Most-cited articles · 2024

The 50 most-cited articles in Analytical and Bioanalytical Chemistry, 2024

Ranked by OpenAlex citation count on 29 October 2026, out of 558 eligible articles Analytical and Bioanalytical Chemistry published in 2024. Ranks are frozen; this page will not change. Number one, with 78 citations: Recent developments and challenges in resistance-based hydrogen gas sensors based on metal oxide semiconductors.

Cohort
558 articles
Listed
Top 50 (9.0%)
Open access
33 of 50
Snapshot
2026-10-29

The most-cited articles from Analytical and Bioanalytical Chemistry in 2024 cluster around several themes. Sensor research features prominently, including resistance-based hydrogen gas sensors and wearable sweat glucose detection. Environmental analysis is also well represented, with non-target screening in water and PFAS detection drawing substantial attention. The top paper, by Lili Gao, Ye Tian, Altaf Hussain and colleagues, is a review of resistance-based hydrogen gas sensors using metal oxide semiconductors, with 78 citations.

Readers can use this list to identify the topics and article types that attracted the most citations in the journal in 2024. The ranking reflects citation counts from OpenAlex across 558 eligible articles and offers a neutral snapshot of which reviews and research papers were most frequently referenced in the literature.

Introduction written from the titles and abstracts on this list. Every figure below is the source.

Ask about these papers

Grounded in this list only, with sources.

3 of 3 free questions left today, no account needed
  1. 1
    top 0.2%
  2. 2
    top 0.4%

    NMR spectroscopy for metabolomics in the living system: recent progress and future challenges

    Yun Fei Peng, Zeting Zhang, Lichun He, Conggang Li, Maili Liu

    57 citationsOpen access (CC-BY)doi:10.1007/s00216-024-05137-8OpenAlex

    Show abstract

    Metabolism is a fundamental process that underlies human health and diseases. Nuclear magnetic resonance (NMR) techniques offer a powerful approach to identify metabolic processes and track the flux of metabolites at the molecular level in living systems. An in vitro study through in-cell NMR tracks metabolites in real time and investigates protein structures and dynamics in a state close to their most natural environment. This technique characterizes metabolites and proteins involved in metabolic pathways in prokaryotic and eukaryotic cells. In vivo magnetic resonance spectroscopy (MRS) enables whole-organism metabolic monitoring by visualizing the spatial distribution of metabolites and targeted proteins. One limitation of these NMR techniques is the sensitivity, for which a possible improved approach is through isotopic enrichment or hyperpolarization methods, including dynamic nuclear polarization (DNP) and parahydrogen-induced polarization (PHIP). DNP involves the transfer of high polarization from electronic spins of radicals to surrounding nuclear spins for signal…

  3. 3
    top 0.6%

    Non-target screening in water analysis: recent trends of data evaluation, quality assurance, and their future perspectives

    Maryam Vosough, Torsten Claus Schmidt, Gerrit Renner

    53 citationsOpen access (CC-BY)doi:10.1007/s00216-024-05153-8OpenAlex

    Show abstract

    This trend article provides an overview of recent advancements in Non-Target Screening (NTS) for water quality assessment, focusing on new methods in data evaluation, qualification, quantification, and quality assurance (QA/QC). It highlights the evolution in NTS data processing, where open-source platforms address challenges in result comparability and data complexity. Advanced chemometrics and machine learning (ML) are pivotal for trend identification and correlation analysis, with a growing emphasis on automated workflows and robust classification models. The article also discusses the rigorous QA/QC measures essential in NTS, such as internal standards, batch effect monitoring, and matrix effect assessment. It examines the progress in quantitative NTS (qNTS), noting advancements in ionization efficiency-based quantification and predictive modeling despite challenges in sample variability and analytical standards. Selected studies illustrate NTS's role in water analysis, combining high-resolution mass spectrometry with chromatographic techniques for enhanced chemical exposure…

  4. 5
    top 0.9%

    Carbon-based nanozymes: design, catalytic mechanisms, and environmental applications

    Zheqi Zhuang, Yanni Yu, Shipeng Dong, Xiaolin Sun, Liang Mao

    50 citationsdoi:10.1007/s00216-024-05405-7OpenAlex

  5. 6
    top 1.1%

    The 2023 Nobel Prize in Chemistry: Quantum dots

    K. David Wegner, Ute Resch‐Genger

    46 citationsOpen access (CC-BY)doi:10.1007/s00216-024-05225-9OpenAlex

    Show abstract

    The 2023 Nobel Prize in Chemistry was awarded to Aleksey I. Ekimov (prize share 1/3), Louis E. Brus (prize share 1/3), and Moungi G. Bawendi (prize share 1/3) for groundbreaking inventions in the field of nanotechnology, i.e., for the discovery and synthesis of semiconductor nanocrystals, also termed quantum dots, that exhibit size-dependent physicochemical properties enabled by quantum size effects. This feature article summarizes the main milestones of the discoveries and developments of quantum dots that paved the road to their versatile applications in solid-state lighting, display technology, energy conversion, medical diagnostics, bioimaging, and image-guided surgery.

