapshot
- 2026-10-29
The 2022 list is led by instrumentation for quantum computing and quantum sensing, with the QICK qubit controller by Stefanazzi, Treptow, Wilcer and colleagues at 141 citations, followed by a micro-focused angle-resolved photoemission spectroscopy system at 62 citations and micro-fabricated components for cold atom sensors at 55 citations. Other highly cited entries cover precision metrology, plasma and fusion diagnostics, and low-noise electronics for biomedical recording.
The ranking, based on OpenAlex citation counts among 913 eligible articles, offers a snapshot of which instrument designs and methods attracted the most attention in 2022. Readers can use the titles and abstracts to identify recurring themes and to locate the original papers for detail.
Introduction written from the titles and abstracts on this list. Every figure below is the source.
Ask about these papers
Grounded in this list only, with sources.
- 1top 0.2%
The QICK (Quantum Instrumentation Control Kit): Readout and control for qubits and detectors
Leandro Stefanazzi, Kenneth Treptow, Neal Wilcer, Chris Stoughton, Collin Bradford and 12 more
141 citationsOpen accessdoi:10.1063/5.0076249OpenAlex
Show abstractHide abstract
We introduce a Xilinx RF System-on-Chip (RFSoC)-based qubit controller (called the Quantum Instrumentation Control Kit, or QICK for short), which supports the direct synthesis of control pulses with carrier frequencies of up to 6 GHz. The QICK can control multiple qubits or other quantum devices. The QICK consists of a digital board hosting an RFSoC field-programmable gate array, custom firmware, and software and an optional companion custom-designed analog front-end board. We characterize the analog performance of the system as well as its digital latency, important for quantum error correction and feedback protocols. We benchmark the controller by performing standard characterizations of a transmon qubit. We achieve an average gate fidelity of Favg=99.93%. All of the schematics, firmware, and software are open-source.
- 2top 0.3%
Development of a versatile micro-focused angle-resolved photoemission spectroscopy system with Kirkpatrick–Baez mirror optics
Miho Kitamura, S. Souma, Asuka Honma, Daisuke Wakabayashi, Hirokazu Tanaka and 9 more
62 citationsOpen accessdoi:10.1063/5.0074393OpenAlex
Show abstractHide abstract
Angle-resolved photoemission spectroscopy using a micro-focused beam spot [micro-angle-resolved photoemission spectroscopy (ARPES)] is becoming a powerful tool to elucidate key electronic states of exotic quantum materials. We have developed a versatile micro-ARPES system based on the synchrotron radiation beam focused with a Kirkpatrick-Baez mirror optics. The mirrors are monolithically installed on a stage, which is driven with five-axis motion, and are vibrationally separated from the ARPES measurement system. Spatial mapping of the Au photolithography pattern on Si signifies the beam spot size of 10 µm (horizontal) × 12 µm (vertical) at the sample position, which is well suited to resolve the fine structure in local electronic states. Utilization of the micro-beam and the high precision sample motion system enables the accurate spatially resolved band-structure mapping, as demonstrated by the observation of a small band anomaly associated with tiny sample bending near the edge of a cleaved topological insulator single crystal.
- 3top 0.4%
Micro-fabricated components for cold atom sensors
J. P. McGilligan, Kevin Francis Gallacher, Paul F. Griffin, Douglas J. Paul, Aidan S. Arnold and 1 more
55 citationsOpen access (CC-BY)doi:10.1063/5.0101628OpenAlex
Show abstractHide abstract
Laser cooled atoms have proven transformative for precision metrology, playing a pivotal role in state-of-the-art clocks and interferometers and having the potential to provide a step-change in our modern technological capabilities. To successfully explore their full potential, laser cooling platforms must be translated from the laboratory environment and into portable, compact quantum sensors for deployment in practical applications. This transition requires the amalgamation of a wide range of components and expertise if an unambiguously chip-scale cold atom sensor is to be realized. We present recent developments in cold-atom sensor miniaturization, focusing on key components that enable laser cooling on the chip-scale. The design, fabrication, and impact of the components on sensor scalability and performance will be discussed with an outlook to the next generation of chip-scale cold atom devices.
- 4top 0.5%
A setup for studies of photoelectron circular dichroism from chiral molecules in aqueous solution
Sebastian Malerz, Henrik Haak, Florian Trinter, Anne B. Stephansen, Claudia Kolbeck and 4 more
44 citationsOpen access (CC-BY)doi:10.1063/5.0072346OpenAlex
Show abstractHide abstract
We present a unique experimental design that enables the measurement of photoelectron circular dichroism (PECD) from chiral molecules in aqueous solution. The effect is revealed from the intensity difference of photoelectron emission into a backward-scattering angle relative to the photon propagation direction when ionizing with circularly polarized light of different helicity. This leads to asymmetries (normalized intensity differences) that depend on the handedness of the chiral sample and exceed the ones in conventional dichroic mechanisms by orders of magnitude. The asymmetry is largest for photon energies within several electron volts above the ionization threshold. A primary aim is to explore the effect of hydration on PECD. The modular and flexible design of our experimental setup EASI (Electronic structure from Aqueous Solutions and Interfaces) also allows for detection of more common photoelectron angular distributions, requiring distinctively different detection geometries and typically using linearly polarized light. A microjet is used for liquid-sample delivery. We…
- 5top 0.6%
Wind energy harvester using piezoelectric materials
Caijiang Lu, Xueling Jiang, Linfeng Li, Haidong D. Zhou, Aichao Yang and 3 more
40 citationsdoi:10.1063/5.0065462OpenAlex
Show abstractHide abstract
Wireless sensor networks play a very important role in environmental monitoring, structural health monitoring, smart city construction, smart grid, and ecological agriculture. The wireless sensor nodes powered by a battery have a limited service life and need periodic maintenance due to the limitation of battery capacity. Fortunately, the development of environmental energy harvesting technology provides an effective way to eliminate the needs and the replacement of the batteries. Among the environmental stray energy, wind energy is rich, almost endless, widely distributed, and clean. Due to the advantages of simple structure, miniaturization, and high power density, wind energy harvesters using piezoelectric materials (PWEHs) have attracted much attention. By the ways of principal exploration, structure design, and performance optimization, great and steady progress has been made in the research of PWEH. This Review is focused on the review of PWEHs. After introducing the basic principle of PWEHs, the structural performance and research status of PWEHs based on different…
- 6top 0.7%
The very large n2EDM magnetically shielded room with an exceptional performance for fundamental physics measurements
N. J. Ayres, G. Ban, G. Bison, K. Bodek, В. М. Бондар and 25 more
39 citationsOpen access (CC-BY)doi:10.1063/5.0101391OpenAlex
Show abstractHide abstract
We present the magnetically shielded room (MSR) for the n2EDM experiment at the Paul Scherrer Institute, which features an interior cubic volume with each side of length 2.92 m, thus providing an accessible space of 25 m3. The MSR has 87 openings of diameter up to 220 mm for operating the experimental apparatus inside and an intermediate space between the layers for housing sensitive signal processing electronics. The characterization measurements show a remanent magnetic field in the central 1 m3 below 100 pT and a field below 600 pT in the entire inner volume, up to 4 cm to the walls. The quasi-static shielding factor at 0.01 Hz measured with a sinusoidal 2 μT peak-to-peak signal is about 100 000 in all three spatial directions and increases rapidly with frequency to reach 108 above 1 Hz.
