Most-cited articles · 2024
The 50 most-cited articles in Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment, 2024
Ranked by OpenAlex citation count on 29 October 2026, out of 946 eligible articles Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment published in 2024. Ranks are frozen; this page will not change. Number one, with 52 citations: The BM@N spectrometer at the NICA accelerator complex.
- Cohort
- 946 articles
- Listed
- Top 50 (5.3%)
- Open access
- 28 of 50
- Snapshot
- 2026-10-29
The most-cited 2024 articles in this journal cluster around detector and sensor development for particle and nuclear physics, with additional strength in neutron instrumentation and imaging. The top paper, "The BM@N spectrometer at the NICA accelerator complex" by Afanasiev, Agakishiev, Aleksandrov and colleagues, received 52 citations. Other highly cited works include characterization of analogue Monolithic Active Pixel Sensor test structures in a 65 nm CMOS process and the second gadolinium loading of Super-Kamiokande, alongside neutron imaging and detector readout studies.
Readers can use this ranking to see which 2024 papers attracted the most citations according to OpenAlex, out of 946 eligible articles. The list reflects citation activity rather than quality or importance, and citation counts may change over time.
Introduction written from the titles and abstracts on this list. Every figure below is the source.
Ask about these papers
Grounded in this list only, with sources.
- 1top 0.2%
The BM@N spectrometer at the NICA accelerator complex
S. Afanasiev, G. Agakishiev, E. Aleksandrov, I. N. Aleksandrov, Pavel Nikolaevich Alekseev and 25 more
52 citationsOpen accessdoi:10.1016/j.nima.2024.169532OpenAlex
- 2top 0.3%
Characterization of analogue Monolithic Active Pixel Sensor test structures implemented in a 65 nm CMOS imaging process
G. Aglieri Rinella, G. Alocco, M. Antonelli, Roberto Baccomi, S. Beolè and 25 more
29 citationsOpen access (CC-BY)doi:10.1016/j.nima.2024.169896OpenAlex
Show abstractHide abstract
Analogue test structures were fabricated using the Tower Partners Semiconductor Co. CMOS 65 nm ISC process. The purpose was to characterize and qualify this process and to optimize the sensor for the next generation of Monolithic Active Pixels Sensors for high-energy physics. The technology was explored in several variants which differed by: doping levels, pixel geometries and pixel pitches (10–25 μ m). These variants have been tested following exposure to varying levels of irradiation up to 3 MGy and 1 0 16 1 MeV n eq cm −2 . Here the results from prototypes that feature direct analogue output of a 4 × 4 pixel matrix are reported, allowing the systematic and detailed study of charge collection properties. Measurements were taken both using 55 Fe X-ray sources and in beam tests using minimum ionizing particles. The results not only demonstrate the feasibility of using this technology for particle detection but also serve as a reference for future applications and optimizations.
- 3top 0.4%
Second gadolinium loading to Super-Kamiokande
K. Abe, Christophe Bronner, Y. Hayato, K. Hiraide, K. Hosokawa and 25 more
26 citationsOpen access (CC-BY-NC)doi:10.1016/j.nima.2024.169480OpenAlex
Show abstractHide abstract
The first loading of gadolinium (Gd) into Super-Kamiokande in 2020 was successful, and the neutron capture efficiency on Gd reached 50%. To further increase the Gd neutron capture efficiency to 75%, 26.1 tons of Gd2(SO4)3⋅8H2O was additionally loaded into Super-Kamiokande (SK) from May 31 to July 4, 2022. As the amount of loaded Gd2(SO4)3⋅8H2O was doubled compared to the first loading, the capacity of the powder dissolving system was doubled. We also developed new batches of gadolinium sulfate with even further reduced radioactive impurities. In addition, a more efficient screening method was devised and implemented to evaluate these new batches of Gd2(SO4)3⋅8H2O. Following the second loading, the Gd concentration in SK was measured to be 333.5±2.5 ppm via an Atomic Absorption Spectrometer (AAS). From the mean neutron capture time constant of neutrons from an Am/Be calibration source, the Gd concentration was independently measured to be 332.7 ± 6.8(sys.) ± 1.1(stat.) ppm, consistent with the AAS result. Furthermore, during the loading the Gd concentration was monitored continually…