  6. 7
    top 1.3%

    Artificial intelligence-based plasma exosome label-free SERS profiling strategy for early lung cancer detection

    Dechan Lu, Zhikun Shangguan, Zhehao Su, Lin Chuan, Zufang Huang and 1 more

    44 citationsdoi:10.1007/s00216-024-05445-zOpenAlex

  7. 8
    top 1.5%

    Critical review on in silico methods for structural annotation of chemicals detected with LC/HRMS non-targeted screening

    Henrik Hupatz, Ida Rahu, Wei‐Chieh Wang, Pilleriin Peets, Emma Helena Palm and 1 more

    43 citationsOpen access (CC-BY)doi:10.1007/s00216-024-05471-xOpenAlex

    Show abstract

    Non-targeted screening with liquid chromatography coupled to high-resolution mass spectrometry (LC/HRMS) is increasingly leveraging in silico methods, including machine learning, to obtain candidate structures for structural annotation of LC/HRMS features and their further prioritization. Candidate structures are commonly retrieved based on the tandem mass spectral information either from spectral or structural databases; however, the vast majority of the detected LC/HRMS features remain unannotated, constituting what we refer to as a part of the unknown chemical space. Recently, the exploration of this chemical space has become accessible through generative models. Furthermore, the evaluation of the candidate structures benefits from the complementary empirical analytical information such as retention time, collision cross section values, and ionization type. In this critical review, we provide an overview of the current approaches for retrieving and prioritizing candidate structures. These approaches come with their own set of advantages and limitations, as we showcase in the…

  8. 9
    top 1.7%

    Recent advances in near-infrared I/II persistent luminescent nanoparticles for biosensing and bioimaging in cancer analysis

    Ming‐Hsien Chan, Yu‐Chan Chang

    43 citationsOpen access (CC-BY)doi:10.1007/s00216-024-05267-zOpenAlex

    Show abstract

    Photoluminescent materials (PLNs) are photoluminescent materials that can absorb external excitation light, store it, and slowly release it in the form of light in the dark to achieve long-term luminescence. Developing near-infrared (NIR) PLNs is critical to improving long-afterglow luminescent materials. Because they excite in vitro, NIR-PLNs have the potential to avoid interference from in vivo autofluorescence in biomedical applications. These materials are promising for biosensing and bioimaging applications by exploiting the near-infrared biological window. First, we discuss the biomedical applications of PLNs in the first near-infrared window (NIR-I, 700-900 nm), which have been widely developed and specifically introduce biosensors and imaging reagents. However, the light in this area still suffers from significant light scattering and tissue autofluorescence, which will affect the imaging quality. Over time, fluorescence imaging technology in the second near-infrared window (NIR-II, 1000-1700 nm) has also begun to develop rapidly. NIR-II fluorescence imaging has the…

  9. 10
    top 1.8%

    A Dual-mode platform for the rapid detection of Escherichia coli O157:H7 based on CRISPR/Cas12a and RPA

    Jiawei Luo, Danhong Xu, Jinbin Wang, Hua Liu, You Li and 4 more

    40 citationsdoi:10.1007/s00216-024-05301-0OpenAlex

  10. 11
    top 2%

    Wearable biosensors for human sweat glucose detection based on carbon black nanoparticles

    Chaoli Tang, Kai Zhou, Rujing Wang, Mengya Li, Wenlong Liu and 4 more

    40 citationsdoi:10.1007/s00216-024-05135-wOpenAlex

  11. 12
    top 2.2%

    Trends in surface plasmon resonance biosensing: materials, methods, and machine learning

    Daniel D. Stuart, Westley Van Zant, Santino N. Valiulis, Alexander S. Malinick, Victor A. Hanson and 1 more

    39 citationsOpen accessdoi:10.1007/s00216-024-05367-wOpenAlex

  12. 13
    top 2.4%

    Challenges faced with 3D-printed electrochemical sensors in analytical applications

    Lauro Antonio Pradela Filho, Diele A. G. Araújo, Vanessa N. Ataide, Gabriel N. Meloni, Thiago R. L. C. Paixão

    36 citationsdoi:10.1007/s00216-024-05308-7OpenAlex

  13. 14
    top 2.6%

    Application of gold nanoclusters in fluorescence sensing and biological detection

    Kexin Tan, Huizhen Ma, Xiaoyu Mu, Zhidong Wang, Qi Wang and 2 more

    35 citationsdoi:10.1007/s00216-024-05220-0OpenAlex

  14. 15
    top 2.7%

    Establishing performance metrics for quantitative non-targeted analysis: a demonstration using per- and polyfluoroalkyl substances