- 7top 0.8%
Fusion product measurements by nuclear diagnostics in the Joint European Torus deuterium–tritium 2 campaign (invited)
M. Nocente, V. Kiptily, M. Tardocchi, P. J. Bonofiglo, T. Craciunescu and 25 more
36 citationsOpen accessdoi:10.1063/5.0101767OpenAlex
Show abstractHide abstract
A new deuterium–tritium experimental, DTE2, campaign has been conducted at the Joint European Torus (JET) between August 2021 and late December 2021. Motivated by significant enhancements in the past decade at JET, such as the ITER-like wall and enhanced auxiliary heating power, the campaign achieved a new fusion energy world record and performed a broad range of fundamental experiments to inform ITER physics scenarios and operations. New capabilities in the area of fusion product measurements by nuclear diagnostics were available as a result of a decade long enhancement program. These have been tested for the first time in DTE2 and a concise overview is provided here. Confined alpha particle measurements by gamma-ray spectroscopy were successfully demonstrated, albeit with limitations at neutron rates higher than some 1017 n/s. High resolution neutron spectroscopy measurements with the magnetic proton recoil instrument were complemented by novel data from a set of synthetic diamond detectors, which enabled studies of the supra-thermal contributions to the neutron emission. In the…
- 8top 0.9%
Design of a low-noise low-voltage amplifier for improved neural signal recording
Kulbhushan Sharma, Rahul Kumar Tripathi, H. S. Jatana, Rajnish Sharma
35 citationsdoi:10.1063/5.0087527OpenAlex
Show abstractHide abstract
Design of amplifier circuits with low-noise operable at low-power to be used, especially for implantable neural interfaces, remains a huge challenge. This research paper presents the design of a low-noise low-voltage neural recording amplifier suitable for amplifying local field potentials and extracellular action potentials so as to meet the end requirement of an implantable neuro-medical system. Critical performance parameters of the smaller circuit blocks of the complete neural amplifier architecture have been found with the help of detailed mathematical analysis and then verified by the simulations conducted using 0.18 µm 4M1P foundry Semi-conductor Laboratory N-well process. The neural amplifier design proposed in this paper passes neural signal of interest with a mid-band gain of 49.9 dB over a bandwidth of 5.3 Hz–8.6 kHz, draws only 11.5 µW of power from ±0.9 V supply voltage, and exhibits an input-referred noise of 2.6 µVrms with a noise efficiency factor of 2.27. The area consumed by the proposed neural amplifier architecture is 0.192 mm2. The complete circuit design…
- 9top 1%
Linien: A versatile, user-friendly, open-source FPGA-based tool for frequency stabilization and spectroscopy parameter optimization
Benjamin Wiegand, Bastian Leykauf, Robert Jördens, Markus Krutzik
34 citationsOpen access (CC-BY)doi:10.1063/5.0090384OpenAlex
Show abstractHide abstract
We present a user-friendly and versatile tool for laser frequency stabilization. Its main focus is spectroscopy locking, but the software is suitable for lock-in techniques in general as well as bare proportional-integral-derivative (PID) operation. Besides allowing for sinusoidal modulation (up to 50 MHz), triangular ramp scanning, in-phase and quadrature demodulation (1-5 f), infinite impulse response, and PID filtering, Linien features two different algorithms for automatic lock point selection; one of them performs time-critical tasks completely on field-programmable gate arrays. Linien is capable of autonomously optimizing spectroscopy parameters by means of machine learning and can measure the error signal's power spectral density. The software is built in a modular way, providing both a graphical user interface as well as a Python scripting interface. It is based on the RedPitaya STEMLab platform but may be ported to different systems.
- 10top 1.1%
Unshielded portable optically pumped magnetometer for the remote detection of conductive objects using eddy current measurements
Lucas M. Rushton, Tadas Pyragius, Adil Meraki, L. Elson, Kasper Jensen
33 citationsOpen access (CC-BY)doi:10.1063/5.0102402OpenAlex
Show abstractHide abstract
Electrically conductive objects can be detected using the principle of electromagnetic induction, where a primary oscillating magnetic field induces eddy currents in the object, which in turn produce a secondary magnetic field that can be measured with a magnetometer. We have developed a portable radio-frequency optically pumped magnetometer (RF OPM) working in unshielded conditions with sub-pT/Hz magnetic field sensitivity when used for the detection of small oscillating magnetic fields, setting a new benchmark for the sensitivity of a portable RF OPM in unshielded conditions. Using this OPM, we have detected the induced magnetic field from aluminum disks with diameters as small as 1.5 cm and with the disks being ∼25 cm from both the excitation coil and the magnetometer. When used for eddy current detection, our magnetometer achieves a sensitivity of a 2-6 pT/Hz. We have also detected a moving aluminum disk using our RF OPM and analyzed the magnetometer signals, which depend on the position of the disk, illustrating the potential of high sensitivity RF OPMs for remote sensing…
- 11top 1.3%
Spatially resolved diagnostics for optimization of large ion beam sources
G. Serianni, E. Sartori, R. Agnello, P. Agostinetti, M. Agostini and 20 more
33 citationsOpen access (CC-BY-NC-ND)doi:10.1063/5.0084797OpenAlex
Show abstractHide abstract
Giant negative ion sources for neutral beam injectors deliver huge negative ion currents, thanks to their multi-beamlet configuration. As the single-beamlet optics defines the transmission losses along the beamline, the extraction of a similar current for all beamlets is extremely desirable, in order to facilitate the beam source operation (i.e., around perveance match). This Review investigates the correlation between the vertical profile of beam intensity and the vertical profiles of plasma properties at the extraction region of the source, focusing on the influence of increasing cesium injection. Only by the combined use of all available source diagnostics, described in this Review, can beam features on the scale of the non-uniformities be investigated with a sufficient space resolution. At RF power of 50 kW/driver, with intermediate bias currents and a filter field of 2.4 mT, it is found that the central part of the four vertical beam segments exhibits comparable plasma density and beamlet currents; at the edges of the central segments, both the beam and electron density appear…
- 12top 1.4%
A compound pendulum for thrust measurement of micro-Newton thruster
Hao Xu, Yong Gao, Qiangbing Mao, Liang-Wen Ye, Zhong-Kun Hu and 3 more
33 citationsdoi:10.1063/5.0090980OpenAlex
Show abstractHide abstract
A thrust stand is developed for testing micro-Newton level thrusters on the ground. The stand is composed of a compound pendulum that is symmetrically suspended by two thin beryllium copper strips, and it is precisely calibrated by gravity. The stiffness of the stand can be adjusted in 3 orders of magnitude by a counterweight. When the stiffness is larger than 1 Nm/rad, the stand demonstrates a fast response to thrust. The measured range of the stand reaches 1000 μN, and the noise is less than 0.1 μN/Hz within 1 mHz-1 Hz. To calibrate the resolution of the stand, an electrostatic force is applied to the stand with an actuator. The equivalent thrust is determined to be 0.09 μN with a standard uncertainty of 0.02 μN. Using the stand, a micro-Newton colloid thruster is tested. The output of the colloid thruster changes with the applied voltage as 0.015(1) μN/V. When changing the voltage by 50 V, the change in thrust is measured to be 0.7 μN with a standard uncertainty of 0.1 μN.