- 4top 0.5%
The energy-resolved neutron imaging instrument at the China spallation neutron source
Jie Chen, Chaoju Yu, Zhirong Zeng, Haibiao Zheng, Shengxiang Wang and 4 more
26 citationsdoi:10.1016/j.nima.2024.169460OpenAlex
- 5top 0.6%
Energy profile of laser Compton slant-scattering γ -ray beams determined by direct unfolding of total-energy responses of a BGO detector
L.X. Liu, H. Utsunomiya, G.T. Fan, H.H. Xu, Hong-Wei Wang and 16 more
26 citationsdoi:10.1016/j.nima.2024.169314OpenAlex
- 6top 0.7%
ALCOR: A mixed-signal ASIC for the dRICH detector of the ePIC experiment at the EIC
F. Cossio, B.R. Achari, N. Agrawal, Maxim Alexeev, Chiara Alice and 25 more
20 citationsOpen access (CC-BY)doi:10.1016/j.nima.2024.169817OpenAlex
Show abstractHide abstract
We present a mixed-signal ASIC , called ALCOR (A Low-power Chip for Optical sensor Readout), designed for the readout and digitization of signals from Silicon Photomultipliers (SiPMs) in the framework of the dual-radiator RICH (dRICH) detector of the electron–Proton/Ion Collider (ePIC) experiment at the Electron–Ion Collider (EIC). ALCOR features 32 channels arranged in an 8x4 matrix. The amplifier input stage is a low impedance current conveyor based on a regulated common-gate topology. The versatile front-end is able to work with positive or negative input polarity signals and includes four gain settings and two discriminators with 6-bit DAC programmable thresholds. Each channel also incorporates quad-buffered low-power TDCs based on analogue interpolation providing precise timestamping with a 25–50 ps time bin. ALCOR is designed in a 110 nm CMOS technology and the power consumption is about 10–12 mW per channel. The ASIC has been extensively tested in the laboratory standalone and coupled to different SiPM models to assess its functionality and performance. The results have been…
- 7top 0.8%
Development of the double spoke cavity prototype for CSNS-II
Wenzhong Zhou, Weimin Pan, Rui Ge, Feisi He, Jin Dai and 20 more
20 citationsdoi:10.1016/j.nima.2024.169170OpenAlex
- 8top 0.9%
Silicon Carbide devices for radiation detection: A review of the main performances
Salvatore S. Tudisco, C. Altana, S. Amaducci, C. Ciampi, Luigi Cosentino and 6 more
19 citationsdoi:10.1016/j.nima.2024.170112OpenAlex
- 9top 1%
Development of a high-yield compact D-D neutron generator
Xiaohou Bai, Jun Ma, Zhi-Yuan Wei, Jingying Wang, Xiaoxue Yu and 10 more
16 citationsdoi:10.1016/j.nima.2024.169993OpenAlex
- 10top 1.1%
TCAD modeling of radiation-induced defects in 4H-SiC diodes
Philipp Gaggl, Jürgen Burin, Andreas Gsponer, Simon Waid, Richard Thalmeier and 1 more
14 citationsOpen access (CC-BY)doi:10.1016/j.nima.2024.170015OpenAlex
- 11top 1.2%
Validation of Timepix4 energy calibration procedures with synchrotron X-ray beams
P. Delogu, N. V. Biesuz, R. Bolzonella, Luca Brombal, V. Cavallini and 6 more
14 citationsOpen access (CC-BY-NC-ND)doi:10.1016/j.nima.2024.169716OpenAlex
Show abstractHide abstract
The Timepix4 is an application-specific integrated circuit developed by the Medipix4 collaboration. The chip is a 448 × 512 matrix that can be connected, via bump-bonding, to pixelated sensors of various materials and thicknesses, forming application specific detection systems. Among the Timepix4 operating modes, the data-driven Time-of-Arrival - Time-Over-Threshold is a particularly promising mode for spectral imaging applications: data packets are generated every time the charge created by the incoming radiation goes above a pre-defined threshold, allowing the count of the detected particles and their energy measurement. This article investigates the spectroscopic characteristics of a Timepix4 assembly equipped with a 300 μm Si sensor, using monochromatic X-ray beams in the energy range 8.5 keV–40 keV working at the SYRMEP beamline of the Elettra synchrotron. The accuracy and the energy resolution of the reconstructed energy spectra, together with an energy resolution model, will be presented.
