Most-cited articles · 2019

The 10 most-cited articles in Japanese Journal of Radiological Technology, 2019

Ranked by OpenAlex citation count on 29 October 2026, out of 174 eligible articles Japanese Journal of Radiological Technology published in 2019. Ranks are frozen; this page will not change. Number one, with 18 citations: 8. Image Processing Using ImageJ.

Cohort
174 articles
Listed
Top 10 (5.7%)
Open access
8 of 10
Snapshot
2026-10-29

The most-cited articles from this journal in 2019 cluster around image processing, radiation protection and dosimetry, and advanced CT techniques. The top paper, Mitsunori Goto's "Image Processing Using ImageJ," received 18 citations. It is followed by Toshioh Fujibuchi, Koki Ueda, Saki Kadoyanagi and colleagues' study on four-dimensional visualization of scatter distribution for radiation protection education using virtual reality, with 13 citations. Several other highly cited works address CT contrast protocols, radiomics for breast cancer classification, observer study software, and occupational radiation exposure.

Readers can use this list as a guide to the topics that attracted the most citation attention in the journal that year. The entries reflect a mix of methodological papers, educational tools, and clinical imaging studies. Citation counts offer one measure of influence, though they do not by themselves indicate quality or clinical importance.

Introduction written from the titles and abstracts on this list. Every figure below is the source.

Ask about these papers

Grounded in this list only, with sources.

3 of 3 free questions left today, no account needed
  1. 1
    top 0.6%

    8. Image Processing Using ImageJ

    Mitsunori Goto

    18 citationsdoi:10.6009/jjrt.2019_jsrt_75.7.688OpenAlex

  2. 2
    top 1.2%

    Examination of Application to Radiation Protection Education by Four-dimensional Visualization of Scatter Distribution in Radiological Examination Using Virtual Reality

    Toshioh Fujibuchi, Koki Ueda, Saki Kadoyanagi, Daiki Ueno, Chihiro Nakamura

    13 citationsOpen accessdoi:10.6009/jjrt.2019_jsrt_75.11.1297OpenAlex

    Show abstract

    PURPOSE: When working on fluoroscopy and patient assistance in a healthcare facility, workers need to understand how to properly protect scattered radiation. In this study, we examined a four-dimensional visualization method to make it easy to understand the spread of scattered radiation visually, and proposed its application to radiation protection education. METHODS: We constructed the X-ray room, X-ray CT room, and angiography room using Particle Heavy Ion Transport code System (PHITS), and calculated the scattered radiation distribution when the patient was irradiated with X-rays. The three-dimensional distribution of each moment was continuously displayed to create a four-dimensional distribution. Using the created data, we conducted radiation protection education including exercises to make the students confirm the scatter distribution from any direction. The effectiveness of the scattered radiation visualization data was evaluated by a questionnaire. RESULTS: The position of assistance for standing chest radiograph was less scattered radiation at the side and below the…

  3. 3
    top 1.8%

    Usefulness of Fenestrated Catheters for i.v. Contrast Infusion Cardiac CT Angiography for Newborn Patients during the Congenital Heart Disease

    Takayuki Yoshiura, Takanori Masuda, Yoriaki Matsumoto, Tomoyasu Sato, Yukari Yamashita and 5 more

    5 citationsOpen accessdoi:10.6009/jjrt.2019_jsrt_75.8.765OpenAlex

    Show abstract

    Purpose: A three-dimensional (3D) image from computed tomography (CT) angiography is a useful method for evaluation of complex anatomy such as congenital heart disease. However, 3D imaging requires high contrast enhancement for distinguishing between blood vessels and soft tissue. To improve the contrast enhancement, many are increasing the injection rate. However, one method is the use of fenestrated catheters, it allows use of a smaller gauge catheter for high-flow protocols. The purpose of this study was to compare the pressure of injection rate and CT number of a 24-gauge fenestrated catheter with an 22-gauge non-fenestrated catheter for i.v. contrast infusion during CT. Methods: Between December 2014 and March 2015, 50 newborn patients were randomly divided into two protocols; 22-gauge conventional non-fenestrated catheter (24 newborn; age range 0.25–8 months, body weight 3.6±1.2 kg) and 24-gauge new fenestrated catheter (22 newborn; age range 0.25–12 months, body weight 3.3±0.9 kg). Helical scan of the heart was performed using a 64-detector CT (LightSpeed VCT, GE Healthcare)…