    Shirley Pu, James P. McCord, Jacqueline Bangma, Jon R. Sobus

    35 citationsOpen access (CC-BY)doi:10.1007/s00216-023-05117-4OpenAlex

    Show abstract

    Non-targeted analysis (NTA) is an increasingly popular technique for characterizing undefined chemical analytes. Generating quantitative NTA (qNTA) concentration estimates requires the use of training data from calibration "surrogates," which can yield diminished predictive performance relative to targeted analysis. To evaluate performance differences between targeted and qNTA approaches, we defined new metrics that convey predictive accuracy, uncertainty (using 95% inverse confidence intervals), and reliability (the extent to which confidence intervals contain true values). We calculated and examined these newly defined metrics across five quantitative approaches applied to a mixture of 29 per- and polyfluoroalkyl substances (PFAS). The quantitative approaches spanned a traditional targeted design using chemical-specific calibration curves to a generalizable qNTA design using bootstrap-sampled calibration values from "global" chemical surrogates. As expected, the targeted approaches performed best, with major benefits realized from matched calibration curves and internal standard…

  15. 17
    top 3.1%

    Determination of per- and polyfluoroalkyl substances (PFAS) in six different fish species from Swiss lakes

    Mylène Soudani, Lucie Hegg, Camille Rime, Camille Coquoz, Denise Bussien Grosjean and 4 more

    33 citationsOpen access (CC-BY)doi:10.1007/s00216-024-05524-1OpenAlex

    Show abstract

    Per- and polyfluoroalkyl substances (PFAS) are persistent environmental contaminants with bioaccumulation potential, particularly affecting aquatic ecosystems and human health also via fish consumption. There is therefore a need for reliable extraction methods and studies to accurately assess PFAS levels in fish, crucial for understanding bioaccumulation and potential toxicological effects on both fish and humans through consumption. This study investigated PFAS levels in freshwater fish from Swiss lakes, focusing on six common species: Coregonus wartmanni, Cyprinus carpio, Oncorhynchus mykiss, Perca fluviatilis, Salmo trutta, and Squalius cephalus. Utilizing an optimized QuEChERS extraction method, 15 PFAS were analyzed in 218 fish fillet samples using liquid chromatography-mass spectrometry (LC-MS/MS). The results were compared to EU regulations and EFSA guidelines for tolerable weekly intake (TWI), with a specific focus on correlations between fish size and PFAS concentration. Our findings reveal significant PFAS contamination, particularly in Perca fluviatilis with…

  16. 18
    top 3.3%

    Progress, applications, and challenges in high-throughput effect-directed analysis for toxicity driver identification — is it time for HT-EDA?

    Iker Alvarez-Mora, Katarzyna Arturi, Frederic M. Béen, Sebastian Buchinger, Abd El Rahman El Mais and 11 more

    33 citationsOpen access (CC-BY)doi:10.1007/s00216-024-05424-4OpenAlex

    Show abstract

    The rapid increase in the production and global use of chemicals and their mixtures has raised concerns about their potential impact on human and environmental health. With advances in analytical techniques, in particular, high-resolution mass spectrometry (HRMS), thousands of compounds and transformation products with potential adverse effects can now be detected in environmental samples. However, identifying and prioritizing the toxicity drivers among these compounds remain a significant challenge. Effect-directed analysis (EDA) emerged as an important tool to address this challenge, combining biotesting, sample fractionation, and chemical analysis to unravel toxicity drivers in complex mixtures. Traditional EDA workflows are labor-intensive and time-consuming, hindering large-scale applications. The concept of high-throughput (HT) EDA has recently gained traction as a means of accelerating these workflows. Key features of HT-EDA include the combination of microfractionation and downscaled bioassays, automation of sample preparation and biotesting, and efficient data processing…

  17. 19
    top 3.5%

    Paper-based fluorescence sensor array with functionalized carbon quantum dots for bacterial discrimination using a machine learning algorithm

    Fangbin Wang, Minghui Xiao, Jing Qi, Liang Zhu

    32 citationsOpen access (CC-BY)doi:10.1007/s00216-024-05262-4OpenAlex

    Show abstract

    Abstract The rapid discrimination of bacteria is currently an emerging trend in the fields of food safety, medical detection, and environmental observation. Traditional methods often require lengthy culturing processes, specialized analytical equipment, and bacterial recognition receptors. In response to this need, we have developed a paper-based fluorescence sensor array platform for identifying different bacteria. The sensor array is based on three unique carbon quantum dots (CQDs) as sensing units, each modified with a different antibiotic (polymyxin B, ampicillin, and gentamicin). These antibiotic-modified CQDs can aggregate on the bacterial surface, triggering aggregation-induced fluorescence quenching. The sensor array exhibits varying fluorescent responses to different bacterial species. To achieve low-cost and portable detection, CQDs were formulated into fluorescent ink and used with an inkjet printer to manufacture paper-based sensor arrays. A smartphone was used to collect the responses generated by the bacteria and platform. Diverse machine learning algorithms were…

  18. 20
    top 3.6%

    Electrochemical and biosensor techniques to monitor neurotransmitter changes with depression