- 13top 1.5%
Characterization of a new ultra-high pressure shock tube facility for combustion and propulsion studies
Justin J. Urso, Cory Kinney, Anthony Carmine Terracciano, Samuel Barak, Andrew R. Laich and 4 more
32 citationsdoi:10.1063/5.0084047OpenAlex
Show abstractHide abstract
A new shock tube facility has been designed, constructed, and characterized at the University of Central Florida. This facility is capable of withstanding pressures of up to 1000 atm, allowing for combustion diagnostics of extreme conditions, such as in rocket combustion chambers or in novel power conversion cycles. For studies with toxic gas impurities, the high initial pressures required the development of a gas delivery system to ensure the longevity of the facility and the safety of the personnel. Data acquisition and experimental propagation were implemented with remote access to ensure safety, paired with a LabVIEW- and Python-based user interface. Thus far, test pressures of 270 atm, blast pressures of 730 atm, and temperatures approaching 10 000 K have been achieved. The extreme limitations of this facility allow for emission spectroscopy to be performed during the oxidation of fuel mixtures, e.g., alkanes diluted in argon and carbon dioxide. Ignition delay times were determined and compared to simulations using chemical kinetic mechanisms. The design, experimental…
- 14top 1.6%
FPGA-based electronic system for the control and readout of superconducting quantum processors
Yuchen Yang, Zhongtao Shen, Xing Zhu, Ziqi Wang, Gengyan Zhang and 4 more
31 citationsOpen accessdoi:10.1063/5.0085467OpenAlex
Show abstractHide abstract
Electronic systems for qubit control and measurement serve as a bridge between quantum programming language and quantum information processors. With the rapid development of superconducting quantum circuit technology, synchronization in a large-scale system, low-latency execution, and low noise are required for electronic systems. Here, we present a field-programmable gate array (FPGA)-based electronic system with a distributed synchronous clock and trigger architecture. The system supports synchronous control of qubits with jitters of ∼5 ps. We implement a real-time digital signal processing system in the FPGA, enabling precise timing control, arbitrary waveform generation, in-phase and quadrature demodulation for qubit state discrimination, and the generation of real-time qubit-state-dependent trigger signals for feedback/feedforward control. The hardware and firmware low-latency design reduces the feedback/feedforward latency of the electronic system to 125 ns, significantly less than the decoherence times of the qubit. Finally, we demonstrate the functionalities and low-noise…
- 15top 1.7%
Development of a scanning tunneling microscope for variable temperature electron spin resonance
Jiyoon Hwang, Denis S. Krylov, R. J. G. Elbertse, Sang Won Yoon, Taehong Ahn and 6 more
30 citationsOpen access (CC-BY)doi:10.1063/5.0096081OpenAlex
Show abstractHide abstract
Recent advances in improving the spectroscopic energy resolution in scanning tunneling microscopy (STM) have been achieved by integrating electron spin resonance (ESR) with STM. Here, we demonstrate the design and performance of a homebuilt STM capable of ESR at temperatures ranging from 1 to 10 K. The STM is incorporated with a homebuilt Joule-Thomson refrigerator and a two-axis vector magnet. Our STM design allows for the deposition of atoms and molecules directly into the cold STM, eliminating the need to extract the sample for deposition. In addition, we adopt two methods to apply radio-frequency (RF) voltages to the tunnel junction: the early design of wiring to the STM tip directly and a more recent idea to use an RF antenna. Direct comparisons of ESR results measured using the two methods and simulations of electric field distribution around the tunnel junction show that, despite their different designs and capacitive coupling to the tunnel junction, there is no discernible difference in the driving and detection of ESR. Furthermore, at a magnetic field of ∼1.6 T, we observe…
- 16top 1.8%
A laser powder bed fusion system for operando synchrotron x-ray imaging and correlative diagnostic experiments at the Stanford Synchrotron Radiation Lightsource
Aiden A. Martin, Jenny Wang, Philip J. Depond, Maria Strantza, Jean‐Baptiste Forien and 9 more
30 citationsdoi:10.1063/5.0080724OpenAlex
Show abstractHide abstract
Laser powder bed fusion (LPBF) is a highly dynamic multi-physics process used for the additive manufacturing (AM) of metal components. Improving process understanding and validating predictive computational models require high-fidelity diagnostics capable of capturing data in challenging environments. Synchrotron x-ray techniques play a vital role in the validation process as they are the only in situ diagnostic capable of imaging sub-surface melt pool dynamics and microstructure evolution during LPBF-AM. In this article, a laboratory scale system designed to mimic LPBF process conditions while operating at a synchrotron facility is described. The system is implemented with process accurate atmospheric conditions, including an air knife for active vapor plume removal. Significantly, the chamber also incorporates a diagnostic sensor suite that monitors emitted optical, acoustic, and electronic signals during laser processing with coincident x-ray imaging. The addition of the sensor suite enables validation of these industrially compatible single point sensors by detecting pore…
- 17top 1.9%
Recent advances in microresonators and supporting instrumentation for electron paramagnetic resonance spectroscopy
Nandita Abhyankar, Amit Kumar Agrawal, Jason Paul Campbell, Thorsten Maly, Pragya Rasmi Shrestha and 1 more
29 citationsOpen access (PUBLIC-DOMAIN)doi:10.1063/5.0097853OpenAlex
Show abstractHide abstract
Electron paramagnetic resonance (EPR) spectroscopy characterizes the magnetic properties of paramagnetic materials at the atomic and molecular levels. Resonators are an enabling technology of EPR spectroscopy. Microresonators, which are miniaturized versions of resonators, have advanced inductive-detection EPR spectroscopy of mass-limited samples. Here, we provide our perspective of the benefits and challenges associated with microresonator use for EPR spectroscopy. To begin, we classify the application space for microresonators and present the conceptual foundation for analysis of resonator sensitivity. We summarize previous work and provide insight into the design and fabrication of microresonators as well as detail the requirements and challenges that arise in incorporating microresonators into EPR spectrometer systems. Finally, we provide our perspective on current challenges and prospective fruitful directions.
- 18top 2%
Achieving high speed of the stick–slip piezoelectric actuator at low frequency by using a two-stage amplification mechanism (TSAM)
Chunxue Yi, Zhi Ming Xu, Wenyang Zhao, Yao-Ming Huang, Yicheng Li and 1 more
28 citationsdoi:10.1063/5.0065174OpenAlex
Show abstractHide abstract
The stick-slip piezoelectric actuator is a promising type for precision positioning with large stroke and high resolution; however, it is still challenging to achieve high motion speed at a relatively low driving frequency. To solve this problem, a novel two-stage amplification mechanism (TSAM) was designed, and correspondingly, a stick-slip piezoelectric actuator was developed. The structure, two-stage amplification principle, and motion processes of the designed actuator were addressed in detail, followed by analyzing the displacement amplification ratio and stress of TSAM via the elastic beam method and finite element method, respectively. Then, the actuator prototype was fabricated, and its output performances were tested under various experimental parameters. By comparative analysis with the actuator that only used the first-stage amplification hinge, the significant improvement in stepping displacement was verified when employing the TSAM. The resultant maximum motion speed was 20.05 mm/s, achieved under the locking force of 2 N, the input voltage of 100 V, and the driving…
- 19top 2.1%
0.342 nW Class-AB enhanced flipped source follower low pass filter for biomedical applications
Diksha Thakur, Kulbhushan Sharma
27 citationsdoi:10.1063/5.0108207OpenAlex
Show abstractHide abstract
Owing to the impact of process voltage and temperature variations, the design of low-power low-pass filters (LPFs) with improved linearity is still one of the most challenging tasks for effective biological signal processing. This paper presents the design of a fourth-order Class-AB enhanced flipped source follower (EFSF) LPF circuit aimed at the detection of electroencephalography signals. The simulated results attained using complementary metal–oxide–semiconductor 180 nm technology node in Cadence Analog Design Environment demonstrate that the EFSF LPF emulates a DC-gain of −88 mdB with a bandwidth of 100 Hz and consumes 0.342 nW power from a supply voltage of 0.5 V. The calculated figure of merit for the proposed filter is 5.983 × 10−15 J with a dynamic range (DR) of 43.54 dB and input-referred noise of 91 µVrms. It consumes an area of 0.0458 mm2. To check the robustness of the proposed filter circuit, we performed Monte Carlo simulations with 200 runs. The statistical results achieved for the DC-gain, DR, and total harmonic distortion of the proposed filter show mean values of…
- 20top 2.2%
A three-dimensional small angle measurement system based on autocollimation method
Wenran Ren, Jiwen Cui, Jiubin Tan
27 citationsdoi:10.1063/5.0089964OpenAlex
Show abstractHide abstract
A laser autocollimator based on transmission grating and combined reflector is proposed to simultaneously measure a three-dimensional angle. The optical configuration of the proposed autocollimator is designed, and a mathematical model for measuring a three-dimensional angle is established. The three-dimensional angle is obtained by detecting the change in the direction of the three measurement beams generated by grating diffraction and reflected by a combined reflector. The experimental setup based on the proposed autocollimator was constructed, and a series of experiments were performed to verify the feasibility of the proposed autocollimator for precision angle measurement. The experimental results showed that the measurement resolution of three-dimensional angles is better than 0.01", with measurement repeatability of yaw, pitch, and roll angles being 0.013", 0.012", and 0.009", respectively.
