Most-cited articles · 2018

The 10 most-cited articles in Japanese Journal of Radiological Technology, 2018

Ranked by OpenAlex citation count on 29 October 2026, out of 168 eligible articles Japanese Journal of Radiological Technology published in 2018. Ranks are frozen; this page will not change. Number one, with 38 citations: Explanation of JIS T 62570 Standard Practice for Marking Medical Devices and Other Items for Safety in the Magnetic Resonance Environment.

Cohort
168 articles
Listed
Top 10 (6.0%)
Open access
8 of 10
Snapshot
2026-10-29

The most-cited articles from the Japanese Journal of Radiological Technology in 2018 cluster around a few themes: magnetic resonance safety standards, radiation exposure and dose estimation in computed tomography, and image quality assessment. The top paper, Toru Shimizu's explanation of JIS T 62570 on marking medical devices for safety in the magnetic resonance environment, leads with 38 citations. Other highly cited works address techniques to reduce staff radiation exposure during CT assistance, a relative artifact index for evaluating streak artifacts, and a phantom for diffusion-weighted imaging of small acute-phase cerebral infarction.

Readers can use this list to see which topics attracted the most citation attention in the journal that year. The ranking reflects citation counts from OpenAlex out of 168 eligible articles and does not by itself indicate quality or clinical importance. Titles and abstracts provide the basis for each entry, and fuller details require consulting the original articles.

Introduction written from the titles and abstracts on this list. Every figure below is the source.

Ask about these papers

Grounded in this list only, with sources.

3 of 3 free questions left today, no account needed
  1. 2
    top 1.2%

    Effective Techniques to Reduce Radiation Exposure to Medical Staff during Assist of X-ray Computed Tomography Examination

    Ryuichi Miyajima, Toshioh Fujibuchi, Yusuke Miyachi, Satoshi Tateishi, Yoshinori Uno and 3 more

    9 citationsOpen accessdoi:10.6009/jjrt.2018_jsrt_74.4.326OpenAlex

    Show abstract

    Medical staffs like radiological technologists, doctors, and nurses are at an increased risk of exposure to radiation while assisting the patient in a position or monitor contrast medium injection during computed tomography (CT). However, methods to protect medical staff from radiation exposure and protocols for using radiological protection equipment have not been standardized and differ among hospitals. In this study, the distribution of scattered X-rays in a CT room was measured by placing electronic personal dosimeters in locations where medical staff stands beside the CT scanner gantry while assisting the patient and the exposure dose was measured. Moreover, we evaluated non-uniform exposure and revealed effective techniques to reduce the exposure dose to medical staff during CT. The dose of the scattered X-rays was the lowest at the gantry and at the examination table during both head and abdominal CT. The dose was the highest at the trunk of the upper body of the operator corresponding to a height of 130 cm during head CT and at the head corresponding to a height of 150 cm…

  2. 3
    top 1.8%

    Suggestion of the Relative Artifact Index for Noise-independent Evaluation of the Streak Artifact

    Ken Takada, Katsuhiro Ichikawa, Shinnya Banno, Katsuhiko Otobe

    9 citationsOpen accessdoi:10.6009/jjrt.2018_jsrt_74.4.315OpenAlex

    Show abstract

    The aim of this study was to inspect the usefulness of relative artifact index (AIr), which divided artifact index (AI) by standard deviation of the noise image for noise-independent evaluation of the streak artifact in computed tomography images. A water phantom without/with a cylindrical phantom filled with diluted contrast medium was scanned with different tube voltages (100/120/140 kV) and radiation doses (5/10/20 mGy), then images were reconstructed with different kernels (B10/30/50f). AI, location parameter in Gumbel method and AIr were measured in each condition and compared. The higher tube voltage or radiation dose or lower spatial resolution kernel, the lower quantitative values were presented by both AI and Gumbel method. AIr showed quantitative values independent of radiation dose and kernel, and substantial artifact amounts affected only by tube voltage. Our results showed AIr can evaluate quantitative artifact amount independent of image noise.