    Kelly E. Dunham, B. Jill Venton

    32 citationsOpen access (CC-BY)doi:10.1007/s00216-024-05136-9OpenAlex

    Show abstract

    Depression is a common mental illness. However, its current treatments, like selective serotonin reuptake inhibitors (SSRIs) and micro-dosing ketamine, are extremely variable between patients and not well understood. Three neurotransmitters: serotonin, histamine, and glutamate, have been proposed to be key mediators of depression. This review focuses on analytical methods to quantify these neurotransmitters to better understand neurological mechanisms of depression and how they are altered during treatment. To quantitatively measure serotonin and histamine, electrochemical techniques such as chronoamperometry and fast-scan cyclic voltammetry (FSCV) have been improved to study how specific molecular targets, like transporters and receptors, change with antidepressants and inflammation. Specifically, these studies show that different SSRIs have unique effects on serotonin reuptake and release. Histamine is normally elevated during stress, and a new inflammation hypothesis of depression links histamine and cytokine release. Electrochemical measurements revealed that stress increases…

  19. 21
    top 3.8%

    Structural characterization and physicochemical properties of different hydrophilic natural deep eutectic solvents

    Laura Carbonell‐Rozas, Romina Canales, Roberto Romero‐González, María Fernanda Silva, Antonia Garrido Frenich

    31 citationsOpen access (OTHER-OA)doi:10.1007/s00216-024-05636-8OpenAlex

  20. 22
    top 4%

    PFAS ghosts: how to identify, evaluate, and exorcise new and existing analytical interference

    Jacqueline Bangma, Kitrina M. Barry, Christine M. Fisher, Susan A. Genualdi, Theresa C. Guillette and 7 more

    30 citationsOpen accessdoi:10.1007/s00216-024-05125-yOpenAlex

  21. 23
    top 4.2%

    Tailoring metal oxide nanozymes for biomedical applications: trends, limitations, and perceptions

    Parikshana Mathur, Mamta Kumawat, Rashi Nagar, Ragini Singh, Hemant Kumar Daima

    29 citationsdoi:10.1007/s00216-024-05416-4OpenAlex

  22. 24
    top 4.4%

    Generation of macro- and microplastic databases by high-throughput FTIR analysis with microplate readers

    Win Cowger, Lisa Roscher, Hannah Jebens, Ali Chamas, Benjamin Maurer and 3 more

    29 citationsOpen access (CC-BY)doi:10.1007/s00216-024-05127-wOpenAlex

    Show abstract

    FTIR spectral identification is today's gold standard analytical procedure for plastic pollution material characterization. High-throughput FTIR techniques have been advanced for small microplastics (10-500 µm) but less so for large microplastics (500-5 mm) and macroplastics (> 5 mm). These larger plastics are typically analyzed using ATR, which is highly manual and can sometimes destroy particles of interest. Furthermore, spectral libraries are often inadequate due to the limited variety of reference materials and spectral collection modes, resulting from expensive spectral data collection. We advance a new high-throughput technique to remedy these problems using FTIR microplate readers for measuring large particles (> 500 µm). We created a new reference database of over 6000 spectra for transmission, ATR, and reflection spectral collection modes with over 600 plastic, organic, and mineral reference materials relevant to plastic pollution research. We also streamline future analysis in microplate readers by creating a new particle holder for transmission measurements using…

  23. 25
    top 4.5%

    A critical review of wastewater-based epidemiology as a tool to evaluate the unintentional human exposure to potentially harmful chemicals

    Rodrigo B. Carneiro, Maria‐Christina Nika, Rubén Gil‐Solsona, Konstantina S. Diamanti, Νikolaos S. Τhomaidis and 2 more

    28 citationsOpen access (CC-BY)doi:10.1007/s00216-024-05596-zOpenAlex

    Show abstract

    Wastewater-based epidemiology (WBE) is a powerful tool to gather epidemiological insights at the community level, providing objective data on population exposure to harmful substances. A considerable portion of the human exposure to these potentially harmful chemicals occurs unintentionally, unlike substances such as pharmaceuticals, illicit drugs, or alcohol. In this context, this comprehensive review analyzes WBE studies focused on classes of organic chemicals to which humans are unintentionally exposed, namely organophosphorus flame retardants, per- and polyfluoroalkyl substances (PFAS), benzotriazoles and benzothiazoles, phthalates and terephthalates, benzophenones, pesticides, bisphenols, and parabens. The review highlights some advantages of WBE for public health surveillance, e.g., non-invasive analysis, predictive capability, nearly real-time data, population-wide insights, no ethical approval, and unbiased sampling. It also discusses challenges and future research directions in WBE regarding exposure to harmful chemicals from various sources. The review emphasizes the…

  24. 26
    top 4.7%

    Assessing human exposure to pesticides and mycotoxins: optimization and validation of a method for multianalyte determination in urine samples

    Jesús Marín‐Sáez, Maykel Hernández‐Mesa, Jose A. Gallardo-Ramos, Laura Gámiz‐Gracia, Ana María García-Campaña