- 21top 2.4%
Gas puff imaging on the TCV tokamak
N. Offeddu, C. Wüthrich, W. Han, C. Theiler, T. Golfinopoulos and 12 more
26 citationsOpen access (CC-BY)doi:10.1063/5.0126398OpenAlex
Show abstractHide abstract
We present the design and operation of a suite of Gas Puff Imaging (GPI) diagnostic systems installed on the Tokamak à Configuration Variable (TCV) for the study of turbulence in the plasma edge and Scrape-Off-Layer (SOL). These systems provide the unique ability to simultaneously collect poloidal 2D images of plasma dynamics at the outboard midplane, around the X-point, in both the High-Field Side (HFS) and Low-Field Side (LFS) SOL, and in the divertor region. We describe and characterize an innovative control system for deuterium and helium gas injection, which is becoming the default standard for the other gas injections at TCV. Extensive pre-design studies and the different detection systems are presented, including an array of avalanche photodiodes and a high-speed CMOS camera. First results with spatial and time resolutions of up to ≈2 mm and 0.5 µs, respectively, are described, and future upgrades of the GPI diagnostics for TCV are discussed.
- 22top 2.5%
An ion mobility mass spectrometer coupled with a cryogenic ion trap for recording electronic spectra of charged, isomer-selected clusters
Jack T. Buntine, Eduardo Carrascosa, James N. Bull, Ugo Jacovella, Mariah I. Cotter and 6 more
26 citationsOpen accessdoi:10.1063/5.0085680OpenAlex
Show abstractHide abstract
Infrared and electronic spectra are indispensable for understanding the structural and energetic properties of charged molecules and clusters in the gas phase. However, the presence of isomers can potentially complicate the interpretation of spectra, even if the target molecules or clusters are mass-selected beforehand. Here, we describe an instrument for spectroscopically characterizing charged molecular clusters that have been selected according to both their isomeric form and their mass-to-charge ratio. Cluster ions generated by laser ablation of a solid sample are selected according to their collision cross sections with helium buffer gas using a drift tube ion mobility spectrometer and their mass-to-charge ratio using a quadrupole mass filter. The mobility- and mass-selected target ions are introduced into a cryogenically cooled, three-dimensional quadrupole ion trap where they are thermalized through inelastic collisions with an inert buffer gas (He or He/N2 mixture). Spectra of the molecular ions are obtained by tagging them with inert atoms or molecules (Ne and N2), which…
- 23top 2.6%
Microwave techniques for electron cyclotron resonance plasma diagnostics
D. Mascali, E. Naselli, Giuseppe Torrisi
26 citationsdoi:10.1063/5.0075496OpenAlex
Show abstractHide abstract
This paper reviews the main microwave diagnostic techniques and tools adopted in electron cyclotron resonance (ECR) (and others) ion source laboratories, with a special focus on techniques and instruments developed at INFN-LNS. Along with the tools used for optimization of microwave launching (power monitors, spectral analysis, and network analyzers), this paper deals, in particular, with more recent devices on-purpose developed to perform in-plasma analysis, such as absolute density measurements and density profiles retrieval. Among these, the first example of microwave interferometry for ECR compact machines (the VESPRI interferometer at INFN-LNS) will be briefly discussed, in combination with microwave polarimetric techniques based on Faraday rotation detection. More sophisticated microwave techniques are going to be designed and are now at a numerical study stage, e.g., profilometry and imaging via inverse scattering methods (this paper will offer short theoretical bases and first numerical results on 1D profilometry). In the end, the relevance about the implications and…
- 24top 2.7%
An ultrafast piezoelectric Z-scanner with a resonance frequency above 1.1 MHz for high-speed atomic force microscopy
Masahiro Shimizu, Chihiro Okamoto, Kenichi Umeda, Shinji Watanabe, Toshio Ando and 1 more
26 citationsOpen access (CC-BY)doi:10.1063/5.0072722OpenAlex
Show abstractHide abstract
The Z-scanner is the major component limiting the speed performance of all current high-speed atomic force microscopy systems. Here, we present an ultrafast piezoelectric Z-scanner with a resonance frequency above 1.1 MHz, achieving a record response time of ∼0.14 µs, approximately twice as fast as conventional piezoelectric-based Z-scanners. In the mechanical design, a small piezo-stack is supported at its bottom four vertices on a cone-like hollow, allowing the resonance frequency of the Z-scanner to remain as high as that of the piezo in free vibration. Its maximum displacement, ∼190 nm at 50 V, is large enough for imaging bio-molecules. For imaging bio-molecules in a buffer solution, the upper half of the Z-scanner is wrapped in a thin film resistant to water and chemicals, providing an excellent waterproof and mechanical durability without lowering the resonance frequency. We demonstrate that this Z-scanner can observe actin filaments, fragile biological polymers, for more than five times longer than the conventional Z-scanner at a tip velocity of 800 µm/s.