- 12top 1.3%
The first batch of compensated LGAD sensors
V. Sola, G. Paternoster, A. Morozzi, R. Arcidiacono, Mario Barozzi and 19 more
14 citationsOpen access (CC-BY)doi:10.1016/j.nima.2024.169453OpenAlex
Show abstractHide abstract
A new development of radiation-resistant silicon sensors is presented. The new sensors exploit the Low-Gain Avalanche Diode (LGAD) technology, with internal multiplication of the charge carriers, in combination with thin substrates, intrinsically less affected by radiation. An innovative design of the gain implant typical of the LGADs has been developed and fabricated, employing the compensation of acceptor and donor dopants to reproduce the effective acceptor doping dose of standard LGAD sensors. At the end of 2022, the Fondazione Bruno Kessler (Italy) delivered the first batch of compensated LGAD sensors on 30μm thick p-type epitaxial substrates. Electrical and transient characterisation of the sensors has been performed before and after irradiation up to 5 ⋅1015 1 MeV equivalent n/cm2. The ultimate goal is to develop and produce compensated LGAD sensors that can efficiently operate above fluences of 1017 1 MeV equivalent n/cm2.
- 13top 1.4%
LANTERN: A multichannel light calibration system for cryogenic detectors
G. del Castello
13 citationsOpen access (CC-BY-NC-ND)doi:10.1016/j.nima.2024.169728OpenAlex
Show abstractHide abstract
Recent advancements in low-energy rare-event searches rely on the use of cryogenic calorimeters in order to reach extremely low energy thresholds. When attempting to accurately characterize their responses within the region of interest (ROI) these detectors face severe challenges due to the fact that traditional radioactive calibration sources produce signals above the ROI and cannot be used in low background environments. LANTERN, an optical calibration system, can instead be used to accurately study the ROI of cryogenic detectors. It utilizes LED pulses to generate photon signals to perform detector calibration. LANTERN’s current LED matrix allows for a fast characterization of up to 64 calorimeters independently, spanning energies from a few eV to hundreds of keV. Its minimal electronics and optics make it a cost-effective and customizable solution and it will be employed by the BULLKID, NUCLEUS and CRAB experiments.
- 14top 1.5%
Systematic approach to measure the performance of microchannel-plate photomultipliers
Albert Lehmann, M. Böhm, M. Götz, K. Gumbert, Sebastian Krauß and 2 more
13 citationsOpen access (CC-BY-NC)doi:10.1016/j.nima.2024.169536OpenAlex
Show abstractHide abstract
In this paper, we present our approach to systematically measure numerous performance parameters of microchannel plate photomultiplier tubes . The experimental setups, the analyses and selected results are discussed. Although the techniques used may be different in other locations, the document is intended as a guide for comparable measurements with other types of microchannel plate photomultiplier tubes . Measurements are shown for the following performance parameters: spectral and spatial quantum efficiency , collection efficiency, gain as a function of voltage, position and magnetic field , time resolution, rate capability and lifetime. By using a dedicated 3-axis stepper and an FPGA-based data acquisition system, also inner PMT parameters are measured as a function of the active area, such as relative detection efficiency, dark count rate, time resolution, recoil electron and afterpulse distributions, as well as charge sharing and electronic crosstalk . In addition, some of the parameters are investigated inside a strong magnetic field . For many of these measurements, the…
- 15top 1.6%
Positronium lifetime measurement using a clinical PET system for tumor hypoxia identification
Sodai Takyu, Fumihiko Nishikido, Hideaki Tashima, Go Akamatsu, Ken‐ichiro Matsumoto and 2 more
13 citationsdoi:10.1016/j.nima.2024.169514OpenAlex
- 16top 1.7%
The DMAPS upgrade of the Belle II vertex detector
M. Babeluk, M. Barbero, J. Baudot, T. Bergauer, F. U. Bernlochner and 25 more
13 citationsOpen access (CC-BY-NC-ND)doi:10.1016/j.nima.2024.169428OpenAlex
- 17top 1.8%
Multi-energy in-vivo imaging of multiple contrast agents in a mouse using MPPC-based photon-counting CT