    28 citationsOpen access (CC-BY)doi:10.1007/s00216-024-05191-2OpenAlex

    Show abstract

    Humans are exposed to an increasing number of contaminants, with diet being one of the most important exposure routes. In this framework, human biomonitoring is considered the gold standard for evaluating human exposure to chemicals. Pesticides and mycotoxins are chemicals of special concern due to their health implications. They constitute the predominant border rejection notifications for food and feed in Europe and the USA. However, current biomonitoring studies are focused on a limited number of compounds and do not evaluate mycotoxins and pesticides together. In this study, an analytical method has been developed for the determination of 30 pesticides and 23 mycotoxins of concern in urine samples. A salting-out liquid-liquid extraction (SALLE) procedure was optimized achieving recoveries between 70 and 120% for almost all the compounds and limits as lower as when QuEChERS was applied. The compounds were then determined by liquid chromatography coupled to triple quadrupole mass spectrometry. Different chromatographic conditions and analytical columns were tested, selecting a…

  25. 28
    top 5.1%

    A review of a colorimetric biosensor based on Fe3O4 nanozymes for food safety detection

    Ningning Guo, Jia Yang, Yixuan Li, Weiing Wang, Xiwen Liang and 3 more

    26 citationsdoi:10.1007/s00216-024-05679-xOpenAlex

  26. 30
    top 5.4%

    Non-target screening reveals 124 PFAS at an AFFF-impacted field site in Germany specified by novel systematic terminology

    Melanie Schüßler, Catharina Capitain, Boris Bugsel, Jonathan Zweigle, Christian Zwiener

    25 citationsOpen access (CC-BY)doi:10.1007/s00216-024-05611-3OpenAlex

    Show abstract

    The uncontrolled release of aqueous film-forming foam (AFFF) ingredients during a major fire incident in Reilingen, Germany, in 2008 led to significant soil and groundwater contamination. As the identity of fluorochemical surfactants in AFFF are often veiled due to company secrets, it is important to characterize AFFF contaminations and their impact on the environment comprehensively. In this study, we adapted a systematic approach combining a suitable extraction method with liquid chromatography high-resolution quadrupole time-of-flight mass spectrometry (LC-QTOF-MS) for an extensive non-targeted analysis. Our analysis identified 124 per- and polyfluoroalkyl substances (PFAS) from 42 subclasses in the contaminated soil (confidence levels of identification between 1 and 3). Typical for AFFF-impacted field sites, these included anionic, cationic, and zwitterionic substances with perfluoroalkyl chains spanning from 3 to 14 carbon atoms. Furthermore, we identified 1 previously unreported substance, and detected 9 PFAS subclasses for the first time in soil. AFFFs have long been employed…

  27. 31
    top 5.6%

    Synthesis and characterization of core–shell magnetic molecularly imprinted polymer nanocomposites for the detection of interleukin-6

    Rahil Radfar, Eda Akin, Ekin Sehit, Nastasia Sanda Moldovean‐Cioroianu, Niklas Wolff and 4 more

    24 citationsOpen access (CC-BY)doi:10.1007/s00216-024-05536-xOpenAlex

    Show abstract

    Abstract Interleukin-6 (IL-6) belongs to the cytokine family and plays a vital role in regulating immune response, bone maintenance, body temperature adjustment, and cell growth. The overexpression of IL-6 can indicate various health complications, such as anastomotic leakage, cancer, and chronic diseases. Therefore, the availability of highly sensitive and specific biosensing platforms for IL-6 detection is critical. In this study, for the first time, epitope-mediated IL-6-specific magnetic molecularly imprinted core–shell structures with fluorescent properties were synthesized using a three-step protocol, namely, magnetic nanoparticle functionalization, polymerization, and template removal following thorough optimization studies. The magnetic molecularly imprinted polymers (MMIPs) were characterized using dynamic and electrophoretic light scattering (DLS and ELS), revealing a hydrodynamic size of 169.9 nm and zeta potential of +17.1 mV, while Fourier transform infrared (FTIR) spectroscopy and fluorescence spectroscopy techniques showed characteristic peaks of the polymer and…

  28. 32
    top 5.8%

    Eco-friendly solvents in liquid–liquid microextraction techniques for biological and environmental analysis: a critical review

    Aldana A. Lemos, Agostina L. Chapana, Cecilia E. Luján, María B. Botella, Maria Natalia Oviedo and 1 more

    24 citationsdoi:10.1007/s00216-024-05578-1OpenAlex

  29. 33
    top 6%

    Molecularly imprinted nanogels as synthetic recognition materials for the ultrasensitive detection of periodontal disease biomarkers

    Thomas Hix‐Janssens, Julia R. Davies, Nicholas W. Turner, Börje Sellergren, Mark V. Sullivan