  4. 4
    top 2.3%

    Selection of Radiomic Features for the Classification of Triple-negative Breast Cancer Based on Radiogenomics

    Chiharu Kai, Mako Ishimaru, Yoshikazu Uchiyama, Junji Shiraishi, Norimitsu Shinohara and 1 more

    4 citationsOpen accessdoi:10.6009/jjrt.2019_jsrt_75.1.24OpenAlex

    Show abstract

    Subtype classification of breast cancer by analyzing the gene expression profile of cancer cells is becoming a standard procedure. Breast cancer subtype classification is more useful than the conventional method because the characteristics of subtype classification is directly connected with the treatment method. However, genetic testing is invasive, and a part of cancer cells may not represent the overall nature of the cancer. In the computer-aided diagnosis (CAD) scheme for differentiation of triple-negative breast cancer (TNBC) by estimating the genetic properties of cancer based on Radiogenomics, principal component analysis (PCA) and least absolute shrinkage and selection operator (Lasso) were used for reducing the dimension of radiomic features, and we compared usefulness of both. We collected 81 magnetic resonance (MR) images, which included 30 TNBC and 51 others, from the public database. From the MR slice images, we selected the slice containing the largest area of the cancer and manually marked the cancer region. We subsequently calculated 294 radiomic features in the…

  5. 5
    top 2.9%

    Image Evaluation with Paired Comparison Method Using Automatic Analysis Software: Comparison of CT Images with Simulated Levels of Exposure Dose

    Junji Shiraishi, Yuuka Okazaki, Makoto Goto

    4 citationsOpen accessdoi:10.6009/jjrt.2019_jsrt_75.1.32OpenAlex

    Show abstract

    To simplify a procedure of the observer study with Ura's method of Scheffé's paired comparison and to improve experimental accuracy, we developed a software package to automatically analyze observer study data obtained by using a computer interface developed specially for the ROC observer study. Simulated low-dose CT images were used to demonstrate practical utility of this proposed method with a software package, in terms of a statistical analysis of the change of noise property due to the change of exposure dose. Six radiological technologists were participated in this observer study and compared each of six sample images selected at lower lung and liver slices with dose levels of 100, 80, 60, 40, 20, 10% per case. In the statistical analysis, the average psychological measures were highly correlated with the dose levels (lower lungs: R=0.95, liver: R=0.99). In addition, there were statistically significant differences in all combination of dose levels in liver slices. In conclusion, we demonstrated practical utility of this proposed method in terms of simplification of…

  6. 6
    top 3.5%

    Measurement of Head and Neck Exposure in CT Guided IVR

    Takafumi Iizuka, Kazuma Matsumoto, Yoshiaki Hagihara, Toshiya Nasada, Youko Ikeuchi and 7 more

    4 citationsOpen accessdoi:10.6009/jjrt.2019_jsrt_75.7.625OpenAlex

    Show abstract

    In April 2011, the International Radiological Protection Committee recommended that "The equivalent dose of the crystalline lens should not exceed 20 mSv/year, averaged over defined periods of 5 years, with no single year exceeding 50 mSv". Based on this recommendation, it is predicted that the equivalent dose limit of our crystalline lens can be lowered in the near future. Therefore, it is important to grasp the current situation of radiation exposure. The purpose of this study is to measure the crystalline lens of surgeons by focusing on the CT-fluoroscopy guided interventional radiology's (IVRs). We also examined whether the exposure dose of the crystalline lens can be correctly evaluated by measuring the unequal exposure dose of the neck, which is usually used for the unequal exposure measurement. Results of the analysis of 200 CT-fluoroscopy guided IVR procedures showed that the unequal exposure dose of the neck was significantly correlated with the exposure dose of the crystalline lens which was measured near the left eye ball (R=0.83). However, the exposure dose of the…

  7. 7
    top 4.1%

    Impact of Misregistration between the Myocardial Perfusion Images and CT Attenuation Correction Map on the %up Take with 17 Segments Polar Map