Daichi Sato, M. Arimoto, Ayumi Ishiguro, Fitri Lucyana, Takahiro Tomoda and 8 more
13 citationsOpen accessdoi:10.1016/j.nima.2024.169337OpenAlex
- 18top 2%
Determination of the neutron scattering contribution in a neutron calibration field based on MNSR
Afrouz Asgari, Seyed Abolfazl Hosseini, M.H. Choopan Dastjerdi, Javad Mokhtari
13 citationsdoi:10.1016/j.nima.2024.169154OpenAlex
- 19top 2.1%
Distillation and gas stripping purification plants for the JUNO liquid scintillator
Cecilia Landini, Marco Beretta, P. Lombardi, A. Brigatti, M. Montuschi and 25 more
12 citationsOpen access (CC-BY)doi:10.1016/j.nima.2024.169887OpenAlex
Show abstractHide abstract
The optical and radiochemical purification of the scintillating liquid which will fill the detector of the JUNO experiment plays a crucial role in achieving its scientific goals. Given its gigantic mass and dimensions, and an unprecedented target value of about 3 % at 1 MeV in energy resolution, JUNO has set severe requirements on the parameters of its scintillator, such as attenuation length (L at > 20 m at 430 nm), light yield, and content of radioactive contaminants ( 238 U, 232 Th < 10 -15 g/g). To accomplish these needs, the scintillator will be processed using several purification methods, including distillation under vacuum and gas stripping, carried out in two large-scale plants installed at the JUNO site. In this paper, the layout, operating principles, and technical aspects which have driven the design and construction of the distillation and gas stripping plants are reviewed. The distillation is effective in enhancing the optical properties and removing high-boiling radioactive impurities ( 238 U, 232 Th, 40 K), while the stripping process exploits pure water steam and…
- 20top 2.2%
RD53 pixel chips for the ATLAS and CMS Phase-2 upgrades at HL-LHC
F. Loddo, A. Andreazza, Fernando Arteche, M. Barbero, P. Barillon and 25 more
12 citationsdoi:10.1016/j.nima.2024.169682OpenAlex
- 21top 2.3%
Enhancing Coincidence Time Resolution of PET detectors using short-time Fourier transform and residual neural network
Amanjule Muhashi, Xuhui Feng, Yuya Onishi, Ryosuke Ota, Huafeng Liu
12 citationsdoi:10.1016/j.nima.2024.169540OpenAlex
- 22top 2.4%
Total ionizing dose measurements in small satellites in LEO using LabOSat-01
Lucas Finazzi, Mariano Barella, F. Gomez-Marlasca, Lucas Sambuco Salomone, S. Carbonetto and 5 more
12 citationsOpen access (CC-BY-NC-SA)doi:10.1016/j.nima.2024.169344OpenAlex
- 23top 2.5%
Design, optimization, and testing of ridge filters for proton FLASH radiotherapy at TRIUMF: The HEDGEHOG
David Roddy, C. Bélanger-Champagne, Sebastian Tattenberg, S. Yen, M. Trinczek and 1 more
12 citationsdoi:10.1016/j.nima.2024.169284OpenAlex
- 24top 2.6%
Double-layered beam shaping assembly design based on intelligent optimization method coupling neural network and genetic algorithm for BNCT
Bo Rong, Hongbing Song, Zhifeng Li, Lei Hu, Jie Wang and 4 more
12 citationsdoi:10.1016/j.nima.2024.169260OpenAlex
- 25top 2.7%
Evaluation of vertical alignment in carbon nanotubes: A quantitative approach
Ravi Prakash Yadav, Ilaria Rago, Francesco Pandolfi, Carlo Mariani, A. Ruocco and 3 more
12 citationsOpen access (CC-BY)doi:10.1016/j.nima.2024.169081OpenAlex
Show abstractHide abstract
An automated quantitative study of the alignment of vertically aligned carbon nanotubes (VA-CNTs) from scanning electron microscopy (SEM) images has been demonstrated. It is based on the fact that the image gradient (directional change in intensity or color) at every pixel in the image contains the information about the anisotropy at that particular pixel i.e., the local alignment is maintained in the orthogonal direction to the gradient. Structure tensor metrics are formulated demonstrating to be able to summarize the distribution of gradient directions within the neighborhood of any pixel within a two-dimensional domain (surface). An image analysis is presented that evaluates the alignment in desired regions of interest (ROIs) in SEM images of VA-CNTs. This method has been exploited to study the alignment of two different kinds of VA-CNTs: one grown via the thermal chemical vapor deposition (T-CVD) method and the second synthesized via the plasma enhanced chemical vapor deposition (PE-CVD) method.