    24 citationsOpen access (CC-BY)doi:10.1007/s00216-024-05395-6OpenAlex

    Show abstract

    Periodontal disease affects supporting dental structures and ranks among one of the top most expensive conditions to treat in the world. Moreover, in recent years, the disease has also been linked to cardiovascular and Alzheimer's diseases. At present, there is a serious lack of accurate diagnostic tools to identify people at severe risk of periodontal disease progression. Porphyromonas gingivalis is often considered one of the most contributing factors towards disease progression. It produces the Arg- and Lys-specific proteases Rgp and Kgp, respectively. Within this work, a short epitope sequence of these proteases is immobilised onto a magnetic nanoparticle platform. These are then used as a template to produce high-affinity, selective molecularly imprinted nanogels, using the common monomers N-tert-butylacrylamide (TBAM), N-isopropyl acrylamide (NIPAM), and N-(3-aminopropyl) methacrylamide hydrochloride (APMA). N,N-Methylene bis(acrylamide) (BIS) was used as a crosslinking monomer to form the interconnected polymeric network. The produced nanogels were immobilised onto a planar…

  30. 34
    top 6.1%

    Nile red staining for rapid screening of plastic-suspect particles in edible seafood tissues

    Julia Süssmann, Elke Kerstin Fischer, Lars Hildebrandt, Elke Walz, Ralf Greiner and 2 more

    24 citationsOpen access (CC-BY)doi:10.1007/s00216-024-05296-8OpenAlex

    Show abstract

    Abstract Concerns regarding microplastic (MP) contamination in aquatic ecosystems and its impact on seafood require a better understanding of human dietary MP exposure including extensive monitoring. While conventional techniques for MP analysis like infrared or Raman microspectroscopy provide detailed particle information, they are limited by low sample throughput, particularly when dealing with high particle numbers in seafood due to matrix-related residues. Consequently, more rapid techniques need to be developed to meet the requirements of large-scale monitoring. This study focused on semi-automated fluorescence imaging analysis after Nile red staining for rapid MP screening in seafood. By implementing RGB-based fluorescence threshold values, the need for high operator expertise to prevent misclassification was addressed. Food-relevant MP was identified with over 95% probability and differentiated from natural polymers with a 1% error rate. Comparison with laser direct infrared imaging (LDIR), a state-of-the-art method for rapid MP analysis, showed similar particle counts,…

  31. 35
    top 6.3%

    Critical evaluation of the potential of ICP-MS-based systems in toxicological studies of metallic nanoparticles

    Sergio Fernández-Trujillo, María Jiménez-Moreno, Nuria Rodríguez Fariñas, Rosa Carmen Rodríguez Martín-Doimeadios

    24 citationsOpen access (CC-BY)doi:10.1007/s00216-024-05181-4OpenAlex

    Show abstract

    The extensive application of metallic nanoparticles (NPs) in several fields has significantly impacted our daily lives. Nonetheless, uncertainties persist regarding the toxicity and potential risks associated with the vast number of NPs entering the environment and human bodies, so the performance of toxicological studies are highly demanded. While traditional assays focus primarily on the effects, the comprehension of the underlying processes requires innovative analytical approaches that can detect, characterize, and quantify NPs in complex biological matrices. Among the available alternatives to achieve this information, mass spectrometry, and more concretely, inductively coupled plasma mass spectrometry (ICP-MS), has emerged as an appealing option. This work critically reviews the valuable contribution of ICP-MS-based techniques to investigate NP toxicity and their transformations during in vitro and in vivo toxicological assays. Various ICP-MS modalities, such as total elemental analysis, single particle or single-cell modes, and coupling with separation techniques, as well as…

  32. 36
    top 6.5%

    Spectrally separated dual-label upconversion luminescence lateral flow assay for cancer-specific STn-glycosylation in CA125 and CA15-3

    Miikka Ekman, Teppo Salminen, Kirsti Raiko, Tero Soukka, Kamlesh Gidwani and 1 more

    23 citationsOpen access (CC-BY)doi:10.1007/s00216-024-05275-zOpenAlex

    Show abstract

    Abstract Multiplexed lateral flow assays (LFAs) offer efficient on-site testing by simultaneously detecting multiple biomarkers from a single sample, reducing costs. In cancer diagnostics, where biomarkers can lack specificity, multiparameter detection provides more information at the point-of-care. Our research focuses on epithelial ovarian cancer (EOC), where STn-glycosylated forms of CA125 and CA15-3 antigens can better discriminate cancer from benign conditions. We have developed a dual-label LFA that detects both CA125-STn and CA15-3-STn within a single anti-STn antibody test line. This utilizes spectral separation of green (540 nm) and blue (450 nm) emitting erbium (NaYF 4 :Yb 3+ , Er 3+ )- and thulium (NaYF 4 : Yb 3+ , Tm 3+ )-doped upconverting nanoparticle (UCNP) reporters conjugated with antibodies against the protein epitopes in CA125 or CA15-3. This technology allows the simultaneous detection of different antigen variants from a single test line. The developed proof-of-concept dual-label LFA was able to distinguish between the ascites fluid samples from diagnosed…

  33. 37
    top 6.7%

    Towards a reference material for microplastics’ number concentration—case study of PET in water using Raman microspectroscopy

    Oliver Jacob, Elżbieta Anna Stefaniak, Seghers John, Rita La Spina, Gabriella F. Schirinzi and 6 more