    Kenta Yoshikawa, Taiki Chono, Osamu Asanuma, Naoya Yama

    4 citationsOpen accessdoi:10.6009/jjrt.2019_jsrt_75.9.892OpenAlex

    Show abstract

    PURPOSE: Computed tomography (CT) attenuation correction of myocardial perfusion in single-photon emission computed tomography (SPECT) /CT systems is possibility of misregistration between emission and transmission scans. This study aimed to evaluate the influence of misregistration using a polar map of 17 segments model. METHODS: Tc) tetrofosmin. After registration, CT data was shifted by ±1, ±2, and ±3 pixels along the cephalad/caudal, dorsal/ventral, and left/right axes, respectively. The registered image was compared with the shifted image. RESULTS: Misregistration between the SPECT and CT images occurred by 1-2 pixels in 127 cases (63.5%) and by 2 or more pixels in four cases (2%); the maximum misregistration was 1.2±0.4 pixels on average. The polar map scoring was most significantly affected by 3 pixel ventral shift. A ventral shift of 1 pixel affected the scores for the anterolateral and inferolateral segments, whereas a caudal shift of 1 pixel affected the scores for the anterior segment. CONCLUSION: Since the 17 segments model can evaluate the position more precisely than…

  8. 8
    top 4.6%

    Radiation Exposure in Computed Tomography Localizer Radiograph

    Toshimitsu Sato, Yuho Kikuchi, Masataka Nakamura, N. Saito, Y Arai

    4 citationsOpen accessdoi:10.6009/jjrt.2019_jsrt_75.12.1403OpenAlex

    Show abstract

    This research measured the radiation exposure of the computed tomography(CT) localizer radiograph of the trunk of the body. The entrance surface dose for CT localizer radiograph was measured using radiophotoluminescent glass dosimeter(RPLD) on four points of measurement, including the center of the phantom, on the surface of a phantom placed in the center of a CT bed, assuming that the subject has a thickness of 20 cm. The entrance surface dose of the localizer radiograph under the chest CT protocol manufacturer's initial setting conditions of 120 kV 35 mA was 0.80 mGy at the center and 0.53 for the 4-location average for the upper X-ray tube (excluding the CT bed), and 0.74 mGy at the center and 0.48 mGy for the 4-location average for the lower X-ray tube (including the CT bed). Compared to the Japan DRLs 2015 chest X-ray (P→A), the entrance surface dose was 2.67 times at the center and 1.77 times for the 4-location average for the upper X-ray tube and 2.47 times at the center and 1.60 times for the 4-location average for the lower X-ray tube. The CT radiation dose also cannot be…

  9. 10
    top 5.8%

    Utility of Split-bolus Single-phase Protocol for Pulmonary Artery and Vein Separation Preoperative 3D-CTA in Lung Cancer Video-assisted Thoracic Surgery

    Tetsuya Kitano, Masakazu Kaneko, Shigeki Yamada

    3 citationsOpen accessdoi:10.6009/jjrt.2019_jsrt_75.10.1165OpenAlex

    Show abstract

    There are many variations in branching and running of pulmonary artery (PA) and pulmonary vein (PV). It is desirable to separate as a surgical simulation of lung cancer and important to grasp before video-assisted thoracic surgery (VATS) to perform quick and safe. Therefore, the purpose of this study was to evaluate objective and subjective image quality (contrast attenuation, separation ability, and vascular visualization) of PA and PV of splitbolus single-phase protocol (SBSPP) in preoperative three-dimensional computed tomography angiography (3DCTA). CT value of PA was 410.2±71.0 Hounsfield unit (HU), PV was 245.1±24.8 HU, difference between CT value of PA and CT value of PV was 164.5±60.9 HU. Subjective image quality of PA and PV could be visualized until more than the segmental branch level. SBSPP can obtain sufficient CT value for separate visualization of PA and PV, and before VATS useful PA and PV 3D-CTA imaging.

How to read this list

The cohort is every article, review and book chapter OpenAlex attributes to Japanese Journal of Radiological Technology with publication year 2019, excluding retracted works and paratext such as editorials and errata. The top 10 by citation count are listed; the percentile is the rank divided by the cohort size. 8 of the 10 entries have an abstract in OpenAlex. Counts were read on 29 October 2026 and will not be updated on this page, so a quoted rank stays verifiable. Full rules on the methodology page.

Other journals, same idea

Work with these 10 papers in Kahubi

  • The papers land in your library with their DOIs
  • Ask anything across all of them, with citations
  • Draft a literature review from the same sources

Free plan, no card. Your files stay private unless you share them.

Reading several of these?

Kahubi reads papers with you, keeps every citation traceable and drafts with sources you can check. Free plan, no card.