- 26top 2.8%
Radiation characterization of SiPMs for HERD PSD
Yirong Zhang, Yaqing Liu, Jifeng Han, D. Y. Guo, Yongwei Dong and 4 more
11 citationsdoi:10.1016/j.nima.2024.170035OpenAlex
- 27top 2.9%
High power target for the High Brilliance Neutron Source
Johannes Baggemann, Thomas Gutberlet, Paul Zakalek, J. Wolters, Ulrich Rücker and 7 more
11 citationsOpen access (CC-BY)doi:10.1016/j.nima.2024.169912OpenAlex
Show abstractHide abstract
The High Brilliance Neutron Source (HBS) is a High-Current Accelerator-driven Neutron Source (HiCANS) under development at Jülich Centre for Neutron Science - Forschungszentrum Jülich. The unique specifications of the HBS require a neutron target with a high neutron emission able to operate in vacuum with a 70 MeV proton beam with 90 mA peak current and 1.6% duty cycle leading to an average thermal load of 100 kW. A tantalum target of 100 cm 2 irradiated area with an internal cooling structure which removes the heat quite homogeneously, provides a good compromise between low pressure and high heat transfer and ensures an homogeneous protons energy loss was designed and optimized by means of MCNP, CFD and FEM simulations. Such a target was successfully manufactured and its operational capability was demonstrated by operating it under a heat load of 1 kW cm −2 from an electron gun. • High power neutron target for high current accelerator-driven neutron source (HiCANS). • Tantal target for neutron generation at 70 MeV proton beam. • up to 1 kW cm −2 thermal heat dissipation from a…
- 28top 3%
Characterisation of the FBK EXFLU1 thin sensors with gain in a high fluence environment
Robert Stephen White, R. Arcidiacono, G. Borghi, M. Boscardin, N. Cartiglia and 16 more
11 citationsOpen access (OTHER-OA)doi:10.1016/j.nima.2024.169798OpenAlex
- 29top 3.1%
A novel 4H–SiC thermal neutron detector based on a metal-oxide-semiconductor structure
Xiangdong Meng, Yuncheng Han, Lei Ren, Lianxin Zhang, Chuan Peng and 6 more
11 citationsdoi:10.1016/j.nima.2024.169683OpenAlex
- 30top 3.2%
Enhancement of alpha/beta ratio in NaI:Tl,6Li neutron-gamma scintillators by rare earth co-doping
Zhihao Song, Jingkang Wang, Yufeng Tong, Yuhao Zhang, Qian Wang and 4 more
11 citationsdoi:10.1016/j.nima.2024.169451OpenAlex
- 31top 3.3%
Measurement of the photon detection efficiency of Hamamatsu VUV4 SiPMS at cryogenic temperature
R. Álvarez-Garrote, E. Calvo, Aritz Canto, J. I. Crespo-Anadón, C. Cuesta and 7 more
11 citationsOpen access (CC-BY-NC-ND)doi:10.1016/j.nima.2024.169347OpenAlex
Show abstractHide abstract
Liquid argon time projection chambers (TPC) are widely used in neutrino oscillation and dark matter experiments. Detection of scintillation light in liquid argon TPC’s is challenging because of its short wavelength, in the VUV range, and the cryogenic temperatures (∼86 K) at which the sensors must operate. Wavelength shifters (WLS) are typically needed to take advantage of the high Photon Detection Efficiency (PDE) in the visible range of most of photondetectors. The Hamamatsu VUV4 S13370–6075CN SiPMs can directly detect VUV light without the use of WLS, which main benefit is an improved PDE at these short wavelengths, but also the visible light from WLS. The manufacturer (Hamamatsu Photonics K.K.) provides a complete characterization of these devices at room temperature; however, previous studies have indicated a decrease of the PDE at cryogenic temperature for VUV light. In this work, we present the measurement of the PDE of VUV4 SiPMs at cryogenic temperature for different wavelengths in the range [270, 570] nm. A dedicated measurement at 127 nm is also shown.