  3. 4
    top 2.4%

    Preparation of a Small Acute-phase Cerebral Infarction Phantom for Diffusion-weighted Imaging

    Masahiko Takahashi, Maiko Hashimoto, Masumi Uehara

    9 citationsOpen accessdoi:10.6009/jjrt.2018_jsrt_74.6.531OpenAlex

    Show abstract

    The present study aimed to prepare a small acute-phase cerebral infarction phantom made of gelatin and sucrose to simulate brain parenchymal cells, and a phantom made of collagen peptides and sucrose to simulate cerebral infarction for diffusion-weighted imaging (DWI). During the preparation of gelatin and sucrose mixture (17.0 wt% gelatin, 20.0 wt% sucrose), a cylindrical wooden bar was placed in the center of the phantom and covered with a heat-shrinkable film to ensure space remained after gelling. A mixed solution composed of collagen peptide and sucrose (16.0 wt% collagen peptide, 27.5 wt% sucrose) was then enclosed within the space. The T2 relaxation time and apparent diffusion coefficient (ADC) of the phantom were set equal to those observed in actual patients with acute-phase cerebral infarction. The mixture was selected based on the signal intensity of both the healthy brain tissue and that subjected to acute cerebral infarction, such that no contrast was observed during T2-weighted imaging (T2WI). T2WI and DWI were performed using a 1.5 T scanner. Although contrast between…

  4. 5
    top 3%

    7. Radiation Therapy for Prostate Cancer

    Tomohiko Tanino, Nobue Uchida

    7 citationsdoi:10.6009/jjrt.2018_jsrt_74.1.84OpenAlex

  5. 6
    top 3.6%

    Comparison of Organ Dose Calculation Using Monte Carlo Simulation and In-phantom Dosimetry in CT Examination

    Akiko Iriuchijima, Yasuhiro Fukushima, Akio Ogura

    7 citationsOpen accessdoi:10.6009/jjrt.2018_jsrt_74.2.166OpenAlex

    Show abstract

    Direct measurement of each patient organ dose from computed tomography (CT) is not possible. Most methods to estimate patient organ dose is using Monte Carlo simulation with dedicated software. However, the method and the relative differences between organ dose simulation and measurement is unclear. The purpose of this study was to compare organ doses evaluated by Monte Carlo simulation with doses evaluated by in-phantom dosimetry. The simulation software Radimetrics (Bayer) was used for the calculation of organ dose. Measurement was performed with radio-photoluminescence glass dosimeter (RPLD) set at various organ positions within RANDO phantom. To evaluate difference of CT scanner, two different CT scanners were used in this study. Angular dependence of RPLD and measurement of effective energy were performed for each scanner. The comparison of simulation and measurement was evaluated by relative differences. In the results, angular dependence of RPLD at two scanners was 31.6±0.45 mGy for SOMATOM Definition Flash and 29.2±0.18 mGy for LightSpeed VCT. The organ dose was 42.2 mGy…

  6. 7
    top 4.2%

    Effect of Misregistration between SPECT and CT Images on Attenuation Correction for Quantitative Bone SPECT Imaging

    Mika Sakoshi, Norikazu Matsutomo, Tomoaki Yamamoto, Eisuke Sato

    6 citationsOpen accessdoi:10.6009/jjrt.2018_jsrt_74.5.452OpenAlex

    Show abstract

    Purpose: The aim of this study was to evaluate the effect of misregistration between single-photon emission computed tomography (SPECT) and computed tomography (CT) images on bone SPECT. Methods: We acquired SPECT and CT images of a body phantom filled with bone-equivalent solution and 99mTc for evaluation of bone SPECT. SPECT images were reconstructed using attenuation correction maps obtained by shifting the attenuation coefficients from non-shifted values (reference). Activity concentrations, SPECT standardized uptake values (SPECT-SUVs), and tumor background ratios (TBRs) were evaluated. Results: Activity concentrations and SPECT-SUVs decreased with decreasing attenuation coefficient. The difference in attenuation coefficient was especially large between the shifted-to-lung (0.085 cm−1) and reference (0.249 cm−1) values. Non-shifted and shifted-to-lung SPECT-SUVs were 11.5±1.0 and 2.3±0.2, respectively. TBR also decreased with decreasing attenuation coefficient. The maximum percentage change in TBR was 86% in the shifted-to-lung value. Conclusions: Our results indicate that the…