- 25top 2.8%
ITER collective Thomson scattering—Preparing to diagnose fusion-born alpha particles (invited)
S. B. Korsholm, A. Chambon, B. Gonçalves, V. Infante, Thomas A. Jensen and 16 more
25 citationsOpen accessdoi:10.1063/5.0101867OpenAlex
Show abstractHide abstract
The ITER Collective Thomson scattering (CTS) diagnostic will measure the dynamics of fusion-born alpha particles in the burning ITER plasma by scattering a 1 MW 60 GHz gyrotron beam off fast-ion induced fluctuations in the plasma. The diagnostic will have seven measurement volumes across the ITER cross section and will resolve the alpha particle energies in the range from 300 keV to 3.5 MeV; importantly, the CTS diagnostic is the only diagnostic capable of measuring confined alpha particles for energies below ∼1.7 MeV and will also be sensitive to the other fast-ion populations. The temporal resolution is 100 ms, allowing the capture of dynamics on that timescale, and the typical spatial resolution is 10-50 cm. The development and design of the in-vessel and primary parts of the CTS diagnostic has been completed. This marks the beginning of a new phase of preparation to maximize the scientific benefit of the diagnostic, e.g., by investigating the capability to contribute to the determination of the fuel-ion ratio and the bulk ion temperature as well as integrating data analysis with…
- 26top 2.9%
CENTAUR—The small- and wide-angle neutron scattering diffractometer/spectrometer for the Second Target Station of the Spallation Neutron Source
Shuo Qian, William T. Heller, Wei‐Ren Chen, Andrew D Christianson, Changwoo Do and 7 more
25 citationsOpen access (CC-BY)doi:10.1063/5.0090527OpenAlex
Show abstractHide abstract
CENTAUR has been selected as one of the eight initial instruments to be built at the Second Target Station (STS) of the Spallation Neutron Source at Oak Ridge National Laboratory. It is a small-angle neutron scattering (SANS) and wide-angle neutron scattering (WANS) instrument with diffraction and spectroscopic capabilities. This instrument will maximally leverage the high brightness of the STS source, the state-of-the-art neutron optics, and a suite of detectors to deliver unprecedented capabilities that enable measurements over a wide range of length scales with excellent resolution, measurements on smaller samples, and time-resolved investigations of evolving structures. Notably, the simultaneous WANS and diffraction capability will be unique among neutron scattering instruments in the United States. This instrument will provide much needed capabilities for soft matter and polymer sciences, geology, biology, quantum condensed matter, and other materials sciences that need in situ and operando experiments for kinetic and/or out-of-equilibrium studies. Beam polarization and a…
- 27top 3%
Ultrafast disruptive probing: Simultaneously keeping track of tens of reaction pathways
Bethany Jochim, Lindsey DeJesus, Marcos M. Dantus
25 citationsOpen accessdoi:10.1063/5.0084837OpenAlex
Show abstractHide abstract
Ultrafast science depends on different implementations of the well-known pump-probe method. Here, we provide a formal description of ultrafast disruptive probing, a method in which the probe pulse disrupts a transient species that may be a metastable ion or a transient state of matter. Disruptive probing has the advantage of allowing for simultaneous tracking of the yield of tens of different processes. Our presentation includes a numerical model and experimental data on multiple products resulting from the strong-field ionization of two different molecules, partially deuterated methanol and norbornene. The correlated enhancement and depletion signals between all the different fragmentation channels offer comprehensive information on photochemical reaction pathways. In combination with ion imaging and/or coincidence momentum imaging or as complementary to atom-specific probing or ultrafast diffraction methods, disruptive probing is a particularly powerful tool for the study of strong-field laser-matter interactions.
- 28top 3.1%
Ultrafast time- and angle-resolved photoemission spectroscopy with widely tunable probe photon energy of 5.3–7.0 eV for investigating dynamics of three-dimensional materials
Changhua Bao, Haoyuan Zhong, Shaohua Zhou, Runfa Feng, Yuan Wang and 1 more
25 citationsOpen accessdoi:10.1063/5.0070004OpenAlex
Show abstractHide abstract
Time- and angle-resolved photoemission spectroscopy (TrARPES) is a powerful technique for capturing the ultrafast dynamics of charge carriers and revealing photo-induced phase transitions in quantum materials. However, the lack of widely tunable probe photon energy, which is critical for accessing the dispersions at different out-of-plane momentum kz in TrARPES measurements, has hindered the ultrafast dynamics investigation of 3D quantum materials, such as Dirac or Weyl semimetals. Here, we report the development of a TrARPES system with a highly tunable probe photon energy from 5.3 to 7.0 eV. The tunable probe photon energy is generated by the fourth harmonic generation of a tunable wavelength femtosecond laser source by combining a β-BaB2O4 crystal and a KBe2BO3F2 crystal. A high energy resolution of 29–48 meV and time resolution of 280–320 fs are demonstrated on 3D topological materials ZrTe5 and Sb2Te3. Our work opens up new opportunities for exploring ultrafast dynamics in 3D quantum materials.
- 29top 3.2%
RADCAM—A radiation camera system combining foil bolometers, AXUV diodes, and filtered soft x-ray diodes
Umar Ahmed Sheikh, L. Simons, B.P. Duval, O. Février, D. Moret and 5 more
24 citationsOpen access (CC-BY)doi:10.1063/5.0095907OpenAlex
Show abstractHide abstract
Measurements of radiated power are critical for characterizing and optimizing tokamak performance. The RADCAM system, comprising arrays of foil bolometers, Absolute eXtreme UltraViolet (AXUV), and filtered soft x-ray diodes, has been constructed to provide improved measurements of plasma radiation on "Tokamak a Configuration Variable" (TCV). An overview of the physical geometry, electronics, and design of the system is provided. The construction of the bolometer foils together with the improved sensitivity characteristics resulting from the inclusion of an anti-reflection carbon coating are presented. The large number of lines of sight in RADCAM are shown to significantly increase the spatial resolution over the legacy system. The system calibration procedure is detailed, and the mean system sensitivity is shown to vary by less than 5% over 1000 discharges. Additionally, the methodology for cross-calibration of the AXUV diodes with the bolometer foils is presented and applied to generate high temporal resolution measurements. The RADCAM radiation camera system is a compact,…
- 30top 3.3%
ICARUS-Q: Integrated control and readout unit for scalable quantum processors
Kun Hee Park, Yung Szen Yap, Yuanzheng Paul Tan, Christoph Hufnagel, Long Hoang Nguyen and 6 more
23 citationsOpen accessdoi:10.1063/5.0081232OpenAlex
Show abstractHide abstract
We present a control and measurement setup for superconducting qubits based on the Xilinx 16-channel radio-frequency system-on-chip (RFSoC) device. The proposed setup consists of four parts: multiple RFSoC boards, a setup to synchronize every digital to analog converter (DAC) and analog to digital converter (ADC) channel across multiple boards, a low-noise direct current supply for tuning the qubit frequency, and cloud access for remotely performing experiments. We also designed the setup to be free of physical mixers. The RFSoC boards directly generate microwave pulses using sixteen DAC channels up to the third Nyquist zone, which are directly sampled by its eight ADC channels between the fifth and the ninth zones.