- 32top 3.4%
High count rate gamma ray pile-up correction method of NaI(Tl) detector based on deconvolution method
Jingxin Zuo, Chaowen Yang, Weihao Shao, Lixin Bai, Yun Song and 2 more
11 citationsdoi:10.1016/j.nima.2024.169135OpenAlex
- 33top 3.5%
Characterization of a radiation detector based on opaque water-based liquid scintillator
J. Apilluelo, L. Asquith, E.F Bannister, J.L. Béney, Xavier de la Bernardie and 25 more
10 citationsOpen accessdoi:10.1016/j.nima.2024.170075OpenAlex
- 34top 3.6%
Growth and characterization of highly efficient Cs 3 Cu 2 I 5 single crystal for γ -ray detection
Bharti Bansal, V. Anand, G. Anil Kumar, V. Ranga
10 citationsdoi:10.1016/j.nima.2024.169867OpenAlex
- 35top 3.7%
Waveform simulation for scintillation characteristics of NaI(Tl) crystal
J.J. Choi, Chang Hyon Ha, E. J. Jeon, K.W. Kim, S.K. Kim and 8 more
10 citationsOpen access (CC-BY)doi:10.1016/j.nima.2024.169489OpenAlex
- 36top 3.9%
Experimental characterization of discrimination capabilities of EJ-276 and EJ-276G read by SiPM by pulse-shape analysis techniques
Emanuele Vincenzo Pagano, G. Politi, Adriana Simancas, E. De Filippo, P. Russotto and 16 more
10 citationsOpen access (OTHER-OA)doi:10.1016/j.nima.2024.169425OpenAlex
- 37top 4%
Compact HOM-damping structure of a beam-accelerating TM020 mode rf cavity
H. Ego, Hitoshi Nagata Tanaka, T. Inagaki, T. Ohshima, Hiroshi Yamaguchi and 3 more
10 citationsOpen access (CC-BY-NC-ND)doi:10.1016/j.nima.2024.169418OpenAlex
Show abstractHide abstract
A compact HOM-damping beam-accelerating rf cavity was developed to mitigate coupled-bunch instabilities in electron storage rings. This cavity operates in the TM020 mode, characterized by a high Q-value and a high shunt impedance. The new HOM-damping mechanism leverages the unique field distributions of the TM020 mode, allowing direct embedding of rf absorbing materials into the cavity body. This novel structure underwent validation through rf simulations and measurements using a model cavity resonating at 508.58 MHz in the TM020 mode with a shunt impedance of 6.8 MΩ and designed to have HOM impedances of less than 0.1 MΩ longitudinally and 0.5 MΩ/m transversely. We also fabricated and tested a prototype cavity, showcasing its HOM-damping efficacy and high-power functionality at 120 kW, generating an accelerating voltage of 900 kV. This prototype operated successfully at full power, confirming the viability of both the damping structure and its high-power application.