    23 citationsOpen access (CC-BY)doi:10.1007/s00216-024-05251-7OpenAlex

    Show abstract

    Increasing demand for size-resolved identification and quantification of microplastic particles in drinking water and environmental samples requires the adequate validation of methods and techniques that can be used for this purpose. In turn, the feasibility of such validation depends on the existence of suitable certified reference materials (CRM). A new candidate reference material (RM), consisting of polyethylene terephthalate (PET) particles and a water matrix, has been developed. Here, we examine its suitability with respect to a homogeneous and stable microplastic particle number concentration across its individual units. A measurement series employing tailor-made software for automated counting and analysis of particles (TUM-ParticleTyper 2) coupled with Raman microspectroscopy showed evidence of the candidate RM homogeneity with a relative standard deviation of 12% of PET particle counts involving particle sizes >30 µm. Both the total particle count and the respective sums within distinct size classes were comparable in all selected candidate RM units. We demonstrate the…

  34. 38
    top 6.9%

    Introducing molecular imprinting onto nanozymes: toward selective catalytic analysis

    Zhijian Bu, Lian Huang, Shu Li, Qingzhen Tian, Zheng Tang and 4 more

    23 citationsdoi:10.1007/s00216-024-05183-2OpenAlex

  35. 39
    top 7%

    Multiplexed electrochemical liposomes applied to the detection of nucleic acids for Influenza A, Influenza B and SARS-CoV-2

    Florian Gerstl, Michael Loessl, Veronika Borggraefe, Antje J. Baeumner

    23 citationsOpen access (CC-BY)doi:10.1007/s00216-024-05145-8OpenAlex

    Show abstract

    Abstract Multiplexing is a relevant strategy for biosensors to improve accuracy and decision-making due to the increased amount of simultaneously obtained information. Liposomes offer unique benefits for label-based multiplexing since a variety of different marker molecules can be encapsulated, leading to intrinsic signal amplification and enabling a variety of detection formats. We successfully developed an electrochemical (EC) liposome-based platform technology for the simultaneous detection of at least three analytes by studying parameters to ensure specific and sensitive bioassay performance. Influenza A and B and SARS-CoV-2 sequences served as model system in a standard sandwich hybridization assay. Studies included encapsulants, probe distribution on liposomes and capture beads, assay setup and interferences between liposomes to also ensure a generalization of the platform. Ruthenium hexamine(III), potassium hexacyanoferrate(II) and m-carboxy luminol, when encapsulated separately into a liposome, provided desirable long-term stability of at least 12 months and no cross-signals…

  36. 40
    top 7.2%

    Enhancing sensitivity towards electrochemical miRNA detection using an affordable paper-based strategy

    Wanda Cimmino, Ada Raucci, Sara Pia Grosso, Nicola Normanno, Stefano Cinti

    22 citationsOpen access (CC-BY)doi:10.1007/s00216-024-05406-6OpenAlex

    Show abstract

    In the era of liquid biopsy, microRNAs emerge as promising candidates for the early diagnosis and prognosis of cancer, offering valuable insights into the disease's development. Among all the existing analytical approaches, even if traditional approaches such as the nucleic acid amplification ones have the advantages to be highly sensitive, they cannot be used at the point-of-care, while sensors might be poorly sensitive despite their portability. In order to improve the analytical performance of existing electroanalytical systems, we demonstrate how a simple chromatographic paper-based disk might be useful to rationally improve the sensitivity, depending on the number of preconcentration cycles. A paper-based electrochemical platform for miRNA detection has been developed by modifying a paper-based electrode with a methylene blue (MB)-modified single-stranded sequence (ssDNA) complementary to the chosen miRNA, namely miR-224 that is associated with lung cancer. A detection limit of ca. 0.6 nM has been obtained in spiked human serum samples. To further enhance the sensitivity, an…

  37. 41
    top 7.4%

    Evaluation of deep eutectic solvents in the synthesis of molecularly imprinted fibers for the solid-phase microextraction of triazines in soil samples

    Alexia Monnier, Myriam Díaz‐Álvarez, Esther Turiel, Antonio Martín‐Esteban

    22 citationsOpen access (CC-BY)doi:10.1007/s00216-024-05164-5OpenAlex

    Show abstract

    Abstract Nowadays, molecularly imprinted polymers (MIPs) are well established and are considered excellent materials for performing selective extractions. However, with the progressive implementation of the principles of green chemistry, it is necessary to find greener alternatives for both the synthesis and further use of MIPs in sample preparation. Accordingly, in the present work, different deep eutectic solvents (DES, both hydrophilic and hydrophobic), as an alternative to conventional organic solvents (i.e., toluene), were evaluated as porogens for the synthesis of imprinted fibers (monoliths), using fused silica capillaries as molds, for solid-phase microextraction (SPME). From this study, the polymer prepared with propazine (dummy template), methacrylic acid (monomer), ethylene glycol dimethacrylate (cross-linker), and a formic acid:L-menthol (1:1) DES (porogen) showed the best performance for selective rebinding of triazines. After optimization of the different variables involved in SPME, the new imprinted fibers were successfully applied to the extraction of target analytes…

  38. 42
    top 7.6%

    Non-targeted analytical comparison of a heated tobacco product aerosol against mainstream cigarette smoke: does heating tobacco produce an inherently different set of aerosol constituents?