- 31top 3.4%
PIONEER, a high-resolution single-crystal polarized neutron diffractometer
Yaohua Liu, Huibo B. Cao, Stephan Rosenkranz, Matthew Frost, Thomas Huegle and 4 more
23 citationsOpen access (CC-BY)doi:10.1063/5.0089524OpenAlex
Show abstractHide abstract
PIONEER is a high Q-resolution, single-crystal, polarized neutron diffractometer at the Second Target Station (STS), Oak Ridge National Laboratory. It will provide the unprecedented capability of measuring tiny crystals (0.001 mm3, i.e., x-ray diffraction size), ultra-thin films (10 nm thickness), and weak structural and magnetic transitions. PIONEER benefits from the increased peak brightness of STS cold-neutron sources and uses advanced Montel mirrors that are able to deliver a focused beam with a high brilliance transfer, a homogeneous profile, and a low background. Monte Carlo simulations suggest that the optimized instrument has a high theoretical peak brilliance of 2.9 × 1012 n cm−2 sr−1 Å−1 s−1 at 2.5 Å at the sample position, within a 5 × 5 mm2 region and a ±0.3° divergence range. The moderator-to-sample distance is 60 m, providing a nominal wavelength band of 4.3 Å with a wavelength resolution better than 0.2% in the wavelength range of 1.0–6.0 Å. PIONEER is capable of characterizing large-scale periodic structures up to 200 Å. With a sample-to-detector distance of 0.8 m,…
- 32top 3.6%
Ambient pressure x-ray photoelectron spectroscopy setup for synchrotron-based in situ and operando atomic layer deposition research
Esko Kokkonen, Mikko Kaipio, Heta-Elisa Nieminen, Foqia Rehman, Ville Miikkulainen and 5 more
23 citationsOpen access (CC-BY)doi:10.1063/5.0076993OpenAlex
Show abstractHide abstract
An ambient pressure cell is described for conducting synchrotron-based x-ray photoelectron spectroscopy (XPS) measurements during atomic layer deposition (ALD) processes. The instrument is capable of true in situ and operando experiments in which it is possible to directly obtain elemental and chemical information from the sample surface using XPS as the deposition process is ongoing. The setup is based on the ambient pressure XPS technique, in which sample environments with high pressure (several mbar) can be created without compromising the ultrahigh vacuum requirements needed for the operation of the spectrometer and the synchrotron beamline. The setup is intended for chemical characterization of the surface intermediates during the initial stages of the deposition processes. The SPECIES beamline and the ALD cell provide a unique experimental platform for obtaining new information on the surface chemistry during ALD half-cycles at high temporal resolution. Such information is valuable for understanding the ALD reaction mechanisms and crucial in further developing and improving…
- 33top 3.7%
Diagnosing the pedestal magnetic field and magnetohydrodynamics radial structure with pedestal–scrape of layer electron cyclotron emission radiation inversion in H-mode plasma (invited)
Guanying Yu, Yilun Zhu, Max E. Austin, Ying Chen, J. Cao and 8 more
22 citationsdoi:10.1063/5.0099348OpenAlex
Show abstractHide abstract
Forward modeling is used to interpret inversion patterns of the pedestal–Scrape of Layer (SOL) Electron Cyclotron Emission (ECE) in DIII-D H-mode experiments. The modeling not only significantly improves the ECE data interpretation quality but also leads to the potential measurements of (1) the magnetic field strength |B| at the separatrix, (2) the pedestal |B| evolution during an inter-Edge Localized Mode (ELM) period, and (3) the pedestal Magnetohydrodynamics (MHD) radial structure. The ECE shine-through effect leads to three types of pedestal–SOL radiation inversions that are discussed in this paper. The first type of inversion is the non-monotonic Te,rad profile with respect to the major radius. Using the ECE frequency at the minimum Te,rad, the inversion can be applied to measure the magnetic field |B| at the separatrix and calibrate the mapping of the ECE channels with respect to the separatrix. The second type of inversion refers to the opposite phase between the radiation fluctuations δTe,rad at the pedestal and SOL. This δTe,rad phase inversion is sensitive to density and…
- 34top 3.8%
Instrument for measurement of interfacial structure–property relationships with decoupled interfacial shear and dilatational flow: “Quadrotrough”
Y. Summer Tein, Benjamin R. Thompson, Charles F. Majkrzak, Brian B. Maranville, Damian Renggli and 2 more
22 citationsOpen access (CC-BY)doi:10.1063/5.0090350OpenAlex
Show abstractHide abstract
Understanding the interfacial structure-property relationship of complex fluid-fluid interfaces is increasingly important for guiding the formulation of systems with targeted interfacial properties, such as those found in multiphase complex fluids, biological systems, biopharmaceuticals formulations, and many consumer products. Mixed interfacial flow fields, typical of classical Langmuir trough experiments, introduce a complex interfacial flow history that complicates the study of interfacial properties of complex fluid interfaces. In this article, we describe the design, implementation, and validation of a new instrument capable of independent application of controlled interfacial dilation and shear kinematics on fluid interfaces. Combining the Quadrotrough with both in situ Brewster angle microscopy and neutron reflectometry provides detailed structural measurements of the interface at the mesoscale and nanoscale in relationship to interfacial material properties under controlled interfacial deformation histories.
- 35top 3.9%
Evaluation of a new DIII-D Doppler backscattering system for higher wavenumber measurement and signal enhancement
J. Damba, Quinn Pratt, V. H. Hall-Chen, R. Hong, R. Lantsov and 2 more
21 citationsOpen accessdoi:10.1063/5.0101864OpenAlex
Show abstractHide abstract
The high density fluctuation poloidal wavenumber, kθ (kθ > 8 cm−1, kθρs > 5, ρs is the ion gyro radius using the ion sound velocity), measurement capability of a new Doppler backscattering (DBS) system at the DIII-D tokamak has been experimentally evaluated. In DBS, wavenumber (k) matching becomes more important at higher wavenumbers, owing to the exponential dependence of the measured signal loss factor on wave vector mismatch. Wave vector matching allows for the Bragg scattering condition to be satisfied, which minimizes the signal loss at higher k’s. In the previous DBS system, without toroidal wave vector matching, the measured DBS signal-to-noise ratio at higher kθ (>8 cm−1) is substantially reduced, making it difficult to measure higher kθ turbulence. The new DBS system has been optimized to access higher wavenumber, kθ ≤ 20 cm−1, density turbulence measurement. The optimization hardware addresses fluctuation wave vector matching using toroidal steering of the launch mirror to produce a backscattered signal with improved intensity. The probe’s sensitivity to high-k density…
- 36top 4%
Three-dimensional electron temperature measurement of inertial confinement fusion hotspots using x-ray emission tomography
Ka Wai Wong, B. Bachmann
21 citationsdoi:10.1063/5.0097471OpenAlex
Show abstractHide abstract
We present a novel approach to reconstruct three-dimensional (3D) electron temperature distributions of inertially confined fusion plasma hotspots at the National Ignition Facility. Using very limited number of two-dimensional (2D) x-ray imaging lines of sight, we perform 3D reconstructions of x-ray emission distributions from different x-ray energy channels ranging from 20 to 30 keV. 2D time-integrated x-ray images are processed using the algebraic reconstruction technique to reconstruct a 3D hotspot x-ray emission distribution that is self-consistent with the input images. 3D electron temperatures are computed using the energy channel ratios. We demonstrate the high accuracy and applicability of this method with different complex hotspot geometries in both synthetic and experimental results.
- 37top 4.1%
CHESS: The future direct geometry spectrometer at the second target station
Gabriele Sala, Martin Mourigal, Cristina Boone, Nicholas P. Butch, Andrew D Christianson and 12 more
21 citationsOpen access (CC-BY)doi:10.1063/5.0089740OpenAlex
Show abstractHide abstract
CHESS, chopper spectrometer examining small samples, is a planned direct geometry neutron chopper spectrometer designed to detect and analyze weak signals intrinsic to small cross sections (e.g., small mass, small magnetic moments, or neutron absorbing materials) in powders, liquids, and crystals. CHESS is optimized to enable transformative investigations of quantum materials, spin liquids, thermoelectrics, battery materials, and liquids. The broad dynamic range of the instrument is also well suited to study relaxation processes and excitations in soft and biological matter. The 15 Hz repetition rate of the Second Target Station at the Spallation Neutron Source enables the use of multiple incident energies within a single source pulse, greatly expanding the information gained in a single measurement. Furthermore, the high flux grants an enhanced capability for polarization analysis. This enables the separation of nuclear from magnetic scattering or coherent from incoherent scattering in hydrogenous materials over a large range of energy and momentum transfer. This paper presents…
- 38top 4.2%
High-heat flux ball-pen probe head in ASDEX-Upgrade
G. Grenfell, Jiřı́ Adámek, M. Komm, Dominik Brida, G. D. Conway and 8 more
21 citationsOpen access (CC-BY)doi:10.1063/5.0075846OpenAlex
Show abstractHide abstract
A new high heat flux ball-pen probe head installed on the midplane manipulator is currently being used in ASDEX-Upgrade (AUG). The probe was designed to withstand high heat fluxes making possible the investigation of the plasma edge under harsh conditions, such as low power H-mode. Composed of seven pins (four Langmuir probes, mounted in two Mach probe pairs, and three ball-pen probes), the new probe head allows us to measure several plasma parameters simultaneously and with high temporal resolution. A novel method to correct the sheath potential dynamically accounting for the total secondary electron emission is introduced together with applications to obtain the electron temperature and plasma potential profiles. The total secondary electron emission yield is obtained from particle in cell simulations in AUG condition and probe realistic impact angle with respect to the magnetic field. Finally, the probe capability to investigate turbulence around the separatrix of AUG is discussed.