- 38top 4.1%
Design and optimization of a dedicated Faraday cup for UHDR proton dosimetry: Implementation in a UHDR irradiation station
Lucas Schoenauen, Richard Coos, Julien L. Colaux, Anne‐Catherine Heuskin
10 citationsdoi:10.1016/j.nima.2024.169411OpenAlex
- 39top 4.2%
Measurement of the electron–hole pair creation energy in a 4H-SiC p-n diode
Andreas Gsponer, Matthias Knopf, Philipp Gaggl, Jürgen Burin, Simon Waid and 1 more
10 citationsOpen access (CC-BY)doi:10.1016/j.nima.2024.169412OpenAlex
Show abstractHide abstract
For 4H silicon carbide (4H-SiC), the values for the electron–hole pair creation energy ϵ i published in the literature vary significantly. This work presents an experimental determination of ϵ i using 50 μ m 4H-SiC p-n diodes designed for particle detection in high-energy physics. The detector response was measured for α particles between 4 . 2 MeV and 5 . 6 MeV for 4H-SiC and a silicon reference device. Different α energies were obtained by using multiple nuclides and varying the effective air gap between the α source and the detector. The energy deposited in the detectors was determined using a Monte Carlo simulation , taking into account the device cross-sections. A linear fit of the detector response to the deposited energy yields ϵ i = ( 7 . 83 ± 0 . 02 ) eV , which agrees well with the most recent literature. For the 4H-SiC detectors, a linewidth of 28 keV FWHM was achieved, corresponding to an energy resolution of 0.5 %.
- 40top 4.3%
Development of a radioactive substance detection system integrating a Compton camera and a LiDAR camera with a hexapod robot
Yuki Sato, Takeshi Kakuto, Takayuki Tanaka, Hiroyuki Shimano, Yuko Morohashi and 3 more
10 citationsdoi:10.1016/j.nima.2024.169300OpenAlex
- 41top 4.4%
Development of a practical tritiated water monitor to supervise the discharge of treated water from Fukushima Daiichi Nuclear Power Plant
Yukihisa Sanada, Keisuke Oshikiri, Marina Kanno, Tomohisa Abe
10 citationsOpen access (CC-BY-NC-ND)doi:10.1016/j.nima.2024.169208OpenAlex
Show abstractHide abstract
As part of the Fukushima Daiichi Nuclear Power Plant (FDNPP) decommissioning, the release of stored treated water began in 2023. We developed a practical tritium monitor to continuously supervise the tritiated water concentration at FDNPP. The monitor contains a flow cell detector comprising plastic scintillator pellets and incorporating simultaneous measurements by three detectors, a veto detector, and lead shielding to reduce the influence of environmental γ rays. The system reached a detection limit of 593 Bq L−1 in 60 min, which is lower than the discharge standard for tritiated water of 1500 Bq L−1.
- 42top 4.5%
Optical simulation of the non-uniformity for the LYSO crystal of the HERD calorimeter
Penghui Wang, Xin Liu, Zhigang Wang, Ning Huang, Xingquan Liu and 5 more
10 citationsdoi:10.1016/j.nima.2024.169209OpenAlex
- 43top 4.6%
An intense source of very cold neutrons using solid deuterium and nanodiamonds for the European Spallation Source
N. Rizzi, B. Folsom, Mina Akhyani, Mads Bertelsen, P. Böni and 17 more
10 citationsOpen access (CC-BY-NC-ND)doi:10.1016/j.nima.2024.169215OpenAlex
- 44top 4.7%
Coincidence time resolution of 50 ps FWHM using a pair of multi-anode MCP-PMTs with Cherenkov radiator window
Lingyue Chen, Lishuang Ma, Guorui Huang, Zhehao Hua, Muchun Jin and 12 more
10 citationsdoi:10.1016/j.nima.2024.169173OpenAlex
- 45top 4.8%
Optimization of the Second Target Station cold source moderators using an automated workflow
Kristel Ghoos, Lukas Zavorka, J. Risner, Igor Remec
10 citationsOpen accessdoi:10.1016/j.nima.2023.169035OpenAlex
- 46top 4.9%
Miniaturised cooler-buncher for reduction of longitudinal emittance at IGISOL
V. Virtanen, T. Eronen, Anu Kankainen, O. Beliuskina, P. Campbell and 11 more
9 citationsOpen access (CC-BY)doi:10.1016/j.nima.2024.170186OpenAlex
Show abstractHide abstract