    Gerhard Lang, Carlos Henao, Martin F. Almstetter, Daniel Arndt, Catherine G. Goujon-Ginglinger and 1 more

    22 citationsOpen access (CC-BY)doi:10.1007/s00216-024-05126-xOpenAlex

    Show abstract

    Smoking-related diseases remain a significant public health concern, and heated tobacco products (HTPs) have emerged as a potential alternative to cigarettes. While several studies have confirmed that HTP aerosols contain lower levels of harmful and potentially harmful constituents (HPHCs) than cigarette smoke, less is known about constituents that are intrinsically higher in HTP aerosols. This study provides a comprehensive comparative assessment of an HTP aerosol produced with Tobacco Heating System 2.2 (THS) and comparator cigarette (CC) smoke aiming at identifying all unique or increased compounds in THS aerosol by applying a broad set of LC-MS and GC × GC-MS methods. To focus on differences due to heating versus burning tobacco, confounding factors were minimized by using the same tobacco in both test items and not adding flavorants. Of all analytical features, only 3.5%-corresponding to 31 distinctive compounds-were significantly more abundant in THS aerosol than in CC smoke. A notable subset of these compounds was identified as reaction products of glycerol. The only compound…

  39. 43
    top 7.8%

    LC-ESI-HRMS — lipidomics of phospholipids

    Katharina M. Rund, Laura Carpanedo, Robin Lauterbach, Tim Wermund, Annette L. West and 3 more

    22 citationsOpen access (CC-BY)doi:10.1007/s00216-023-05080-0OpenAlex

    Show abstract

    Abstract Lipids are a diverse class of molecules involved in many biological functions including cell signaling or cell membrane assembly. Owing to this relevance, LC–MS/MS-based lipidomics emerged as a major field in modern analytical chemistry. Here, we thoroughly characterized the influence of MS and LC settings — of a Q Exactive HF operated in Full MS/data-dependent MS 2 TOP N acquisition mode — in order to optimize the semi-quantification of polar lipids. Optimization of MS-source settings improved the signal intensity by factor 3 compared to default settings. Polar lipids were separated on an ACQUITY Premier CSH C18 reversed-phase column (100 × 2.1 mm, 1.7 µm, 130 Å) during an elution window of 28 min, leading to a sufficient number of both data points across the chromatographic peaks, as well as MS 2 spectra. Analysis was carried out in positive and negative ionization mode enabling the detection of a broader spectrum of lipids and to support the structural characterization of lipids. Optimal sample preparation of biological samples was achieved by liquid–liquid extraction…

  40. 44
    top 7.9%

    Development of a high-throughput UHPLC-MS/MS method for the analysis of Fusarium and Alternaria toxins in cereals and cereal-based food

    Fabian Dick, Alena Dietz, Stefan Asam, Michael Rychlik

    21 citationsOpen access (CC-BY)doi:10.1007/s00216-024-05486-4OpenAlex

    Show abstract

    A QuEChERS (quick, easy, cheap, effective, rugged, and safe)-based multi-mycotoxin method was developed, analyzing 24 (17 free and 7 modified) Alternaria and Fusarium toxins in cereals via ultrahigh-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). A modified QuEChERS approach was optimized for sample preparation. Quantification was conducted using a combination of stable isotope dilution analysis (SIDA) for nine toxins and matrix-matched calibration for ten toxins. Quantification via a structurally similar internal standard was conducted for four analytes. Alternariol-9-sulfate (AOH-9-S) was measured qualitatively. Limits of detection (LODs) were between 0.004 µg/kg for enniatin A1 (ENN A1) and 3.16 µg/kg for nivalenol (NIV), while the limits of quantification were between 0.013 and 11.8 µg/kg, respectively. The method was successfully applied to analyze 136 cereals and cereal-based foods, including 28 cereal-based infant food products. The analyzed samples were frequently contaminated with Alternaria toxins, proving their ubiquitous occurrence.…

  41. 46
    top 8.3%
  42. 48
    top 8.7%

How to read this list

The cohort is every article, review and book chapter OpenAlex attributes to Analytical and Bioanalytical Chemistry with publication year 2024, excluding retracted works and paratext such as editorials and errata. The top 50 by citation count are listed; the percentile is the rank divided by the cohort size. 26 of the 50 entries have an abstract in OpenAlex. Counts were read on 29 October 2026 and will not be updated on this page, so a quoted rank stays verifiable. Full rules on the methodology page.

Other journals, same idea

Work with these 25 papers in Kahubi

  • The papers land in your library with their DOIs
  • Ask anything across all of them, with citations
  • Draft a literature review from the same sources

Free plan, no card. Your files stay private unless you share them.

Reading several of these?

Kahubi reads papers with you, keeps every citation traceable and drafts with sources you can check. Free plan, no card.