- 39top 4.3%
System-on-chip approach microwave imaging reflectometer on DIII-D tokamak
Yilun Zhu, Ying Chen, Jo-Han Yu, C. W. Domier, Guanying Yu and 6 more
20 citationsOpen accessdoi:10.1063/5.0099170OpenAlex
Show abstractHide abstract
System-on-chip millimeter wave integrated circuit technology is used on the two-dimensional millimeter-wave imaging reflectometer (MIR) upgrade for density fluctuation imaging on the DIII-D tokamak fusion plasma. Customized CMOS chips have been successfully developed for the transmitter module and receiver module array, covering the 55-75 GHz working band. The transmitter module has the capability of simultaneously launching eight tunable probe frequencies (>0 dBm output power each). The receiver enclosure contains 12 receiver modules in two vertical lines. The quasi-optical local oscillator coupling of previous MIR systems has been replaced with an internal active frequency multiplier chain for improved local oscillator power delivery and flexible installation in a narrow space together with improved shielding against electromagnetic interference. The 55-75 GHz low noise amplifier, used between the receiver antenna and the first-stage mixer, significantly improves module sensitivity and suppresses electronics noise. The receiver module has a 20 dB gain improvement compared with the…
- 40top 4.4%
Design elements and first data from a new Doppler backscattering system on the MAST-U spherical tokamak
T. L. Rhodes, C. Michael, P. Shi, R. Scannell, S. Storment and 6 more
20 citationsOpen accessdoi:10.1063/5.0101848OpenAlex
Show abstractHide abstract
A new Doppler backscattering (DBS) system has been installed and tested on the MAST-U spherical tokamak. It utilizes eight simultaneous fixed frequency probe beams (32.5, 35, 37.5, 40, 42.5, 45, 47.5, and 50 GHz). These frequencies provide a range of radial positions from the edge plasma to the core depending on plasma conditions. The system utilizes a combination of novel features to provide remote control of the probed density wavenumber, the launched polarization (X vs O-mode), and the angle of the launched DBS to match the magnetic field pitch angle. The range of accessible density turbulence wavenumbers (kθ) is reasonably large with normalized wavenumbers kθρs ranging from ≤0.5 to 9 (ion sound gyroradius ρs = 1 cm). This wavenumber range is relevant to a variety of instabilities believed to be important in establishing plasma transport (e.g., ion temperature gradient, trapped electron, electron temperature gradient, micro-tearing, kinetic ballooning modes). The system is specifically designed to address the requirement of density fluctuation wavevector alignment which can…
- 41top 4.5%
Indirect inverse flux mapping of a concentrated solar source using infrared imaging
Mostafa Abuseada, Abdalla Alghfeli, Timothy S. Fisher
20 citationsdoi:10.1063/5.0090855OpenAlex
Show abstractHide abstract
With the growing interest in high-flux solar sources, a need exists for simple, accurate, and inexpensive strategies to characterize their output radiative flux. In this paper, the irradiation output from a 10 kWe xenon lamp solar simulator is characterized by an inverse mapping technique that uses a custom radiometer and infrared camera, validated by a direct characterization method (heat flux gauge). The heat flux distribution is determined in a vacuum chamber using an easily obtainable graphite target and an inverse heat transfer model. The solar simulator produces peak fluxes in the range of 1.5–4.5 MW/m2 as measured directly by a heat flux gauge, and its output can be controlled using a variable power supply. Spectral measurements indicate that minor variations in the simulator’s output with respect to its current supply occur in the spectral range of 450–800 nm. The radiometer presented in this work allows for characterizing solar irradiation under practical conditions (e.g., inside a solar reactor) and thus accounts for deviations due to additional components, such as…
- 42top 4.7%
THz microscope for three-dimensional imaging with superconducting Josephson junctions
Marco Tollkühn, Paul Julius Ritter, Meinhard Schilling, Benedikt Hampel
20 citationsdoi:10.1063/5.0084207OpenAlex
Show abstractHide abstract
Superconducting Josephson junctions have a wide range of applications ranging from quantum computing to voltage standards, and they may also be employed as versatile sensors for high-frequency radiation and magnetic fields. In this work, we present a unique measurement setup utilizing a single Josephson junction on a cantilever for high-resolution spatial measurements of spectroscopically resolved THz and microwave field distributions. This THz microscope can be utilized to measure power and frequency of electromagnetic radiation from ∼1 GHz to 5 THz. It may also be used to measure static magnetic fields and provide topological scans of samples. The samples can be both actively radiating or passively irradiated at either room temperature or cryogenic temperatures. We review the measurement setup of the THz microscope and describe the evaluation of its measurement data to achieve three-dimensional visualizations of the field distributions. The diverse capabilities of this unique tool are demonstrated by its different measurement modes with measurements of field distributions at 20…
- 43top 4.8%
Development of a cold target recoil ion momentum spectrometer and a projectile charge state analyzer setup to study electron transfer processes in highly charged ion–atom/molecule collisions
Md Abul Kalam Azad Siddiki, M. Nrisimhamurty, Kamal Kumar, Jibak Mukherjee, Lokesh C. Tribedi and 2 more
19 citationsdoi:10.1063/5.0100395OpenAlex
Show abstractHide abstract
We report the development and performance of a cold target recoil ion momentum spectrometer (COLTRIMS) setup at TIFR, which is built to study various atomic and molecular processes involving the interaction of slow, highly charged ions from an electron cyclotron resonance based ion accelerator. We give a detailed description of the experimental setup, as well as report some initial results on the electron-capture process in collisions of Ar8+ ions with helium and carbon monoxide targets. Here, we present the longitudinal momentum transfer and the sub-shell resolved Q-value spectrum in the case of 2, 4, and 6 keV/u Ar8+ beams in collision with helium. A longitudinal momentum resolution of 0.27 a.u. is achieved in the present system. We also report the state-selective scattering angle distributions for all the collision systems under investigation. We further discuss the fragmentation of the CO2+ molecular ions for different electron capture channels for the 5 keV/u Ar8+ beam. The combination of the COLTRIMS, along with the beam cleaner, the electrostatic deflectors, and the charge…
- 44top 4.9%
A haloscope amplification chain based on a traveling wave parametric amplifier
C. Braggio, Giulio Cappelli, G. Carugno, N. Crescini, R. Di Vora and 6 more
19 citationsOpen accessdoi:10.1063/5.0098039OpenAlex
Show abstractHide abstract
In this paper, we will describe the characterization of an RF amplification chain based on a traveling wave parametric amplifier. The detection chain is meant to be used for dark matter axion searches, and thus, it is coupled to a high Q microwave resonant cavity. A system noise temperature Tsys = (3.3 ± 0.1) K is measured at a frequency of 10.77 GHz, using a novel calibration scheme, allowing for measurement of Tsys exactly at the cavity output port.