A new linear Paul trap section has been constructed to replace the existing bunching section of the radiofrequency quadrupole (RFQ) cooler-buncher at the IGISOL radioactive ion beam facility. The cooler-buncher is used to transform a continuous ion beam to temporally short bursts of ions. The new miniaturised cooler-buncher section produces significantly shorter bunches in time, required by the new Multi-Reflection Time-of-Flight Mass Spectrometer. In this article, we report on the longitudinal properties of the ion bunches and compare the results to an analytical model derived for axial distributions of ions confined in a harmonic trap at thermodynamical equilibrium with a heat bath. The new buncher configuration delivers <75ns full-width at half-maximum bunches with a longitudinal emittance of 200 eVns. The bunches have a full-width at half-maximum energy spread of 10 eV. Total transmission efficiency of 45%–65% has been measured from the isotope separator focal plane through the RFQ cooler-buncher, Multi-Reflection Time-of-Flight Mass Spectrometer and JYFLTRAP double Penning trap.
- 47top 5%
Monte Carlo and experimental assessment of the optimal geometry of the source and collimator for a table-top NRTA system for small nuclear material measurement
Cébastien Joël Guembou Shouop, H. Tsuchiya
9 citationsdoi:10.1016/j.nima.2024.170189OpenAlex
- 48top 5.1%
Preliminary Design of CSNS-II LINAC SRF LLRF based on C-ADS Injector I
Z.-P. Xie, Kai Guo, Zhencheng Mu, Hua Liu, Xinpeng Ma and 17 more
9 citationsdoi:10.1016/j.nima.2024.170131OpenAlex
- 49top 5.2%
Characterization of newly developed large area SiC sensors for the NUMEN experiment
D. Carbone, A. Spatafora, D. Calvo, F. Guerra, G. A. Brischetto and 5 more
9 citationsOpen access (CC-BY-NC-SA)doi:10.1016/j.nima.2024.169960OpenAlex
- 50top 5.3%
ATLAS ITk pixel detector overview
C. M. Buttar
9 citationsOpen access (CC-BY)doi:10.1016/j.nima.2024.169978OpenAlex
Show abstractHide abstract
In the high-luminosity era of the Large Hadron Collider, the instantaneous luminosity is expected to reach unprecedented values, resulting in up to 200 proton–proton interactions in a typical bunch crossing. To cope with the resulting increase in occupancy, bandwidth and radiation damage, the ATLAS Inner Detector will be replaced by an all-silicon system, the Inner Tracker (ITk). The innermost part of the ITk will consist of a pixel detector, with an active area of about 13 m 2 . To deal with the changing requirements in terms of radiation hardness, power dissipation and production yield, several silicon sensor technologies equipped with novel ASICs connecting by bump-bonding technique will be employed in the five barrel and endcap layers. As a timeline, it is facing to pre-production of components, sensor, building modules, mechanical structures and services. This contribution presents the status of the ITk-pixel project focusing on the lessons learned and the biggest challenges towards production, from mechanics structures to sensors, and it will summarise the latest results on…
How to read this list
The cohort is every article, review and book chapter OpenAlex attributes to Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment with publication year 2024, excluding retracted works and paratext such as editorials and errata. The top 50 by citation count are listed; the percentile is the rank divided by the cohort size. 16 of the 50 entries have an abstract in OpenAlex. Counts were read on 29 October 2026 and will not be updated on this page, so a quoted rank stays verifiable. Full rules on the methodology page.
Other journals, same idea
Work with these 25 papers in Kahubi
- The papers land in your library with their DOIs
- Ask anything across all of them, with citations
- Draft a literature review from the same sources
Free plan, no card. Your files stay private unless you share them.
Reading several of these?
Kahubi reads papers with you, keeps every citation traceable and drafts with sources you can check. Free plan, no card.