  7. 8
    top 4.8%

    Evaluation of Organ Dose Estimation from Indices of CT Dose Using Dose Index Registry

    Akiko Iriuchijima, Yasuhiro Fukushima, Akio Ogura

    5 citationsOpen accessdoi:10.6009/jjrt.2018_jsrt_74.1.22OpenAlex

    Show abstract

    Direct measurement of each patient organ dose from computed tomography (CT) is not possible. Most methods to estimate patient organ dose is using Monte Carlo simulation with dedicated software. However, dedicated software is too expensive for small scale hospitals. Not every hospital can estimate organ dose with dedicated software. The purpose of this study was to evaluate the simple method of organ dose estimation using some common indices of CT dose. The Monte Carlo simulation software Radimetrics (Bayer) was used for calculating organ dose and analysis relationship between indices of CT dose and organ dose. Multidetector CT scanners were compared with those from two manufactures (LightSpeed VCT, GE Healthcare; SOMATOM Definition Flash, Siemens Healthcare). Using stored patient data from Radimetrics, the relationships between indices of CT dose and organ dose were indicated as each formula for estimating organ dose. The accuracy of estimation method of organ dose was compared with the results of Monte Carlo simulation using the Bland-Altman plots. In the results, SSDE was the…

  8. 9
    top 5.4%

    Measurement Accuracy of Fat and Iron Deposits in the Liver Using 1H-MRS (HISTO)

    Yuuki Yoshimura, Daisuke Suzuki, Kanae Miyahara

    4 citationsOpen accessdoi:10.6009/jjrt.2018_jsrt_74.2.148OpenAlex

    Show abstract

    1H-MRS, which is a method of measuring fat and iron deposits in the liver, has a single voxel spectroscopy imaging method called high-speed T2-corrected multiecho (HISTO) based on the STEAM method. If HISTO measurement accuracy is high, it will be one of the biomarkers, so the measurement accuracy was examined. We imaged a self-made phantom simulating a known amount of fat and iron deposition in the liver. A regression analysis of HISTO-measured values for hepatic fat phantom was performed. In addition, regression analysis was performed on the hepatic iron phantom for the R2 values obtained from the T2 values measurement and the actually measured value of the HISTO. From the regression analysis, the correlation coefficients were 0.999, 0.992 and 0.977, respectively. The measurement accuracy of HISTO is high, and the reliability of the obtained fat and iron deposit value is high.

  9. 10
    top 6%

    The Measurement Precision and Accuracy of T1 Mapping Using Polarity Corrected (PC) TI Prep Tool

    Hironobu Ishikawa, Shinya Seino, Hideaki Takasumi, Katsuyuki Kikori, Masahiro Harata and 5 more

    4 citationsOpen accessdoi:10.6009/jjrt.2018_jsrt_74.1.13OpenAlex

    Show abstract

    The aim of this study was to evaluate the measurement precision and accuracy of T1 mapping using a polarity corrected (PC) TI prep tool, which was based on fast field echo (FFE) and obtained one data point with one inversion recovery (IR) pulse. A phantom was used consisting of eight materials with different Gd concentrations. T1 mappings were measured by changing the trigger interval and the inversion time (TI) interval. The T1 mapping measurement precision using the PC TI prep tool increased as the trigger interval was made longer. The measurement precision didn’t depend on the interval of TI. On the other hand, when the trigger intervals are more than 1000 ms, the measurement accuracy was less than approximately 8%. By setting the optimal end of TI, the T1 mapping using a PC TI prep tool could measure the T1 value precisely and accurately.

How to read this list

The cohort is every article, review and book chapter OpenAlex attributes to Japanese Journal of Radiological Technology with publication year 2018, excluding retracted works and paratext such as editorials and errata. The top 10 by citation count are listed; the percentile is the rank divided by the cohort size. 8 of the 10 entries have an abstract in OpenAlex. Counts were read on 29 October 2026 and will not be updated on this page, so a quoted rank stays verifiable. Full rules on the methodology page.

Other journals, same idea

Work with these 10 papers in Kahubi

  • The papers land in your library with their DOIs
  • Ask anything across all of them, with citations
  • Draft a literature review from the same sources

Free plan, no card. Your files stay private unless you share them.