- 45top 5%
Progress in in situ x-ray imaging of welding process
Xiaolin Zhang, Zijue Tang, Yi Xiong Wu, Oleg Devojno, Haowei Wang and 1 more
19 citationsdoi:10.1063/5.0074042OpenAlex
Show abstractHide abstract
Welding has been widely used in industry for hundreds of years, and pursuing higher weld quality requires a better understanding of the welding process. The x-ray imaging technique is a powerful tool to in situ observe the inner characteristics of the melt pool in the welding process. Here, current progress in in situ x-ray imaging of the welding process is concluded, including the experiments based on the laboratory-based single x-ray imaging system, the laboratory-based double x-ray imaging system, and the synchrotron radiation tomography system. The corresponding experimental results with the in situ x-ray imaging technique about the formation and evolution of the keyhole, melt pool, pore, solidification crack, etc., have been introduced. A new understanding of welding based on the current progress in in situ x-ray imaging of additive manufacturing is concluded. In addition, the future development trend of applying x-ray imaging technology in the field of monitoring the welding process is proposed.
- 46top 5.1%
Dual-axis thrust stand for the direct characterization of electrospray performance
Matthew Gilpin, Will A. McGehee, N. Ivan Arnold, Michael R. Natisin, Zachary A. Holley
19 citationsdoi:10.1063/5.0087716OpenAlex
Show abstractHide abstract
A dual-axis torsional thrust stand was successfully demonstrated at the Air Force Research Laboratory, enabling direct simultaneous thrust and mass loss measurement for the Air Force Electrospray Thruster Series 2 passively fed electrospray thruster. The dual-axis system is effectively two nulled torsional thrust stands sharing a single dual-axis gimbal with a thrust and mass resolution of ±0.2 µN and ±0.04 mg, respectively. The development of this system was inspired by a need for direct efficiency characterization of electrosprays via in situ mass measurements, and performance was compared to thruster masses measured pre- and post-testing using an analytical balance. Mass consumption data captured via the dual-axis stand, which is calibrated to a traceable uncertainty of 1.6%, varied between -5% and 18% as compared to analytical balance measurements throughout a multi-month testing effort highlighting the limitations in pre/post-weighing as a method for capturing propellant consumption due to absorption of atmospheric moisture when thrusters are removed from vacuum. Thrust stand…
- 47top 5.2%
A concept of a broadband inverted geometry spectrometer for the Second Target Station at the Spallation Neutron Source
Eugene Mamontov, Cristina Boone, Matthew Frost, Kenneth W. Herwig, Thomas Huegle and 6 more
19 citationsOpen access (CC-BY)doi:10.1063/5.0086451OpenAlex
Show abstractHide abstract
BWAVES is an acronym for Broadband Wide-Angle VElocity Selector spectrometer, indicating that a novel WAVES (Wide-Angle VElocity Selector) device will be used to select the velocity/wavelength of the detected neutrons after they are scattered by the sample. We describe a conceptual design of BWAVES, a time-of-flight broadband inverted-geometry neutron spectrometer for the Second Target Station at the Spallation Neutron Source operated by Oak Ridge National Laboratory. Being the first inverted geometry spectrometer where the energy of the detected neutrons can be chosen by a WAVES device mechanically, irrespective of the limitations imposed by the crystal analyzers or filters, BWAVES will feature a uniquely broad, continuous dynamic range of measurable energy transfers, spanning 4.5 decades. This will enable measurements of both vibrational and relaxational excitations within the same, continuous scattering spectra. Novel approaches that are necessary for the implementation of a WAVES device at the BWAVES spectrometer will result in a spectrometer with the design and characteristics…
- 48top 5.3%
Tunable cryogenic terahertz cavity for strong light–matter coupling in complex materials
Giacomo Jarc, Shahla Yasmin Mathengattil, Francesca Giusti, M. Barnaba, Abhishek Singh and 6 more
19 citationsOpen accessdoi:10.1063/5.0080045OpenAlex
Show abstractHide abstract
We report here the realization and commissioning of an experiment dedicated to the study of the optical properties of light–matter hybrids constituted of crystalline samples embedded in an optical cavity. The experimental assembly developed offers the unique opportunity to study the weak and strong coupling regimes between a tunable optical cavity in cryogenic environment and low energy degrees of freedom, such as phonons, magnons, or charge fluctuations. We describe here the setup developed that allows for the positioning of crystalline samples in an optical cavity of different quality factors, the tuning of the cavity length at cryogenic temperatures, and its optical characterization with a broadband time domain THz spectrometer (0.2–6 THz). We demonstrate the versatility of the setup by studying the vibrational strong coupling in CuGeO3 single crystal at cryogenic temperatures.
- 49top 5.4%
Anisotropic thermoreflectance thermometry: A contactless frequency-domain thermoreflectance approach to study anisotropic thermal transport
Luis Alberto Pérez, Kai Xu, Markus Raphael Wagner, Bernhard Dörling, Aleksandr Perevedentsev and 4 more
19 citationsOpen access (CC-BY)doi:10.1063/5.0066166OpenAlex
Show abstractHide abstract
We developed a novel contactless frequency-domain thermoreflectance approach to study thermal transport, which is particularly convenient when thermally anisotropic materials are considered. The method is based on a line-shaped heater geometry, produced with a holographic diffractive optical element, instead of using a spot heater as in conventional thermoreflectance. The heater geometry is similar to the one used in the 3-omega method, however, keeping all the technical advantages offered by non-contact methodologies. The present method is especially suitable to determine all the elements of the thermal conductivity tensor, which is experimentally achieved by simply rotating the sample with respect to the line-shaped optical heater. We provide the mathematical solution of the heat equation for the cases of anisotropic substrates, thin films, and multilayer systems. This methodology allows an accurate determination of the thermal conductivity and does not require complex modeling or intensive computational efforts to process the experimental data, i.e., the thermal conductivity is…
- 50top 5.5%
Diagnostics of RF coupling in H− ion sources as a tool for optimizing source design and operational parameters
S. Briefi, D. Zielke, David Rauner, U. Fantz
19 citationsOpen access (CC-BY)doi:10.1063/5.0077934OpenAlex
Show abstractHide abstract
ion sources are operated at very high power levels of up 100 kW in order to achieve the desired performance. For the experimental setup, these are demanding conditions possibly limiting the source reliability. Therefore, assessing the optimization potential in terms of RF power losses and the RF power transfer efficiency η to the plasma has moved to the focus of both experimental and numerical modeling investigations at particle accelerator and neutral beam heating sources for fusion plasmas. It has been demonstrated that, e.g., at typical neutral beam injection ion source setups, about half of the RF power provided by the generator is lost in the RF coil and the Faraday shield due to Joule heating or via eddy currents. In a best practice approach, it is exemplarily demonstrated at the ITER RF prototype ion source how experimental evaluation accompanied by numerical modeling of the ion source can be used to improve η. Individual optimization measures regarding the Faraday shield, the RF coil, the discharge geometry, the RF driving frequency, and the application of ferrites are…
How to read this list
The cohort is every article, review and book chapter OpenAlex attributes to Review of Scientific Instruments with publication year 2022, excluding retracted works and paratext such as editorials and errata. The top 50 by citation count are listed; the percentile is the rank divided by the cohort size. 50 of the 50 entries have an abstract in OpenAlex. Counts were read on 29 October 2026 and will not be updated on this page, so a quoted rank stays verifiable. Full rules on the methodology page.
Other journals, same idea
Work with these 25 papers in Kahubi
- The papers land in your library with their DOIs
- Ask anything across all of them, with citations
- Draft a literature review from the same sources
Free plan, no card. Your files stay private unless you share them.
Reading several of these?
Kahubi reads papers with you, keeps every citation traceable and drafts with sources you can check. Free plan, no card.